in a split phase system (Canada), one approach is to use a X:240vac output transformer with a center tap to give an L1, L2 240v and L1 or L2 to CT, 120vac. Does this cause problems with load balance? Thanks Doug
Hi im still leaning about this stuff. Should the turn ratio not be as follows? 220/14=15.7 so should it not be 16 turns per volt? Primary =224 turns and secondary = 3520? Sorry just learning.
The choke will filter the high frequency voltage before going into the transformer. It reduces the no-load current. I have seen several Chinese inverter boards that use it before. So I tried, it worked fine. aliexpress.com/item/32909770919.html
How did you calculate 14 turns is enough for primary coil? As I can understand, more turns means lower idle current. If you make only 1 turn you will create a short circuit.
@@PhdHung Chokes is not to reduce no-load current. Its main purpose is to reduce sudden inrush current when the transformer is switched ON. The inductive reactant of the transformer is the main resource of impedance in a transformer. The inductive reactant is zero when the transformer is OFF. It comes to the picture when a transformer is ON. Hence when we switch ON the transformer, it takes heavy current at starting (like AC Induction Motors). This current dies once the inductive reactant of the transformer comes into the picture ( as a transformer is ON now). To protect the transformer from damage due to heavy starting current, the choke is connected in series of the transformer. The inductance of the choke is selected in such a way that it offers high impedance to heavy current, but the low path to normal current.
This is nice!But I want to ask, what if you increased the number of turns of both the primary and secondary windings in the same ratio?For instance, instead of the '220 turns :14turns', you decided to make use of "440turns : 28turns"
What should be the secondary voltage of the transformer for 48v battery? As far as I understand 7v is for 12v, 14v is for 24v so is it 28v for 48v system? :)
inverters using iron transformers will work for a long time, have a large power, can overload without burning. However, the performance is lower than that of the inverter using a pulse transformer, it is also heavier and more expensive.
Is it normal for the inductor to warm up a bit and warm up the transformer with a load of 100W? Can you work without the inductor? Can I make an inductor with a metal toroid? Thank you
Mujhe 2 se 3kw load chlana hai. Main ek wind turbine bna rha hun. 2ya 3 kw ke liye 12v chahiye ya 24v chahiye? battery or bina battery ke liye kon sa controller lagega???????? Please reply
@@PhdHung I like and Appreciate your work u r doing very well keep it up. A transformer having bobin size of 2×3 coiled with 10 swg and 19 swg for chagring and inverting how much output it will give kindly guide me
When you finished winding your transformer you should test& show the output voltage like the one you showed in, 1000w. Secondly can I know why don't you use the same original wire insulation instead your using pVC sleeve what is the reason please let me know.
From your calculations I don't understand how you get the secondary current to be 160A and the wire size to be 16mm^2 kindly explain to me your secondary voltage is 14v since the because the 24v is divided into 2 to give 12v-14v
Where did you get your transformer iron? If I understand correctly, judging by the dimensions, this transformer was used in an uninterruptible power supply before rewinding, right?
can I just use 20A transformer instead 100A for 2000W? ...because 20A is already available in the market, also can I use 10A in pair?, becuse buying 2 x 10A is cheaper than a single 20A
Hi.. I want to make 3000watts 24v 220va.. Can you help me ..? Plss send me a requirements to do so. What gauge af wire for secondary and primary..how many turns and what size oaf core do I need to use. Thank you..looking forward for your help. ?
@@PhdHung my brother honestly I must have watch your videos at least 200 times. May I most humble ask another question? After you do the you do the first sets of turns do you put the wax paper in between each sets of turn until you reach the set turns are you can do turns on top of turns until you reach your set turns? I am doing for 110v @ 146 turns?
@@PhdHung my brother honestly I must have watch your videos at least 200 times. May I most humble ask another question? After you do the you do the first sets of turns do you put the wax paper in between each sets of turn until you reach the set turns are you can do turns on top of turns until you reach your set turns? I am doing for 110v @ 146 turns?
Hi; Is the transformer operated with a full bridge inverter? because on the secondary side the center tap of the coil is missing. many greetings from Germany AND MUCH SUCCESS.
