Refrigerator Capillary Replace || 0.028" by 0.031"

Поділитися
Вставка
  • Опубліковано 16 жов 2024
  • Refrigerator Capillary Replace || 0.028" by 0.031"
    Refrigerator Capillary Tube calculation,
    refrigerator condenser calculation,
    refrigerator evaporator Calculation,
    how to resize refrigerator Capillary Tube, Condenser & Evaporator,
    how to resize condenser,
    how to resize evaporator,
    how to resize capillary tube,
    Some Important video Links....
    Different Capillary Tubes Vs TXV valve || Effects of capillary Tube size increasing or decreasing
    • Capillary Tubes Vs TXV...
    R600a Vs R134a Electrical Power Consumption
    • R600a Vs R134a Electri...
    Auto Mobile Air Compressor || Complete Information about auto Mobile Air Compressor
    • Video
    Leak Detection Device for Freon Refrigerants || Leakage Tracing Easily
    • Leak Detection Device ...
    Refrigerant recovery information || How to recover Refrigerant 134a from refrigerator.
    • Refrigerant recovery i...
    Thanks for visit my UA-cam channel " FK mech official "

КОМЕНТАРІ • 100

  • @MehmoodRifaqat
    @MehmoodRifaqat 22 дні тому +1

    amazing content ! I wish I could give this video a thousand likes.

  • @DanishAli-mf4ly
    @DanishAli-mf4ly 10 місяців тому +1

    جزاکم اللہ خیرا

  • @obaidish
    @obaidish 10 місяців тому +3

    Very nice video sir thanks..

  • @prakashgotame8875
    @prakashgotame8875 10 місяців тому +3

    Good information sir

  • @mo.mubashshir3400
    @mo.mubashshir3400 10 місяців тому +1

    Assalmu alaikum farman bhai and
    Dear sir good information thank u

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      You are welcome Dear Mubashir Sir ❣️

  • @mahmad1897
    @mahmad1897 4 місяці тому +2

    سبحان الله
    ما شاء الله

  • @azmathussain8232
    @azmathussain8232 10 місяців тому +2

    Aoa bht hi informative video ha

  • @ImranaKhanam-e7h
    @ImranaKhanam-e7h 10 місяців тому +1

    Very good information 👍

  • @refrigeration-ac-technician
    @refrigeration-ac-technician 10 місяців тому +1

    MashaALLAH very informative video, sir Water dispenser jis me 1/8 ka compressor ho uski capillary ka pressure drop kitna hona chahye ?

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      Water cooler me water ko about10⁰C ya 5⁰C tk cool Karna parta hai,,, islie capillary tube Ka pressure drop 150 ~ 160 Psig rakha jata hai

    • @refrigeration-ac-technician
      @refrigeration-ac-technician 10 місяців тому +1

      @@FKmechofficial JazakAllah Sir, Aap kon se City me hote hen ??

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      @@refrigeration-ac-technician me brother Government Technical College Ghazi Haripur me HVAC Lecturer hon ...
      Awr Taxila me Gar hai.

    • @refrigeration-ac-technician
      @refrigeration-ac-technician 10 місяців тому +1

      @@FKmechofficial Sir Aap ka contact number mil Sakta he kabi Aap se koi advice leni ho tou

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      @@refrigeration-ac-technician +92 3059126576 yes brother, 24/7 apki khidmat me banda hazir

  • @SomeTech16
    @SomeTech16 4 місяці тому +2

    Is k last part mein jo aap keh rahay hein back pressure kum hota hay yeh thk hay by method but real mein back pressure barh jata ha

    • @FKmechofficial
      @FKmechofficial  4 місяці тому +1

      Ok Dear

    • @SomeTech16
      @SomeTech16 4 місяці тому

      Sir G abhi kaam zyada ha Banda aik Hoon har refrigerator ki caplary block ha China usa 134 mix charge Kar raha Hoon lekan 16 18 back pressure araha ha kaam ka Maza Ni araha pls suggest some!

