[Hindi] Why Inverter Increase Electricity Bill? Battery Charging Power Consumption Units/Watts Test
Вставка
- Опубліковано 23 сер 2024
- You Might have Heard that Electricity Bill goes up after Inverter is Installed at home.
How does that happen? And how much Power does an Inverter or UPS use to Fully Charge a Solar battery? Let's test it, Live!
This Video is available in Multiple Languages-
English- • [Eng] Why Inverter Inc...
Hindi- • [Hindi] Why Inverter I...
This Video is about-
1. Why Inverters Increase your Electricity Bill upon Installation.
2. Inverter battery Charging Efficiency
3. Inverter Power Loss. Power wastage in Inverter Battery systems.
4. How many Units Inverter use to charge Solar battery
5. Higher Monthly & Yearly Utility bills due to Inverter constant consumption.
#Microtek800VA #ZenInnovations #ZenHindi #GreenEnergy #AllAboutBatteries #EfficiencyTest #SolarEnergy #PowerLoss #SaveEnergy #PowerConsumptionTest
[Playlists]
Do check my Complete Solar Playlist-
• Solar Energy
Power Consumption Test Playlist-
• Power Consumption Testing
Members-Only Videos-
• Members-only videos
[Important Related Videos]
Can we use Car Battery for Inverter? | Whats Difference between Tubular & Automotive Battery?[Hindi]
• Can we use Car Battery...
UTL Gamma plus QnA EP1 (Hindi & English) | FAQ and discussion on Solar PCU MPPT 1KVA 12v Inverter.
• UTL Gamma plus QnA EP1...
UTL Gamma Plus Idle Draw (Self Consumption) Testing and proof
12V Model Idle draw- • UTL Gamma Plus Idle Dr...
24V Model Idle Draw- • 24V UTL Gamma Plus Idl...
Inverter Self Consumption is from Mains or Battery ? Solar PCU Idle draw detailed test [Hindi]
• Inverter Self Consumpt...
What is Inside Microtek Sinewave Inverter
English- • [Eng] How Sinewave Inv...
Hindi- • [Hindi] How Sinewave I...
UTL 24v UPS Review | Inbuilt Stabilizer
• UTL 24v UPS Review | I...
Solar Energy QnA EP18 About STC vs Real Panel Output, Wire Loss in 6mm, DC setup, Big Inverter Idle
• Solar Energy QnA EP18 ...
How to Increase Inverter Battery Backup | Convert Single Battery Inverter to Double battery [Hindi]
• How to Increase Invert...
[Buying Affiliate Links]
Microtek Inverters-
EB series amzn.to/36mfWW7
Sinewave amzn.to/2UE3Vc0
MSun (Solar) Series amzn.to/3hs65Ej
Buy Energy Meter- (for Checking wattage of Devices)
Meco Energy Meter amzn.to/38wUY9e
Meco Pg08t Power Guard amzn.to/3nalMA4
Meco PG07 PowerGuard amzn.to/32z1ubF
MECO POWERGUARD PG09-1A amzn.to/36i9XRq
Buy High Quality AC/DC True RMS Clamp meters (RECOMMENDED)-
My Meter- (Mastech) amzn.to/342Ogp0
Sigma Instruments 1000A amzn.to/3nagmWA
HTC Instrument CM-2056 Clamp Meters - 1000A Ac Dc amzn.to/3d8afxD
Fluke 362 amzn.to/36rwEo9
Buy UTL Gamma plus-
amzn.to/2ZteCg9
amzn.to/2BWMg5N
amzn.to/2NPuSCE
Buy solar Panels
amzn.to/2VHN85s
amzn.to/2NQukwg
amzn.to/2CW7xwU
amzn.to/2C37sa8
Buy Solar battery
amzn.to/38jPXys
amzn.to/2YRpeWR
Buy Solar DC wire-
amzn.to/2YRKNGT
amzn.to/2Blmbxv
[Links & Credits]
pixabay.com/
[My Social Media]
Join this channel to get access to perks:
/ @zeninnovations
Visit My Other YT Channel Zen Gadgets-
/ @zengadgets
Join Telegram Group!-
• Zen Innovations is now...
Follow my FaceBook Page!
/
Join me on ODYSEE and LBRY !
odysee.com/$/i...
lbry.tv/$/invi...
Follow my Tumblr Blog For Early access to Content-
/ zen-innovations
Background Gameplay Footage provided by Zero copyright Gameplay (ZCG)-
/ @zerocopyrightgameplay
Disclaimer-
Any Experiments, Tricks, Tips, DIYs and Procedures shown in this video shall be tried solely at your own Risk. Zen Innovations, Its owners or Partners will not be responsible for any Kind of Harm, Injury,Death, Broken Equipment, Lost Data, any Other losses etc arising out of application of above video.
