Thank you! Amazing work! Here the contactor is after the breaker but in previous videos it’s different - they are the other way around. Can you explain which system works better in each scenario?
Great product presentation, again. However, I notice 32 relay channels with contactors tend to become quite noisy. Any sollutions for that in the future? Are these relay boards also planned with a zigbee antenna or do you already have these?
Hey KinCony! I know it's probably obvious, but is there a reason we use a fuse instead of a circuit breaker? I'm quite new but would like to understand the design choice. Thanks! :D
Thank you! I am glad your making nice products and I have noticed your English getting better year over year. I used the 868COLB for a customer and it worked good ! System design with manual failover is very good idea! I like the small power meter rings.
Hi, can you please inform that how the wiring of a home is to be done as per your schema of DBs. As in South East Asia, Generally a single CB, controls a single room. In that sense, how should we go about thses type of DBs.
you can make one DB, all wire connect with one DB. Or you can make multi DBs, every floor or every room use by a small DB, such as 8 channel or 16 channel version.
If I understood correctly, there are two redundancies: the A32 Pro software being broken where the manual switch can be used to trigger the contactor and the contactor itself if the A32 Pro dies or the DC PSU dies. Is this correct?
Your work explanation very very great🎉🎉🎉
thanks
Best explanation 👏🏻!! Upload daily video sir I'm waiting for your new video's 😊
thanks.
The best company I ever seen in wired automation...pls make Tuya + Home assistant devices...also pls introduce a solution like KNX DALI system..
yes, in furture we will consider about Dali.
Thank you! Amazing work! Here the contactor is after the breaker but in previous videos it’s different - they are the other way around. Can you explain which system works better in each scenario?
this one is better.MCB before contactor.
i noticed that too.. my setup is breakers after contactors. 😅 tho it works great with H32B pro
Great product presentation, again. However, I notice 32 relay channels with contactors tend to become quite noisy. Any sollutions for that in the future? Are these relay boards also planned with a zigbee antenna or do you already have these?
if use SSR without any noise. do you want zigbee relay board work with home assistant?
@@KinCony yes that would be awesome
@@Dylan_Lanckman ok, thanks for suggestion
The new CT clamps look very good. What’s the max rating? Are they factory calibrated or should we calibrate them individually at arrival?
not need calibrate , there are some different model of CT sensor, MAX support 100A version.
Hey KinCony! I know it's probably obvious, but is there a reason we use a fuse instead of a circuit breaker? I'm quite new but would like to understand the design choice. Thanks! :D
fuse only protect the DC12v power supply.others load all protect by breakers.
Thank you! I am glad your making nice products and I have noticed your English getting better year over year. I used the 868COLB for a customer and it worked good ! System design with manual failover is very good idea! I like the small power meter rings.
thanks, sorry, my English also is poor:)
Very good. I liked kincony products ❤
@@lionlion-g9d thanks
Can you make a smaller energy meter? 10 or even 5 channel?
yes, will make it in furture
Hi, can you please inform that how the wiring of a home is to be done as per your schema of DBs.
As in South East Asia, Generally a single CB, controls a single room. In that sense, how should we go about thses type of DBs.
you can make one DB, all wire connect with one DB. Or you can make multi DBs, every floor or every room use by a small DB, such as 8 channel or 16 channel version.
what is the reason for using dc contactors?
Will not generate interference signals and cause interference to other devices
Does the DC contactor work manually if the DC power supply dies?
it should work..
sure, this is important
If I understood correctly, there are two redundancies: the A32 Pro software being broken where the manual switch can be used to trigger the contactor and the contactor itself if the A32 Pro dies or the DC PSU dies. Is this correct?
@@ruimarinho yes, you are right.
Why you dont use less mcb for lights.
You dont need to put for every output own mcb
yes, that will save space, good idea , some channels together with one MCB.
What’s the primary reason for using DC powered contactors?
DC contactor will not cause interference
Can you make EC PH control kits for sale? Bro
use for agriculture?