very well nicely explained ,but the only thing is since 1965 , when Pakistan shifted to SI units , psig for pressure is not being used kindly shift to bar or Pascal's
Thanks Dear brother for your valuable comments ❤️, Actually the problem is in my training institute is here no pressure gauge is available which has the pressure scale in Bar or Pa, 🙏🙏
Second question.. Kya 134 k compressor oil flush kar ka r600 charge karny ka baad ampere Mai Kuch farq paray ga... Aur performance Mai? 134 ka compressor ziyda power Wala hota r600 ka compressor ka muqabalay mai
@@Leo021_02 G zaror Bhai, R600a Ka compressor current km consume karta R-134a ke muqable,,, Performance Kabhi improve hoti hai Kabhi same rehti hai...ye depends karta hai unit ki capacity pr,,, Agar chote r134a ke refrigerator me r600a ko replace karte hai,,,tho performance improve hoti hai, jabke bade refrigerator me r134a ko replace Karne se aksar performance same rehti hai
R600 ki gas deep freezer Mai Dali normal temperature kaha tak ajata hai ? Mery deep freezer Mai last -14 tak Aya hai. Koi bataye ga normal Kitna ajata hai r600 ki gas per
@@FKmechofficial indoor ko on karne k baad outdoor kuch minutes baad start hota h shyad 3 minutes baad ..Lekin kyu hota h itna late koi toh wajah hogi ...
@@shonababu.1 yes brother. Outdoor late islie start hota hai taaake isss se pehle ek to indoor sensors ye check karta hai ke kiya ambient temp ke mutabiq compressor chalana zarori hai ke nhi, to jab sensor garmi Yani high temp: sense karta hai to ye tab compressor ko run karta hai. 2sri chiz ye ke jab AC chalte huwe stop ho Jaye, to dobara ON hone pe compressor Ka direct start hona teek nhi hota. Kyunke usss waqt condenser me already high pressure hota hai jis pr compressor fauri start nhi Le Sakta. Islie compressor ko 3 minutes late start kiya jata hai taaaake tab tk condenser awr evaporator coil me pressure equal ho Jaye awr compressor ke discharge pe pressure normal ho jaye to pir compressor easily start ho sakta hai. Thanks
@@FKmechofficial 🙏 wow...mene kaafi logo se pucha lekin sb logo k jawab se satisfy nhi hua lekin apke se ho gya thanks ... 1 sawal aur outdoor ka jo fan hota h wo kis direction me ghoomta h clockwise ya anti clockwise
@@shonababu.1 brother thanks for your valuable feedback. Outdoor fan clockwise bhi hosakta hai Awr anti clockwise bhi, Different designated ACs me design ke mutabiq clockwise or anti clockwise hote hain. But zyada tr anti clockwise hote hain
Aoa farman bahi kamal ki video ha ye ap ki concept clear kar kiya ha is video n
Thanks Dear Sir ❤️
Very usefull video. Refregeration working system clear. ♥️♥️♥️
Masha allah ustad umair.shaikh from hyd sindh
Shukarya Janab ❤️
Very well deep knowledge
Thanks
Respect from india, thanks dear
You are welcome Dear
Very informative
Thanks Dear brother ❤️
Mashallah brother good job 💐💐💐
Shukarya Bhai ❤️
Good information Sir
Thanks
is tarah se aaj tak kisi ne nahi sikhaya
Thanks Dear
Very nicely explained 😊 thank u
You are welcome Dear ❤️
Very well explained sir..
Thanks Dear ❤️
👍🙏
Thanks Dear brother for your valuable comments ❤️
very well nicely explained ,but the only thing is since 1965 , when Pakistan shifted to SI units , psig for pressure is not being used
kindly shift to bar or Pascal's
Thanks Dear brother for your valuable comments ❤️,
Actually the problem is in my training institute is here no pressure gauge is available which has the pressure scale in Bar or Pa,
🙏🙏
Farman sir lpg gas K bary me video banao fridge me recharged krna thek hn y nahi
Yes Dear very soon Insha Allah
Bhai mainy ap sa puchna ha es main paip kitna laghy gha waporatrr or condenser ka kitna kitna paip ho gha
1/4 dia wala tube hai,
Evaporator 36 ft
Condenser 48 ft
Please sir what refrigerant are you using for the diagram
R-134a refrigerant
Sir 134a ka compressor Mai oil change kar ka flush system kar ka r600 charge karsakty hain?reply
Yes of course oil bilkul saaf daal kr Achi vacuum kr Len...awr r600a charge kr Len...
Second question.. Kya 134 k compressor oil flush kar ka r600 charge karny ka baad ampere Mai Kuch farq paray ga... Aur performance Mai? 134 ka compressor ziyda power Wala hota r600 ka compressor ka muqabalay mai
@@Leo021_02 G zaror Bhai, R600a Ka compressor current km consume karta R-134a ke muqable,,,
Performance Kabhi improve hoti hai Kabhi same rehti hai...ye depends karta hai unit ki capacity pr,,,
Agar chote r134a ke refrigerator me r600a ko replace karte hai,,,tho performance improve hoti hai, jabke bade refrigerator me r134a ko replace Karne se aksar performance same rehti hai
@@FKmechofficial is topic per bhi video banaye ga takay information Sab ko mily aur apki video ka views bhi ziyda ho
@@Leo021_02 Ok Dear Sir ❤️
R600 ki gas deep freezer Mai Dali normal temperature kaha tak ajata hai ? Mery deep freezer Mai last -14 tak Aya hai. Koi bataye ga normal Kitna ajata hai r600 ki gas per
-18C tk Jana chahye ,,, agar gas liquid me charge ki ho
@@FKmechofficial -16.5 degree thermometer Mai agya hai. 12 hr running kar ka . Ya result 134 ka compressor Mai r600 charge karny per Aya hai
@@Leo021_02 ye bilkul perfect result hai bhai
Kuch puch skta hu apse ?
Yes Dear brother,
Any time most welcome
@@FKmechofficial indoor ko on karne k baad outdoor kuch minutes baad start hota h shyad 3 minutes baad ..Lekin kyu hota h itna late koi toh wajah hogi ...
@@shonababu.1 yes brother.
Outdoor late islie start hota hai taaake isss se pehle ek to indoor sensors ye check karta hai ke kiya ambient temp ke mutabiq compressor chalana zarori hai ke nhi, to jab sensor garmi Yani high temp: sense karta hai to ye tab compressor ko run karta hai.
2sri chiz ye ke jab AC chalte huwe stop ho Jaye, to dobara ON hone pe compressor Ka direct start hona teek nhi hota. Kyunke usss waqt condenser me already high pressure hota hai jis pr compressor fauri start nhi Le Sakta. Islie compressor ko 3 minutes late start kiya jata hai taaaake tab tk condenser awr evaporator coil me pressure equal ho Jaye awr compressor ke discharge pe pressure normal ho jaye to pir compressor easily start ho sakta hai.
Thanks
@@FKmechofficial 🙏 wow...mene kaafi logo se pucha lekin sb logo k jawab se satisfy nhi hua lekin apke se ho gya thanks ...
1 sawal aur outdoor ka jo fan hota h wo kis direction me ghoomta h clockwise ya anti clockwise
@@shonababu.1 brother thanks for your valuable feedback.
Outdoor fan clockwise bhi hosakta hai Awr anti clockwise bhi,
Different designated ACs me design ke mutabiq clockwise or anti clockwise hote hain.
But zyada tr anti clockwise hote hain