    • @azeemtanveer2508
      @azeemtanveer2508 3 місяці тому

      Jnb agr capllary ka pressure droop brhayen gy to yani 200se 270 tk to temperature hamara upar jaega ya niche aaega

  • @mukhtarahmad9857
    @mukhtarahmad9857 3 місяці тому +1

    Very information sir

  • @mo.mubashshir3400
    @mo.mubashshir3400 10 місяців тому +1

    Kya 25 feet pipe laga sakte or 30 +30 feet pipe laga sakte h or single capillary ki jagah 3 capillary laga sakte h
    To compressor pr kuch effect padega

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      Bhai Jan me apke question ko sahih samajh nhi paya, but I think apke sawal ka jawab ye hai ke condenser ke pipe ka length tora sa zyada rakna hota hai evaporator ke pipe se.
      Awr refrigerator me capillary tube single lagana chahye,
      Jabke AC me capillary tubes ka 1 SE zyada lagana useful hota hai. Isss se compressor pr load barhta nhi

  • @Dispalycake
    @Dispalycake 2 місяці тому +1

    Miduam temp me capallary drop pressure kya hona chahaia...0tep ke lia

    • @FKmechofficial
      @FKmechofficial  2 місяці тому

      Brother refrigerator purpose ya air conditioning purpose

  • @mohammadsohailshaikh8373
    @mohammadsohailshaikh8373 Місяць тому +1

    Aasallamalekum sar inverter refrigerator 200liters inverter compressor is Ke liye caipalary kitane Ki our kitane ki feet R600Gas plz riplai duva Me yaad rakhe

    • @FKmechofficial
      @FKmechofficial  Місяць тому

      Wa Alaikumussalam,
      12ft awr 031 capillary tube

  • @Rehmanali-y2f
    @Rehmanali-y2f 6 місяців тому +1

    Aslam o aleekum sir r600 k compressor ko kitni capalary lagti h or us ka pressure kitna hona chahiyy or pressure r600 k compressor sy check krna chahiyy ya r134 k compressor sy compressor r600 ka lagana ho to

    • @FKmechofficial
      @FKmechofficial  6 місяців тому +1

      Brother, R600A kelie capillary tube ka pressure 210 psi tk hona chahye,
      Dusre compressor se bhi kar sakte hain

  • @SajjadAhmad-z1v2p
    @SajjadAhmad-z1v2p 4 місяці тому +1

    السلام علیکم سر سر میرے پاس ایک ڈبل ڈور نو فرا اور اس کو میں نے کمپریسر چینج کروایا اس کا کنڈینسر بھی گرم ہوتا ہے کمپریسر بھی گرم ہوتا ہے اور وہ کولنگ بہت کم کرتا ہے پلیز اپ کوئی ریکوائرمنٹ کر دیں مہربانی

    • @FKmechofficial
      @FKmechofficial  4 місяці тому

      Ap brother, WhatsApp pr Ajaye
      0305-9126576

  • @parveztirandaz9291
    @parveztirandaz9291 2 місяці тому +1

    Asalamo walekum sir mai india maharastra bombay se hu 134 ka pressur drop deep frezzar ke liye 600 ltr hai kitna hoga aur double capallery pahale lagae hai frezzar me 2 compartment kiye hai capallery size 0*40 ×2×8feet sahi hai compressor caj 415 hai (pdf aveleble in google) agar isme R410ka 1/2 hp compressor lagana hai to pressur drop kitna rakhna chahiye compressor (EMBRACO NEU4140GK) hai sir

    • @FKmechofficial
      @FKmechofficial  2 місяці тому

      Brother ye required temp: pr depends karta hai unit,
      Apke unit ka required temp: kiya hai

  • @saeedkiyani8431
    @saeedkiyani8431 3 місяці тому +1

    Sir single door fridge he uski caplary choke ho gye he mene 0.28 5 feet dali he lekin plate sif thandi ho rhi he ice ni a rhi he compressor TL 2.5a laga howa he kia problem ho gi..?