Vì người ta lịch sự hỏi , sau khi mình trả lời thì luôn comment lại "thanks" "thanks sir" "God bless you" . Còn mấy tay VN thì hầu hết là luôn "bố đời" , hỏi cộc lốc. Chưa kể lấy file về làm bán rồi nhận luôn là tự làm nữa chứ. Cái gì nó cũng có nhân quả của nó thôi.
@@PhdHung ừ...mấy tay đó là vậy mà...anh không trách chi cả.....vì anh chỉ là thợ may...không phải nghề của em...nhưng thích xem kỉ thuật điện...he he heb nếu em có tâm ...hãy giúp đồng bào dân tộc và người vùng sâu vùng xa nha ,chứ dân thành thị thì chỉ buôn bán thôi ....kakakaka hôm nào chắc nhờ em tư vấn .....về điện
Do you want to use it at 12V or 24V? If you use at 12V, you need a single 7V transformer to 220V. If you use a 24V battery, you need a 14V to 220V transformer. Your 100A transformer is great, but it needs a little fixing on the primary winding.
Hi sir i have 48v 3000w toroidal transformer from my broken inverter,, i want to buy a inverter board 24v 3000w,, can i use the 48v 3000w for that 24v 3000w inverter board? Or do i need to re rewind the primary? Thank you,,
2000watts inverter used 24volts battery power it may need up to 2battery connected in series to get 24volts it just used to much power to run it it cost to much to expensive to build a 24volts DC power battery charger to charged a 24volt to run every days used without a solar it will drive your electric bills when up the roof
sorry want to ask again, for how many primary wire need kg? and the size is how many mm and the secondary size is how many mm? please give the unit mm,
Homemade 102 // i think its used to make the current stable (current filter) work as the capacitor filter but with current not voltage as i read on the internet thank you very for this amazing video
You’re a genius my freind!! The big power company must not like you 😂 ... keep up the good work.
Google language translator please? This way they will have more people who can understand each language of their country. Thank you
chắc nhờ bạn tự vấn làm cái inverter này quá....2000w còn 1500w để chạy cả ngày là thích lắm....he he he
I had made that u make for me 150w LED tester. That is very use full for me to repair led TV. Thanx again bro. ❤️
congratulation.
in a split phase system (Canada), one approach is to use a X:240vac output transformer with a center tap to give an L1, L2 240v and L1 or L2 to CT, 120vac. Does this cause problems with load balance? Thanks
Doug
I'll wait for the testing
Next video: D
Please can the addition of inductor in a modified Sine Wave Inverter also help it to become pure Sine Wave?
Hi im still leaning about this stuff. Should the turn ratio not be as follows? 220/14=15.7 so should it not be 16 turns per volt? Primary =224 turns and secondary = 3520? Sorry just learning.
I really like the way you wind the transformer. The choke was just straight forward. Can we have more information on the choke ?? Thanks
The choke will filter the high frequency voltage before going into the transformer. It reduces the no-load current. I have seen several Chinese inverter boards that use it before. So I tried, it worked fine. aliexpress.com/item/32909770919.html
@@PhdHung Thank you for explaining this to me Homemade 102. Good day too.
No words no explanation?
Excellent work!
Thanks❤😊
Excellent video 👍
thanks bro
You are very excellent
Thanks
Hi, I want to know about the inductor, why using an inductor for a toroidal transformer? and for each capacity how to calculate winding turns?
Exelente es un joby adictivo
Thanks bro
Well i am a beginner in electrical engineering but i did not understand that why you have added a choke???Is it necessary to add a choke???
It filters high frequency signal before entering transformer. It reduces the no-load current.
@@PhdHung Thanks for the reply
Hay, nếu có điều kiện chia sẻ cách quấn biến áp xuyến công suất lớn luôn bạn nhé. Cảm ơn đã chia sẻ!
ok, xuyến dễ quấn mà.
How did you calculate 14 turns is enough for primary coil? As I can understand, more turns means lower idle current. If you make only 1 turn you will create a short circuit.
nice work it should work for you. i like how much you are determined.
Why did you use the 2 core chokes ?...,
What is the benefit of them ?
