What to do When Your Septic Alarm is Going Off

Поділитися
Вставка
  • Опубліковано 4 жов 2024

КОМЕНТАРІ • 112

  • @baltajan
    @baltajan 5 років тому +6

    Thank you for taking the time to share your industry knowledge with us.
    Much respect

    • @cairopablo6505
      @cairopablo6505 3 роки тому

      i know it is pretty off topic but does anyone know a good website to stream newly released series online ?

    • @majorrhys9729
      @majorrhys9729 3 роки тому

      @Cairo Pablo I would suggest flixzone. Just google for it :)

    • @grahammario6370
      @grahammario6370 3 роки тому

      @Cairo Pablo I would suggest flixzone. You can find it by googling =)

  • @breeze787
    @breeze787 4 роки тому +2

    Thanks for putting this up. What made this video worthwhile is your explanation of how to test the floats. I didn't realize that its just a matter of continuity. Good stuff thanks!

  • @frankvonrossum7454
    @frankvonrossum7454 Рік тому

    Really appreciate the information you put out… Just moved into a neighborhood who has an aerobic system, I am informative with septic systems, but not aerobic systems, appreciate the information you put out…
    Thank you in advance!
    Frank von Rossum USCG Retired

  • @chuckstubblefield5998
    @chuckstubblefield5998 4 роки тому +7

    First turn power off to septic then Check air filter in agitator pump ( air pump). Most are located on top under the brick block house. . Filters are to cleaned every 6 months.. Most wont tell anyone this, not sure why. If breather element is too dirty that blocks air flow causing diaphragm to go out. Which stops putting out air , causing red light to come on due to no pressure on air pressure switch. There is a pressure switch in electric septic box panel. if that does not have pressure red light will come on as stated above.... God bless

  • @jimmywells33
    @jimmywells33 4 роки тому +1

    Thanks so much for sharing your knowledge and offering your time via phone.

  • @raidernation7203
    @raidernation7203 5 років тому +11

    Good video! I didn’t know that Kip from Napoleon Dynamite worked on septic.

  • @JasonTylerRicci
    @JasonTylerRicci 4 роки тому +2

    My Liberty Pumps alarm went off. First time I've ever heard it (besides testing it). I'm nervous I may have a failure somewhere. Thanks to your video, I can at least (somewhat) troubleshoot the issue

    • @RCworstwater
      @RCworstwater  4 роки тому +1

      Happy to hear! Thanks for watching

  • @romand123
    @romand123 5 років тому +3

    Thanks for shedding some light on this topic. Much appreciated!

  • @williamadams9318
    @williamadams9318 5 років тому +7

    Great job. I wanted to add a couple of things (wastewater was one of my studies). Chlorine (for those systems) can also be an alarm item. Overflow (especially from overnight) from a toilet (or toilets) flapper malfunction then morning routine water use added can flood a system and send an alarm. As well as simple electrical outage or breaker trip (storm lightning, pump over heat from continuous over use), etc. , etc.. Investigation effort can save money! A tech. must be paid to come out, even if it's a tripped breaker. A person who is a property owner, should take a class on wastewater. It's cheaper over the lifetime of the property to buy an education, rather than pay a technical authority. Most of these systems will need almost nothing for a single lifetime, IF they are maintained regularly. It's like the roof on your home. Maintaining is cheaper than replacement. AND some waste company's have monthly insurance type policy covering the entire system.

    • @ElonMuskX
      @ElonMuskX 2 роки тому

      Thanks, Will let everyone know when it is all good to go and the Sh*t will flow.

  • @robtheisen5844
    @robtheisen5844 5 років тому +3

    Fabulous video! You got me excited when you said you would be doing more in-depth videos about how the panel works and how to troubleshoot it. Yes please! Knowledge is power.
    Chris, I almost forgot to mention.... I just checked the awesome meter, looks like you’ve moved up from and 8 to a 9. Getting more awesome by the day!

  • @jessicaleerandall
    @jessicaleerandall 2 роки тому

    Wow-thank you so much. I searched, RSJ Rhombus and this is the first video. Very educational.

  • @mikemason4792
    @mikemason4792 5 років тому +1

    Great video. We are about to get our system install. You have given me as good understanding and now I know enough to ask specific question. Thank you.

  • @tyg5421
    @tyg5421 3 роки тому +2

    As a professional pump mechanic I can tell you videos like this help consumers understand the basic mechanics of their system good stuff . Any questions feel free to ask .

    • @paodigger644
      @paodigger644 3 роки тому

      Why is the red light blinking?