  • @DanishAli-mf4ly
    @DanishAli-mf4ly 10 місяців тому +1

    السلام علیکم سر
    سرجی یہ جو ڈی سی انورٹر فریج ائی ہیں ان کے بارے میں بھی کائنڈلی ہمیں گائیڈ کیجئے

    • @FKmechofficial
      @FKmechofficial  10 місяців тому +1

      Zaror Insha Allah, bs koshish hai ke ye course aik khas tarteeb se ho.
      Thanks for your valuable suggestions ❣️

  • @AnandMishra-tj7zz
    @AnandMishra-tj7zz 7 місяців тому +1

    Sir capillary ka pressure drop ac me bhi 200 se 250 tak hoga kya

    • @FKmechofficial
      @FKmechofficial  7 місяців тому

      No Dear, ye refrigerator ke capillary Ka limit hai

  • @kartikmalakar
    @kartikmalakar 10 місяців тому +1

    Sir ager new capillary maximum niche kitne tak aana chahiye??? 220 se kitne kam ane me chal jayegah?

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      200 se niche nhi hona chahye, agar ap ne refrigerator me freezing karni ho bhai

    • @kartikmalakar
      @kartikmalakar 10 місяців тому +1

      @@FKmechofficial tq sir❤️

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      @@kartikmalakar Ok Dear ❤️

    • @kartikmalakar
      @kartikmalakar 10 місяців тому +1

      @@FKmechofficial sir apka WhatsApp namber milegi?

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      @@kartikmalakar +92 3059126576

  • @mohdzaidqureshi5917
    @mohdzaidqureshi5917 10 місяців тому +1

    Mashallah

  • @mo.mubashshir3400
    @mo.mubashshir3400 10 місяців тому +1

    Isliy soloned valve ki baat puch raha hu jabki inverter refrigerator me e magnetic valve aati h jisme capillary ki valve ko band kr data h to Kya ye ho sakta h

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      No brother, Solenoid valve ki jaga pressure regulator valve best hai

    • @mo.mubashshir3400
      @mo.mubashshir3400 10 місяців тому

      @@FKmechofficial sir pressor regulator valve kese hoti h or non inverter compressor pr b work kregi Kya uski pic b mil sakti h

  • @fakharhayat5344
    @fakharhayat5344 6 місяців тому +1

    sir jb frigde gas full ho jy to guage py kitna pressure show hota hai

    • @FKmechofficial
      @FKmechofficial  6 місяців тому

      Brother ye ambient temp pe depend karta hai, 8 Psig se 12 Psig

  • @qaisarshahzad272
    @qaisarshahzad272 10 місяців тому +1

    MashAllah

  • @mo.mubashshir3400
    @mo.mubashshir3400 10 місяців тому +1

    Dear sir me ek steel body me 500 ltr ka deep freezer bana raha hu jisme 200 ltr dudh k liy ek tank or 180 ltr k liy dusra tank or niche dahi ya makkhan rakne k liy refrigerator h 120 ltr ka me ye chahta hu k teeno tank ka temperature me set kr k valve k saath jis tank ka hm temperature set kre wo tank utne temperature pr stop ho jay

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      G Bhai,
      Iske liye pressure regulator valve lagane parte hain,
      Wo HR aik tank ko required flow provide karenge

    • @Trushaenterprise
      @Trushaenterprise 6 місяців тому +1

      ❤​@@FKmechofficial

    • @FKmechofficial
      @FKmechofficial  6 місяців тому

      @@Trushaenterprise G

  • @ghulamfareed2233
    @ghulamfareed2233 Місяць тому +1

    Window ya split ac ka bhi same tarika he

    • @FKmechofficial
      @FKmechofficial  Місяць тому

      @@ghulamfareed2233 wo different pressure pe set hote hain bhai

  • @AnandMishra-tj7zz
    @AnandMishra-tj7zz 7 місяців тому +1

    Very nice vedio

  • @razziabdulrazzaq3969
    @razziabdulrazzaq3969 2 місяці тому +1

    اگر کیپلری ریٹرن کے اندر یا مکمل ساتھ آتی تو کیپلری کی ہیٹ کی وجہ سے ریٹرن جلدی نہ آتی گیس بھی اور ڈلتی اور کولنگ بھی اس سے کافی بہتر ہوتی