It reduces the no-load current
@@PhdHung Chokes is not to reduce no-load current. Its main purpose is to reduce sudden inrush current when the transformer is switched ON. The inductive reactant of the transformer is the main resource of impedance in a transformer. The inductive reactant is zero when the transformer is OFF. It comes to the picture when a transformer is ON. Hence when we switch ON the transformer, it takes heavy current at starting (like AC Induction Motors). This current dies once the inductive reactant of the transformer comes into the picture ( as a transformer is ON now). To protect the transformer from damage due to heavy starting current, the choke is connected in series of the transformer. The inductance of the choke is selected in such a way that it offers high impedance to heavy current, but the low path to normal current.
@@jameelsheik If the transformer does not have an inductor in series, the power stage may be affected ... are the mosfets burned?
We didn't see the test. Voltmeter. We just didn't make sure it all worked out in the end. Thanks for the persuasiveness.
here ua-cam.com/video/L5_UqRkCI7M/v-deo.html
Muy bueno señor, ¿y para 120v que toca modificar?
Great work bro. Keep it up. We'll done
@@PhdHung what is mean by
sorry I want to ask, how many uh inductor inverter egs002 so that the standby current is small?
Why do you choose TPV to be 1 for and also why do you choose 1.5mm^2 for secondry and 16mm^2 for primary
Nice inverter really
I am waiting for real testing video
This is nice!But I want to ask, what if you increased the number of turns of both the primary and secondary windings in the same ratio?For instance, instead of the '220 turns :14turns', you decided to make use of "440turns : 28turns"
Not enough space. However, if using 440 and 24 turns. No-load current will decrease. Fine, no problem.
@@PhdHung this may make the transformer more efficient.
Why?
What should be the secondary voltage of the transformer for 48v battery? As far as I understand 7v is for 12v, 14v is for 24v so is it 28v for 48v system? :)
Very good inverter taransfarmer
is it different? copper 1.5mm made 16mm with 0.3 copper made 16mm? do we need to peel the copper skin first?
I have square transformer from welding machine can i use it for puresinewave inverter if i rewinded new coils?
Is it always better to have a low frequency transformer than a high frequency transformer? For inverter
inverters using iron transformers will work for a long time, have a large power, can overload without burning. However, the performance is lower than that of the inverter using a pulse transformer, it is also heavier and more expensive.
Hello and thank you very much. If possible, how easy is it for a simple trainer to make a 12V to 220V 100 Amp transformer?
ok, wait me
Is it normal for the inductor to warm up a bit and warm up the transformer with a load of 100W?
Can you work without the inductor? Can I make an inductor with a metal toroid?
Thank you
No, the coil is very cool, you may not need it, but your transformer must be of good quality
How many primary turns
And does the yellow and blue wires are all twisted?
Primary transformer 12 turns ~ 14Volt
Mujhe 2 se 3kw load chlana hai.
Main ek wind turbine bna rha hun.
2ya 3 kw ke liye 12v chahiye ya 24v chahiye?
battery or bina battery ke liye kon sa controller lagega????????
Please reply
Very Good Brother, thanks for such a detailed and informative video.
How many turns is the choke inductor and wire size to give you 120uH
It was a difficult approach, what will happnen to thick wire in case of increase in temp.
The wire has a 16mm cross section, according to the datasheet, it can load 160A. but I only use up to 90A. So it is very safe.
@@PhdHung I like and Appreciate your work u r doing very well keep it up. A transformer having bobin size of 2×3 coiled with 10 swg and 19 swg for chagring and inverting how much output it will give kindly guide me
When you finished winding your transformer you should test& show the output voltage like the one you showed in, 1000w. Secondly can I know why don't you use the same original wire insulation instead your using pVC sleeve what is the reason please let me know.
I have a 48v/200Ah battery the transformer is for pure sine wave inverter how do I calculate the secondary wire size.
Kindly do a full tutorial video showing all your transformer design calculations and the inductor design calculations
From your calculations I don't understand how you get the secondary current to be 160A and the wire size to be 16mm^2 kindly explain to me your secondary voltage is 14v since the because the 24v is divided into 2 to give 12v-14v
Hi friend thank you for your video what is it mean primary 14~14 turns is it full wave
Where did you get your transformer iron? If I understand correctly, judging by the dimensions, this transformer was used in an uninterruptible power supply before rewinding, right?