    • @tyg5421
      @tyg5421 3 роки тому

      @@paodigger644 hi Jeff
      If the light is blinking it can be two things power supply issue or you have a short in the line . Is it red or green blinking line ?

    • @paodigger644
      @paodigger644 3 роки тому

      Red. And tt so much for your time

    • @paodigger644
      @paodigger644 3 роки тому

      The toilets are flushing fine. It only does it when it rains.

    • @tyg5421
      @tyg5421 3 роки тому

      @@paodigger644 that means you have a short in the offset line going from your house to the pump chamber . Do you have a junction box where the wires go? If so open it up and see if the connections are ok and also if there is water in the box . If you don’t have a electrical box the wire is allowing water to make contact causing the red light to blink on and off and also do you buzzer on normal position

  • @amarilysrivera6318
    @amarilysrivera6318 4 роки тому +2

    Thank for sharing your knowledge with us. Help a lot!!

  • @gilles888
    @gilles888 Рік тому +1

    Very good video, my issue is that the alarm goes off for approx 10 sec max and goes off immediately and I can hear the pump going on and off, but after spending a few minutes I realized that the alarm start before the pump going off……Any ideas why ?

  • @Six_Deuce
    @Six_Deuce 5 років тому

    Thanks for this vid, The part about manual mode after taking off the other plug saved me, Our tank was clogged for a while, and our flexible pvc fitting bust off after putting it in manual mode, but I fixed it all up by slowly put the pump on manual mode and unplugging it and I think it got it all working, called the warranty ppl just to make sure.

  • @mamamumma1041
    @mamamumma1041 5 років тому +2

    Great video !! The best one I’ve seen yet!

  • @fangorn1000
    @fangorn1000 5 років тому +1

    Thank you for the video. It's very helpful.

  • @michaelmcgovern7870
    @michaelmcgovern7870 Рік тому

    Thank you for the video. Unplugging the piggy back switch seemed to work for our tank. I could hear the water moving and the red warning light went off. How long should I leave it unplugged?

  • @DiligentProsperous
    @DiligentProsperous 2 роки тому

    Thank you this was extremely helpful for me today.

  • @robertoflorendo7956
    @robertoflorendo7956 9 місяців тому

    What kind of control panel do you recommend for 1 residential pump single phase or do I need one? Thanks.

  • @papajswife5007
    @papajswife5007 3 місяці тому

    Just had a quick clean out. The alarm is going off. Looks like water level in tank is low. How do we correct that?

  • @MexSag1
    @MexSag1 3 роки тому

    Very helpful!!! Was able to troubleshoot myself 👊🏻

  • @99AUDI99
    @99AUDI99 Рік тому

    I have "Tank Alert" alarm, my septic tank overflow without alarm goes off today? Should I replace pump?

  • @1Y2ae
    @1Y2ae 2 роки тому

    Great video. My alarm went off and won’t silence when I press the button. I have a concrete 3 tank system. First tank for solids look pretty much 90% full. Second tank is like 75% full with, the water level is a few inches below where the water flows to the third tank. The tank with the float is only like 60% full. Not sure if I have a pump because I don’t have any raised mounds on my property. Any suggestions

  • @shawncockrell6007
    @shawncockrell6007 5 років тому +3

    Another outstanding detailed well presented video !

  • @wallyirizarry7092
    @wallyirizarry7092 4 роки тому +2

    Why the alarm would go off after the tank was pumped out during a regular maintenance check. Water is below the pump level and the alarm does not turn of even when I flip switch to manual? This is the first time happened, the pump was working that day and the next day I heard the buzz sound coming from the tank and I could not shut it off, ended up unplugging the relay inside the box.

    • @RCworstwater
      @RCworstwater  4 роки тому

      Sounds like you may have a bad float or splice.

    • @wallyirizarry7092
      @wallyirizarry7092 4 роки тому

      @@RCworstwater Now that the water level is up to the first float the alarm is not going off anymore. It is strange. I will keep an eye on the system.(it looks like is a Delta Environmental Pentair Water system UC-60 model)Thank you for your advice.

  • @skelecaster
    @skelecaster 3 роки тому

    In a basement waste pump system, does any water from upper levels drain to the basement tank? Alarm goes off even when nobody is in basement bathroom for days. Laundry is on main level. Thanks.

  • @FourthRiverJoint
    @FourthRiverJoint 4 роки тому

    This was really helpful thanks! My alarm went off and I assumed it was high water, but found that it was actually low. I let it fill and tested the pump and that worked, but the light won't go off at all. I do not have a control box and I have tried unplugging it and switching the breaker. Any idea on how to get it to reset?