Affiliate Links Disclosure & Disclaimer-
This Post or Description might contain Affiliate Links. Which Means that, at No additional cost to you, If you use these links to Buy Products, we earn a small commission. The Generated Revenue Helps to keep this channel running.
Copyright Disclaimer-
Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, commenting, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use.
I just tried enabling Grid charging with my 300AH battey and around 4Amps of current consumed in Float. Thanks to Grid charging disable option in Gamma.
Excellent video. Your videos inspires us for DYI stuffs. Thanks again
You're welcome
Only channel on youtube that talks about the real cost of using inverter setups available in Indian market. Bahut dino se dhoondne ke baad ja ke sirf ek channel mila hai.
Thanks
Sir, i hav 1kw solar system with luminous nxg1800 model,
My problem is the battery was full and indicator show not charging but inverter consume 50 watt....
Please explain why...
ua-cam.com/video/aJj7359Tto4/v-deo.html
ua-cam.com/video/LMEtuLoFhFw/v-deo.html
सर।गामा प्लस ईन्वर्टर पर ट्यूबलर बैटरी 150ah c10 है ईसे smf मोड पर रख सकते हैं क्या?या ईसे ट्यूबलर मोड पर ही रखना जरूरी हैं
Tub mode is recommended.
Meri purani battery hai jo sirf 10-15 min backup deti hai. Mera electric bill bhot high aane laga
Kya purani battery se bill double triple ho sakta hai?
Possible. Get a new battery.
बहुत अच्छी जानकारी।
Keep it up.Thanks.
Thanks.
My battery is 200ah and before that I used to charge it via 4amp current and recently I increased it to 12amp due to so much time to get fully charged but does it gonna increase my electricity bill than before?
4amp was before now 12amp batter charging output
Naturally.
900 va investor + 150 ah battery kitna electricity consume karega full charge honekile ?
Can you please explain the difference between Solar PV maximum charging current I max PV 27A and Maximum solar charging Current 120 A.
This is for?
Thank you sir for the information... esliye bijli bill jyada ara hain mera abhi pata chala 😊
Great!
Excellent calculations...isn't it coz inverter itself consumes se power to run itself?
Yes. Idle draw is one thing, but inverter is also wasting way too much power to charge & float the battery. All this ads up over many months.
प्रयोग अच्छा लगा सर आप का इन्वर्टर बैटरी टॉपअप कर रखने में 30 वाट ले रहा है, जो ज्यादा है, मेरा इन्वर्टर तो 18 वाट लेता है 100ah बैटरी पर। वैसे मैं ग्रीड चार्जिंग ऑफ रखने वाला इन्वर्टर अभी अभी लिया हूँ। जब बैटरी 13.5 वोल्ट आ जायेगी तो ग्रीड चार्जगिंग ऑफ कर दूंगा ताकि लोड ग्रीड से चले मगर बैटरी चार्ज मत करे जब बैटरी कुछ कंज्यूम हो जाएगी तब चार्जगिंग on कर दूंगा। अब ये देखना है कि ग्रीड चार्जिंग off औऱ no load पर इन्वर्टर कितना watt कंज्यूम करता है।
Thanks for commenting.
Superbly explained,thanks a lot sir
Welcome
Sir mere pass purana transistors wala invertor hai... battery full charge honne par cutt of ke baad koi current nhi deta battery ko (no floating current). I always thought ke new digital invertors also do same. One disadvantage of no floating current is if there is a power cut only for 30 seconds after 5 days once full charged, invertor will going to take 2-3hrs to charge again since some current is lost during those 5 days idle. Another disadvantage, if no power cut for many days, battery will not be at its 100%. But major advantage is power saving will be huge. My invertor consumes only 5W once battery is full and output disconnected. Those 5W is due to in these invertor relay is energized and a small circuit.
I think new invertor should provide option to disable or enable this option. Due to this floating current, it is consuming lot of power. I was thinking of upgrading to digital invertor, but this may have convinced me to keep old one. :)
Float is very important to maintain the health of lead acid battery, otherwise gravity will fall. What you are saying is possible in Lithium (LFP) batteries as they can hold the charge for weeks & months without requiring any float current.
However sadly, not many lithium compatible inverters available in Indian market.
@@ZenInnovations Yes maybe incase where there are very less power cuts and battery kept idle for many days. Here as you know there are power outage after every 2-3 days, maybe in those cases it works. Using this invertor for more than 10yrs, this is the second battery.
Yes lithium battery pack would be awesome once it becomes mainstream in India.