  • @AzmatKhan-d2n
    @AzmatKhan-d2n 5 місяців тому +1

    Wow good

  • @mo.mubashshir3400
    @mo.mubashshir3400 10 місяців тому +1

    Or hm solonoyed valve se koi bhi circuit band kr de jese 30 feet or 25 feet to Kya kaam krega

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      Solenoid valve refrigerator me lagana useful nhi hai

  • @MuhammadAsif-xz1ch
    @MuhammadAsif-xz1ch 6 місяців тому +1

    سر جی آپ نے جس کمپریسر سے پریشر ڈراپ کیا اس کا پریشر اور جو اندر لگا اس کا ڈراپ پریشر سیم نہیں ہو سکتا . جو کمپریسر لگانا یا جو لگا ہوا ہے اس کے حساب سے کپلری کا پریشر ڈراپ کروانا چاہیے

    • @FKmechofficial
      @FKmechofficial  6 місяців тому

      Bilkul brother,
      You are right but me ne just procedure samjha Diya tha

  • @inspirefridgesolution8848
    @inspirefridgesolution8848 6 місяців тому +1

    Sir mai 10 ft dalne se be -18c tak aa jata hai aur be sirf 1 ghante mai sir

    • @FKmechofficial
      @FKmechofficial  6 місяців тому

      Starting me 10 ft, 12ft, 14ft teek rehta hai

    • @FKmechofficial
      @FKmechofficial  6 місяців тому

      But long duration kelie pressure drop ke zariye length select Karna chahye

  • @arsumghazi7791
    @arsumghazi7791 6 місяців тому +1

    Sir cap gauge kitny ki or kaha sy Mily ge

  • @azmatullah7164
    @azmatullah7164 10 місяців тому +1

    Good

  • @razziabdulrazzaq3969
    @razziabdulrazzaq3969 2 місяці тому +1

    سر فریج کو پھاڑنے سے بہتر نہیں کہ ہم اسی کیپلری 028 کو فلیش کرتے اور کام بھی اوریجنل رہتا کیپلری بلاک بھی ہو تو کھولنے کی کوشش کرو

    • @FKmechofficial
      @FKmechofficial  2 місяці тому

      Brother blockage 2 tarah ki hoti hai.
      1- permanent block
      2- Temporary ya oil block
      Agar temporarily blockage ho wo to wash karne se good ho jaye gi,
      Pr permanent blockage ki surat me capillary tube ko hi change karna chahye

  • @omhri853
    @omhri853 9 місяців тому +1

    Most

  • @shabbirahmed5166
    @shabbirahmed5166 8 місяців тому +1

    nive work ustad

    • @FKmechofficial
      @FKmechofficial  8 місяців тому

      Thanks Dear brother for your valuable comments

  • @FakharZaman-fv7rb
    @FakharZaman-fv7rb 10 місяців тому +1

    اسلام علیکم جناب آپ کا نمبر درکار ہے مہربانی

    • @FKmechofficial
      @FKmechofficial  10 місяців тому +1

      Wa Alaikumussalam Sir ❤️
      WhatsApp +92 3059126576

  • @mo.mubashshir3400
    @mo.mubashshir3400 10 місяців тому +1

    Sir shayad me apni problem explain nhi kr pa raha hu

    • @FKmechofficial
      @FKmechofficial  10 місяців тому

      Dear Mubashir apke question ko me ne teek tarah se samajh nhi paya, Sorry 🙏

  • @usmansaleem6483
    @usmansaleem6483 7 місяців тому +1

    Bhai Kam to acha kr li kro

    • @FKmechofficial
      @FKmechofficial  7 місяців тому

      Sorry, brother.
      What is wrong here ?
      Can you please guide me ?