Can send the size of the iron plate of the transformer
EI 75 x 62.5
EI 84x70
Please appreciate your help
Thanks
Firmino
Hello sir, if I buy EGSOO2 it needs to reprogram or install it directly to the inverter?
install it directly. EGS002 is ready to work
Ok thanks....
How long primer wire you used broo?
can I just use 20A transformer instead 100A for 2000W? ...because 20A is already available in the market,
also can I use 10A in pair?, becuse buying 2 x 10A is cheaper than a single 20A
If you use 20A transformer, you will have max 20A x 12V = 240W. or 20A x 24V = 480W
@@PhdHung And 20A x 48V = 960W, if you use 48v and 50A you get 2000W half the weight of the transformer, better performance.
GREAT! ⚡
Hi.. I want to make 3000watts 24v 220va.. Can you help me ..? Plss send me a requirements to do so. What gauge af wire for secondary and primary..how many turns and what size oaf core do I need to use. Thank you..looking forward for your help. ?
ok. Post your request on Facebook. Everyone will calculate for you.
Please can you educate me as I do not understand why you did 14 turns on the 24v side and not 24 turns is it because you used two wires combine?
EGS002 requires the voltage of transformer is 7V with 12V battery system, I use 24V battery, so I need to build transformer 14V to 220V.
@@PhdHung my brother honestly I must have watch your videos at least 200 times. May I most humble ask another question? After you do the you do the first sets of turns do you put the wax paper in between each sets of turn until you reach the set turns are you can do turns on top of turns until you reach your set turns? I am doing for 110v @ 146 turns?
@@PhdHung my brother honestly I must have watch your videos at least 200 times. May I most humble ask another question? After you do the you do the first sets of turns do you put the wax paper in between each sets of turn until you reach the set turns are you can do turns on top of turns until you reach your set turns? I am doing for 110v @ 146 turns?
wow, good job!
Nice video
Please bro what formula do you used in calculate the number of inductor turns which is 14turns thanks.
Congratulations on the channel !! I would like you to make a video about your rewinder, the spinner and motorcycle scooter?
Yes, it is a good idea, I will do it
Can I use 6mm two wires I not have a 8 mm two wires please reply
yes, ok bro
what is THE USE OF 2CORE CHOKES 55MM 14 TURNS WIRE?
Hi sir..
How many truns for 12 0 12 .? Like this transformer. 100A
i need transformer core size, i will calculate it for you.
Can i use ups 12 v transformer for 2000w inverter
no. You need bigger transformer.
How much battery needed for 1500w submersible pump
@@siddhant005 For 500 watt 12v
1.5 kw 36 volt is best
In 12v 2000 watt system primery current 290 amp .
Kaisey handle krogey?
Please what is the length of the 16mm2 wire..
congratulations, what are the core chokes?
13kg,how many copper wire you used?And why 24v inverter system is 14turns?
I use H. Bridge with voltage feedback. It requires 7Volt primary coil / 12V battery system. If using 24V battery system. It needs 14V primary to 220V.
5:25 Doesn't looks like 8mm².
4mm² maybe.
hi super video I can ask you about the wire cross section you thought 1.5mm² or 1.5mm thank you 0:38
,, nice content,,, I recently made a big transformer it draws 60 watt without load,, can we do something about it.???
Add an inductor, like I did
I make a big transformer but it get really hot in seconds can u tell me why is this happening
Jó estét mindenkinek Hogyan számoljam ki a CT-transformatort?
Good day homemade 102. Can I produce same 2000W with core size 5x6x7cm?
probably not. It is a little small
Ok felicitari
hogyan lehet kiszámítani a transzformátorok ct-arányát
Hi;
Is the transformer operated with a full bridge inverter?
because on the secondary side the center tap of the coil is missing.
many greetings from Germany AND MUCH SUCCESS.
Yes, it works with H-bridge, I built H-bridge and SPWM control circuit. If you want, you can review the videos in my video list.
@@PhdHung DANKE.
@@PhdHung nh n
ok . thank you.i need it (transformer detail ) for make with your 2000 w inverter feed with 12 volts
How mach Core size.?
Good
thanks bro
14 turns only ? Isn't that almost just a dead short on the 24V battery ?