Hello sir, i don't what's happening, my inverter constantly taking more than 250 watts even after charging battery to the full. I thought my battery is old that's why. But i replaced my battery to the new but even after that it is taking more than 250 watt after full charging. My inverter model is luminous zelio 1100 single battery. Inverter was also checked by the mechanic. Can you help out advice
Check using a good clamp meter. What's actually happening?
same here happening. i decided to change inverter
Mere pass microtek ka 2300sw 24v model hai with 230ah x2. Idle power consumption on mains kitna hoga? And how do i calculate the load connected to the inverter with clamp meter?
Amps x volts = Watts.
i wish sir if u would done this text with 150Ah which is common battery we would get real idea :( but ur video teach me a lot thank u for this info
Cool
Sir bijli losses se bachne ke liye konsa inverter lagaye.bina solar wala
Solar pcu lagao
Sir mera questions ---Kya battery charging nehi karnese bhi Inverter AC power consume karega ?pl answer.
Yes, It Consumes Idle as shown here-
ua-cam.com/video/xUBhjTIJWgc/v-deo.html
Dear Sir.
How to Disable Grid Charging in Normal inverter which Using with Solar charge controller?
Depends on the inverter. It's not easy on some.
Sir mere pass 600 eb ka microtec ka inverter hai uske sath 165 ah ki battery hai jo 3 saal purani hai ab problum ye hai ki inverter 12 14 ghante baad charging cut karta hai lekin agar light 5 minut ke liye bhi chali jaye to dubara 5 6 ghante charge karta rehta hai inverter ko check kiya to 10.5 volt pe low cut ho jaati hai
Maybe battery is faulty.
बोहोत अच्छा लगा
Thanks.
bro do this type of experiment with utl gamma plus 3kva model please!
Sure.
Sir square wave inverter sine wave se jyada energy leta hai? Charging me aur backup me. Overall efficiency me
Square wave it not effective when it comes to motor load. For resistive load it does not matter.
@@ZenInnovations aur charging full hone ke baad me sine wave hamesha garam rahta hai. Aur square wave thanda rahta hai. To kya sine wave vala jyada energy consume karta hai?
@@anonymous67143 maybe yes.
@@anonymous67143 yes you are very good observor
Can I disconnect my sine wave inverter when nkt in use (after full charge) by using bypass switch or manual disconnecting ? As the sine wave inverter is continuously taking some power as it feels hot when touched, it means it is taking some power continuously, so to reduce this power consumption can we disconnect it , will bypass switch will help ?
Then how do you plan to maintain the batteries?
It's consuming 20-25W to maintain , I face power cuts once in a while like 30-60min in 3-4 days gap, will it be necessary to maintain battery ?
@@Ashutosh_Singh_Chandel yes.
What is the reason the hybrid inverter draw power from Grid rather than from PV panels or batteries eventhough the battery is charged to more than 70% and there is Sun.
Depends on the model. Pls check the settings.
Hi sir, I am using livfast 900va square wave inverter and livfast 12v×210ah(=2520VAH) battery , The charging current from grid is 220v 4.1A 0.4 power factor
sir please tell me the power consumption of inverter to full charge ???
Just watch the video carefully. You can use a good power meter. Links in decription.
0.86 per hour unit
Nice testing & observing Zen ji 👍
Thanks sir.
Excellent video tnxx✌️✌️✌️
Welcome
Nice information zen ji 👍👍👍
Thanks Dip Ji
Waiting for this video.
Coming soon
Sir mera 5kg watt ka samarton ka inverter ha or 3kg ka solar ha or utl ki 3year old 4battry ha .hum din me solar se chalta ha or raat 6/7 baje bijli ko on kerte ha .bil jayda aa raha ha .solar ka koi benefit nahi ho reha. 1.5 hp ki moter ko subh or raat ko chlate ha kyunki paani ki jarurat subh or raat ko hoti ha .to moter solar se nahi chal sakti .kabi kabi din me chla lete ha 1hour to chal jaati ha .700/800watt ka load pure din chalta ha .jithni bijli din me bachti ha .ye sayad us se jayda charge kerne me leta ha kya problem ho sakti ha .kyuki mere ghar me 5 fan 5tube light ak frige 2 tv chalte ha pure din raat or 2 hour subh 2hour raat pani ko moter 1.5hp is hissab se agar 24hour bijli per apna gher chalata hu to 1din ki unit 20 maan lo .lakin din me solar se chalta ha 6/7baje k baad bijli on ker dete ha or 4/5 hour baad bijli off or raat ko 4/5hour baatry se chalta ha .fir bhe mene dekha 1din ki unit 18/20 aa rehi ha .kya problem ha sir.kya 5kg waat ka sollar battery ko charging me unit le reha ha jayda kya
Turn off Grid charging from smarten.
