[Tutorial] DELTA MS300 VFD Setting

Поділитися
Вставка
  • Опубліковано 11 гру 2021
  • Guide for Setup DELTA MS300 VFD Internal & External Control
    Guide Link: plc247.com/delta-ms300-vfd-se...
    Please share and subscribe to the channel if you find it useful !

КОМЕНТАРІ • 33

  • @redpope4735
    @redpope4735 Рік тому +1

    Thank you. You save me the trouble for setting up my inverter at 3AM.. subscribed

  • @viveknarwal1230
    @viveknarwal1230 Рік тому

    Thanku so much..this video helps us at 1:00AM..really thanku.

  • @DavidRomeroGuillen
    @DavidRomeroGuillen 2 роки тому

    Thank you!

  • @omkarpadigela3915
    @omkarpadigela3915 Рік тому

    Thank you man. Thanks a lot

  • @dave21011
    @dave21011 4 місяці тому

    Hello. I am working on the same drive and unable to change any parameters it’s reading err can you help please thanks.

  • @NaveenKumar-jv1ww
    @NaveenKumar-jv1ww Рік тому

    Thank you gd information

  • @cerita-ceritanabi3343
    @cerita-ceritanabi3343 5 місяців тому

    Hi, thank you for you tutorial video. I have question, how to save our parameter setting? because when I turn of the inverter and turn on again, the inverter need setting again. Please help me to answer this question. Thank you

  • @mahaanvnath1146
    @mahaanvnath1146 11 місяців тому

    Is there any parameter for motor pole setting like for 2 pole and 4 pole

  • @SYNWorld-Life
    @SYNWorld-Life Рік тому

    Thank very much

  • @RafaelCardenas-oy1kb
    @RafaelCardenas-oy1kb 2 місяці тому

    HOLA DE NUEVO. COMO SE CONFIGURA PARA INVERTIR EL GIRO DESDE EL DISPLAY?...ESPERO SU PRONTA RESPUESTA.

  • @RafaelCardenas-oy1kb
    @RafaelCardenas-oy1kb 2 місяці тому

    HOLA. BUENAS NOCHES. MUY AGRADECIDO POR EL VIDEO TUTORIAL. PUEDO DECIR QUE YA PUEDO CONFIGURAR UN VDF. EN EL CASO DEL SELECTOR CUALES SON LOS PUNTOS DE CONEXION EN LAS BORNERAS DEL VDF. COMO CONECTO EN LAS BORNERAS PARA UN PULSADOR ENCENDIDO Y APAGADO. ESPERO SU PRONTA RESPUESTA...SALUDOS

  • @brilloestelar1
    @brilloestelar1 Рік тому

    Thank you very much for this video. I have a Delta MS300 VFD. I would like ask you a question. Does this VFD supports two different configurations? For example, a configuration (let's call it SETUP1) with the frequency 50Hz, acceleration time 5sec and deceleration time 2sec, and another configuration (let's call it SETUP2) with the frequency 30HZ, acceleration 10sec and deceleration 10sec. After that, could I access each of the configurations according to my needs? Thank you very much again and greetings from Spain. Sorry my English is not good.

    • @felipeamici3376
      @felipeamici3376 Рік тому +1

      Fiz essa aplicação com multspeed em uma esteira alimentadora avança com 30 hz 875rpm e retorna com 60hz 1750rpm fazendo reversão ao retornar

  • @andy32218
    @andy32218 2 роки тому

    I could use your help. If I factory reset the vfd will it still communicate with the plc or do I need to change parameters?

    • @plc247automation6
      @plc247automation6  2 роки тому

      When you factory reset the VFD, you will need to reconfigure the communication parameters

  • @kidsanimazione4933
    @kidsanimazione4933 Рік тому +1

    Hello, i change the VDF EXTERNAL CONTROL.
    00.20 by 2 to 9. NOW when i put it at 2 it call error… do you know why?

  • @eliasmoralvag
    @eliasmoralvag 2 роки тому

    Hello, thank you very much for your tutorial, I think it's an easy question.
    How could I set the minimum frequency with the potentiometer to be 50hz and the maximum 90hz? ??
    Thank you

    • @user-yw9py6ui3n
      @user-yw9py6ui3n Рік тому

      Set parameter 1 - 10 to 90, and paramter 1-11 to 50

  • @Ajitkumar-bb3wz
    @Ajitkumar-bb3wz 2 роки тому

    vfd 4a8ms21ansaa hai kya
    model

  • @corrosiontechnologies6213
    @corrosiontechnologies6213 10 місяців тому

    Hello - I have an MS300, a 2 pole 10HP, 11.7Amp induction motor. I cannot get the motor to turn over 240 rpm at 60Hz. I am using the internal pot for control. What could be limiting this? Could the motor be hooked up wrong? I have the max frequency set at 60Hz. I should be able to get 3400 or more rpm out of this motor.

    • @corrosiontechnologies6213
      @corrosiontechnologies6213 10 місяців тому +1

      Okay, we called the electrician back in that wired the motor. They had it wired for 230v and not 460v. Wired correctly and we are running fine.

  • @mitsubishielectricautomati4776
    @mitsubishielectricautomati4776 2 роки тому +1

    👍 🙏 💞

  • @ravirajjadhav8237
    @ravirajjadhav8237 Рік тому

    Hz kam Jada ho Rahi hai bht motor chalu nahi ho rha hai push butan se key pad se chal rha hae

  • @131200fantasma2dj
    @131200fantasma2dj Рік тому

    Hola amigo puse la configuración que indicas en tu video en uno de mis variadores de frecuencia arranca bien pero en el instante en que se para sale un anuncio en la pantalla que dice oud y ahí se queda sin hacer nada como si se parara en seco o brusco o desacelera pero hice todo lo que muestra en su video

  • @kishanpal5456
    @kishanpal5456 4 місяці тому

    rpm parameter

  • @piratesofcarribean4211
    @piratesofcarribean4211 Рік тому

    is this 3 phase