    • @RCworstwater
      @RCworstwater  4 роки тому

      Where is the alarm switch mounted in the tank?

  • @lynn.williams1930
    @lynn.williams1930 4 роки тому +8

    I was home alone when this started going off so I literally went army style😎
    Thank you for helping me to stop thinking I was about to die x

  • @muslodeplaga
    @muslodeplaga 4 роки тому +1

    thanks excellent video ..

  • @CreateNowSleepLater
    @CreateNowSleepLater 10 місяців тому

    My alarm was going off and I got it pumped. The alarm just came back on but this time the red light is out. What does that mean? Is it just time? Oddly enough, the alarm sound is very light. its strange.

  • @ambarbahadurrajak5745
    @ambarbahadurrajak5745 2 роки тому

    Excellent video !!!

  • @HungNguyen-sb1yu
    @HungNguyen-sb1yu Рік тому

    Can I wire that alarm button to a WiFi switch so I can turn the alarm off remotely. My alarm goes off every time we have power outage, many times in the middle of the night. Thank you.

  • @franklempka2159
    @franklempka2159 3 роки тому

    Just Re hooked up alarm box after relocating after down for two weeks and alarm is going off so maybe go manual till tank is normal?

  • @fourshuz
    @fourshuz 4 роки тому +2

    Thank you for the video. Can I ask a question. I do have a person coming out on Wednesday, but this is a 2 year old system, and the third time we are having an issue with the alarm, the last time one month ago, we spent $600 to replace a float and relocate the floats to the opposite end to avoid further issue, and the alarm went off again. I manually drained the pump as soon as the alarm was going off, so I am not able to see if the issue was that it was high and not draining automatically, but i do know that the pump is working when I hit it manually. But when I drained it manually, before I dug it back up (it is 4 inches under the grass), the alarm never turned off, even when the box was emptied down to the bottom. Does this mean there is an issue with the float alarm?

    • @fourshuz
      @fourshuz 4 роки тому

      He would like to replace the box (for $2000).

  • @seanmiller8661
    @seanmiller8661 2 роки тому

    What can I do if water back feeds from my front yard flooding

  • @uhhmanduhh12386
    @uhhmanduhh12386 3 роки тому

    What do you do if the alarm button does not silence the alarm? And unplugging and plugging it back in doesn't silence it?

  • @caseybubke3406
    @caseybubke3406 4 роки тому +1

    Ace On the House brought me here.

  • @dustinberns5143
    @dustinberns5143 4 роки тому

    My septic company came out yesterday switched the skim and main line and tested something this way but never switched back main to main skim to skim line on pump box alarm went off .I feel like theyre going to not tell me the truth or damages that it can cause as its there fault oh skim lines in main. And main lines not connected at all.

  • @luisflores8929
    @luisflores8929 Рік тому

    Hello, I got a zoeller that has two pumps. When I put it in manual it’ll pump the water but not on automatic. Would you recommend to simply replace both pumps or should I involve an electrician to test float switch?

    • @RCworstwater
      @RCworstwater  Рік тому +1

      If it pumps in manual and not automatic then you have a problem with your floats.

  • @bthemedia
    @bthemedia 3 місяці тому

    Could also be fuse in the panel that died and needs to be replaced.

  • @terrapreta1
    @terrapreta1 4 роки тому +1

    I'm not hearing a horn but there is a soft chirping sound every so often. What might this indicate? The warning light is not on either.

    • @RCworstwater
      @RCworstwater  4 роки тому +1

      The chirping could indicate a low battery or a bad connection (such as water in the splice box)

    • @terrapreta1
      @terrapreta1 4 роки тому

      @@RCworstwater Thank you! I'll check that out!

  • @danwesson1934
    @danwesson1934 2 роки тому

    Is it possible ours went off because the toilet hung and was trying to fill the tank all night ?

  • @beckiwildeman600
    @beckiwildeman600 4 роки тому

    the drain in the shower is slow and I began to wonder what is going on and I went down stairs to check and the tanks are not even lit on. What the heck? I have two alert stations neither is on. Can't even figure how to turn them on.

  • @ElonMuskX
    @ElonMuskX 2 роки тому

    What would cause a slight back feed of electricity to my light and alarm on the high water alarm?

    • @RCworstwater
      @RCworstwater  2 роки тому +1

      Water in the splice box or a bad splice connection/float switch

    • @ElonMuskX
      @ElonMuskX 2 роки тому

      @@RCworstwater Checking more on that today. Thanks

  • @spencersuxx
    @spencersuxx 4 роки тому

    Best video I've seen on the subject. Thank you ! We just had our pump and float replaced and now one week later our alarm is going off again. The water level is normal, we don't have a control panel just the float and alarm

  • @eliovisita
    @eliovisita Рік тому

    What if I have sewer instead of septic

  • @rmwolfe6938
    @rmwolfe6938 4 роки тому

    How do you replace the light bulb on the red light??