Solution kya he solar ke alawa ??
23Units x Rs 8
How you calculate 8
For Max 0-30 unit slab
1.92 ₹ per unit
So how u multiple 8
I am sorry can you explain
8 is average rate.
Rate depends on your areas & taxes.
Once you cross 500 units per unit cost is higher and avg rate of per unit increases.
Very informative video
Glad you liked it
Sir Gautam solar panel 400 watt monocrystalline Kaisa hota Hai sir please reply
Dear Subscriber, Its nice that you want me to Test & compare various Products. However, I cannot keep buying all the products. Hence what you can do is to tweet these companies to send me a review sample.
Nice and informative video.
Thanks
Wahi 187watt ko cancel kr skte h night times me main ko switch off kr k.
Better invest in solar energy.
thank u sir 👍🙏🤞
Most welcome
UTL GAMA PLUSE 12VOLT INVERTER ME BACK SIDE ME AC RESET SWITCH KA KYA WORK H ... PLEASE HELP ME
It's like a small MCB
Nice information sir ji
Thanks!
Good information.
Thanks
Kam ah ki battery ko float voltage pe maintain krne ke lie kam current chahie isi tarike se inverter ko pata chala ki kitna current dena ha
Interesting observation
wow i got 2 150Ah battery it means easy to maintane i must be using almost 80 to 100 units per month thats why i tried may ways i couldnt find why my bill was so high
Thanks
200Ah ki tall tubular battery
Luminous zolio 1100+ sinewave inverter
Ye standby mode (full charge hone k baad) me kitna power background me consume karta hoga?
Power to daily cut nahi hoti hai
But UPS continue start hi rehta hai
Kuch toh continue consume karta hi hoga(other than charging)
Roughly kitna consumption hoga to maintain full battery
And solution for power saving.
In apartment no provision for solar panels.
I don't have luminous but I Can guess 30 to 50w leta hoga.
@@ZenInnovations for calculation
40 watt ×24= 960 wattage in 24hrs
ie. 0.95 Unit per day in stand by mode
Agar 15 days no power cut
फिर भी 15 यूनिट का बिल ज्यादा आयेगा।
Just for a assurance ki battery charge rahe.
@@inderjeetsingh-yy6fr Yes.
Without battery inverter kaam karega only raw power sey?
Mera connection hey aur battery mainey remove kardiaa us condition mey raw power input sey output dega?
Not recommended.
@@ZenInnovations thanks,mera inverter ki uper 100w ki load hey, mujhey battery connection hatanaa hey, connection remove kardiaa battery wala us condition mey grid power aviaable hey fr mera load inverter ki uper chalataa rahega yaa nhi?
@@Shaktimasti buy hybrid or batteryless inverter...
Is it possible that inverter consumes 1.7 unit approx daily without any power cut?
You could have a bad battery, which is not holding charge.
@@ZenInnovations thanks for your response. That means, its possible.
Square wave inverters doesn't trickle charge after full charging battery
All lead acid batteries need trickle charge. Square wave or sinewave does not matter.
Nice information
Thanks
Thank 🙏 bhadu mama
Sir jab se mene inverter lagaya h bijli bil 4x bad gya hai jabki bijli utni hi use hoti hai jitni pahle hoti thi
Check if battery is good or its being overcharged.
Nice video brother 🙏🙏
Cool
Super Bro
Thanks
This inverter find out through voltage and current potential
Voltage increase.. Amp decrease
Thanks for commenting.
Okay
good
Thanks
Nice video bro
Thanks for the visit
Sir mere purane ghar par 1 inverter tha ab naye ghar me pahle se inverter tha to hamne purane ghar ki battery naye inverter me jod di kisike suggestion par taaki jyda back up mile aur purani battry ka bhi use ho sake....ab mujhe lagta hai ki isaki wajah se bill bahut jyda aa raha h. Par mujhe nahi pata ki ye sach h ya nahi. Pls help 🙏
Pls check battery health using good clamp meter & hydrometer.
maybe battery is faulty or shorted.
@@ZenInnovations thank you for you suggestion sir....lekin kya aap ye bata sakte hai ki kya ye sach hai ki 2 battery jodne se electricity jyda consume hoti hai or jyda light bill aata hai.
Charging ke liye jyada energy lagega. Thoda sa fark padta hai.
@@ZenInnovations thank you once again sir😊
Sir bijli bill bahut aa raha hai rasta bataye
Get solar setup like this ua-cam.com/video/_KDDVLtq3Pk/v-deo.html
😅