So nice vdo
Sir inductor ka use kyu kiya h esme.. Please explain sir
bạn giỏi thật....nhưng chỉ mấy bọn châu phi đi,bạn đâu có nói chuyện và chơi với người VN đâu he he eh
Vì người ta lịch sự hỏi , sau khi mình trả lời thì luôn comment lại "thanks" "thanks sir" "God bless you" . Còn mấy tay VN thì hầu hết là luôn "bố đời" , hỏi cộc lốc. Chưa kể lấy file về làm bán rồi nhận luôn là tự làm nữa chứ. Cái gì nó cũng có nhân quả của nó thôi.
@@PhdHung ừ...mấy tay đó là vậy mà...anh không trách chi cả.....vì anh chỉ là thợ may...không phải nghề của em...nhưng thích xem kỉ thuật điện...he he heb nếu em có tâm ...hãy giúp đồng bào dân tộc và người vùng sâu vùng xa nha ,chứ dân thành thị thì chỉ buôn bán thôi ....kakakaka hôm nào chắc nhờ em tư vấn .....về điện
It is 1100 watts only,because your wire thickness is1.5 mm, this diameter wire capacity maximum 5 amp. so 5amp.*220 v equal to1100 watts .
thank
Bro plz make transformer less inverter for solar panels direct 310 vdc to 220 ac .
That's a good idea, I'll design it
@@PhdHung yes we will wait. Because it is better for future.
What is the use of ferrite ring chok in the transformer
reduce the no-load current.
@@PhdHung it reduces the inrush current during switching.
Jen nevím jak stoho dostat 100A odhadem podle velikosti bych tipoval tak 20A
Nice! What is the puropse of the toroidal inductor?
It reduces the no-load current.
2:53 which is the music ?
also my bro i have one question . i want make your 2000 w inverter for 24 Hours work with 1800w load .is it suitable? (12 to 220 2000 w inverter)
How much is the Henry value of toroidal cores ?
~ 47uH
hi Homemade 102.... i have trafo 12-0-12/220V 100A, can i use it with this project? thanks
Do you want to use it at 12V or 24V? If you use at 12V, you need a single 7V transformer to 220V. If you use a 24V battery, you need a 14V to 220V transformer. Your 100A transformer is great, but it needs a little fixing on the primary winding.
@@PhdHung i want to use it at 24V... so i have to rewind it both primary and secondary? thanks
No, just edit the primary coil.
@@PhdHung thanks and more power....
Hi sir i have 48v 3000w toroidal transformer from my broken inverter,, i want to buy a inverter board 24v 3000w,, can i use the 48v 3000w for that 24v 3000w inverter board? Or do i need to re rewind the primary? Thank you,,
Yes u will have to rewind
2000watts inverter used 24volts battery power it may need up to 2battery connected in series to get 24volts it just used to much power to run it it cost to much to expensive to build a 24volts DC power battery charger to charged a 24volt to run every days used without a solar it will drive your electric bills when up the roof
Can i use a microwave transformer for an inverter please?
ok, but the performance will be lower
@@PhdHung why the performance will be lower? I need to use the microwave transformer to make a power full inverter like yours
ทำเครื่องชอตปลาสบายมากๆ
for the secondary wire, what is the diameter of the wire?
u use 1.5mm2
sorry want to ask again, for how many primary wire need kg? and the size is how many mm and the secondary size is how many mm? please give the unit mm,
@@PhdHung Ans. in S.W.G.
Nice and neat work, what Amperage on secondary side (AC)?
Como permitir que um inversor consiga pôr a funcionar um congelador?
OE lá amigo , você não mostrou o transformador funcionando. É muito importante para quem esta assistindo o vídeo.
Hello friend, very good, how to eliminate the electromotive force of the transformer? Thank you
Why do you use those chokes
It reduces the no-load current
Homemade 102 // i think its used to make the current stable (current filter) work as the capacitor filter but with current not voltage as i read on the internet thank you very for this amazing video
I don`t undestand , for what is the donut ???? yes yes the cable yellow in de the circle?? is the other transformers??? greates from Spain friend.
It is an inductor, it will filter high frequency. Reduce the no-load current.