    • @RCworstwater
      @RCworstwater  4 роки тому +1

      That would depend on the model. Probably best to give the OEM a call.

  • @Huntr24
    @Huntr24 Рік тому

    Lucas sent y’all here lol

  • @DerekEvan
    @DerekEvan 2 роки тому

    My red light is just faintly on with no siren sound. What does that mean? Tank is less than half full.

    • @RCworstwater
      @RCworstwater  2 роки тому

      Most likely you have water in the splice in the splice box.

    • @DerekEvan
      @DerekEvan 2 роки тому

      @@RCworstwater that makes a lot of sense. If only I could find the splice box darn it.

  • @nld-bl5ct
    @nld-bl5ct 5 років тому

    I wish I had an alarm. How do I get them installed?

    • @RCworstwater
      @RCworstwater  5 років тому

      You can order one at Rcworst.com and call a local septic company to come install it.

    • @nld-bl5ct
      @nld-bl5ct 5 років тому +1

      @@RCworstwater I have a septic tank and the old style leach tank or pit. I just had both pumped. They are 10' under the ground with risers. The leach pit is open now. Is it easy to install while the pit is open?

  • @debbiecombscampbell5551
    @debbiecombscampbell5551 2 роки тому

    Mine is saying high current

  • @natetolbert3671
    @natetolbert3671 4 роки тому +1

    This is funny. Our alarm light has been on for years now. I just found out it was an alarm yesterday. We always thought it was a power light. No wonder we're always having to plunge the fking toilet!

    • @RCworstwater
      @RCworstwater  4 роки тому +2

      Better late than never! Time to get that fixed

  • @TK-setophaga
    @TK-setophaga 4 роки тому +1

    I like your videos and learned much. The earing should go however.

  • @sherryblackburn946
    @sherryblackburn946 3 роки тому

    If I silenced my alarm but didn't notice anything wrong by the time we opened the tank, will it go off again if the problem persists? The water was not high.

    • @RCworstwater
      @RCworstwater  3 роки тому

      Did the light turn off? If the light is still on then there's still an issue to address.

  • @matthewnovik4050
    @matthewnovik4050 Рік тому

    do floats ever not float?

  • @jungobungo327
    @jungobungo327 4 роки тому +3

    Thanks Chris! You’re the worst! 😁😁

  • @paodigger644
    @paodigger644 3 роки тому

    Why is the red light blinking?

    • @RCworstwater
      @RCworstwater  3 роки тому

      You likely have a high water alarm condition

    • @paodigger644
      @paodigger644 3 роки тому

      The toilets are not the backing up. Do you think I need to dig up the top to look inside to check the water level?

    • @RCworstwater
      @RCworstwater  3 роки тому

      Yes. Usually the alarm float is under the same lid as your pump and there should be a riser on it so you don't have to dig it up. If there's no riser I would highly recommend you put one on it so you're not digging every time the system needs serviced.

  • @albion2742
    @albion2742 2 роки тому

    $200 more, like $500-600 with the filter change where I live.

  • @claudiodominguez.
    @claudiodominguez. 3 місяці тому

    It's a crappy situation.

  • @jtang63
    @jtang63 4 роки тому

    my service guy would bring a submersible pump to pump out the water.

  • @whylogicalthinking
    @whylogicalthinking 2 роки тому

    I’m guessing he’s Canadian…

  • @jotarokujo3961
    @jotarokujo3961 5 років тому +2

    *why. would. you. have. a. sewer. alarm.*

    • @jotarokujo3961
      @jotarokujo3961 5 років тому

      *e p i c*

    • @sethholland3807
      @sethholland3807 4 роки тому +4

      So you know when your septic tank is about to overflow. It causes serious issues that are pretty nasty. Just gives you a warning so you can get someone to pump your septic tank. They’re more common in rural areas

    • @whylogicalthinking
      @whylogicalthinking 2 роки тому

      Why would you be this stupid

  • @nuckinfutz1270
    @nuckinfutz1270 2 місяці тому +1

    I can’t understand why these people create excessively long videos. Get to the point man and quit rambling.

  • @demetriusjohan5899
    @demetriusjohan5899 4 роки тому +4

    Romans chapter 10 verse nine if you declare with your mouth Jesus is Lord and believe in your heart that God raised him from the dead the Bible says you will be saved