  • @radiocanaltv4872
    @radiocanaltv4872 Рік тому +2

    Google language translator please? This way they will have more people who can understand each language of their country. Thank you

  • @coucouj2781
    @coucouj2781 4 роки тому +4

    You’re a genius my freind!! The big power company must not like you 😂 ... keep up the good work.

  • @KinhKha-lm2zl
    @KinhKha-lm2zl 5 років тому +1

    chắc nhờ bạn tự vấn làm cái inverter này quá....2000w còn 1500w để chạy cả ngày là thích lắm....he he he

  • @victoryfirst2878
    @victoryfirst2878 4 роки тому +3

    I really like the way you wind the transformer. The choke was just straight forward. Can we have more information on the choke ?? Thanks

    • @PhdHung
      @PhdHung  4 роки тому

      The choke will filter the high frequency voltage before going into the transformer. It reduces the no-load current. I have seen several Chinese inverter boards that use it before. So I tried, it worked fine. aliexpress.com/item/32909770919.html

    • @victoryfirst2878
      @victoryfirst2878 4 роки тому +1

      @@PhdHung Thank you for explaining this to me Homemade 102. Good day too.

  • @prasannajayasanka4895
    @prasannajayasanka4895 5 років тому +1

    I had made that u make for me 150w LED tester. That is very use full for me to repair led TV. Thanx again bro. ❤️

    • @PhdHung
      @PhdHung  5 років тому

      congratulation.

  • @en2oh
    @en2oh 3 роки тому +2

    in a split phase system (Canada), one approach is to use a X:240vac output transformer with a center tap to give an L1, L2 240v and L1 or L2 to CT, 120vac. Does this cause problems with load balance? Thanks
    Doug

  • @MansHobbsInterests
    @MansHobbsInterests 9 днів тому

    Hi im still leaning about this stuff. Should the turn ratio not be as follows? 220/14=15.7 so should it not be 16 turns per volt? Primary =224 turns and secondary = 3520? Sorry just learning.

  • @jboy4real
    @jboy4real Рік тому

    Kindly do a full tutorial video showing all your transformer design calculations and the inductor design calculations

  • @mayoortechinnovations
    @mayoortechinnovations 4 роки тому +3

    Please can the addition of inductor in a modified Sine Wave Inverter also help it to become pure Sine Wave?

  • @warrior4serbia
    @warrior4serbia 4 роки тому +1

    We didn't see the test. Voltmeter. We just didn't make sure it all worked out in the end. Thanks for the persuasiveness.

    • @PhdHung
      @PhdHung  4 роки тому

      here ua-cam.com/video/L5_UqRkCI7M/v-deo.html

  • @FaranAhmad-it2xt
    @FaranAhmad-it2xt 4 роки тому +2

    Well i am a beginner in electrical engineering but i did not understand that why you have added a choke???Is it necessary to add a choke???

    • @PhdHung
      @PhdHung  4 роки тому +1

      It filters high frequency signal before entering transformer. It reduces the no-load current.

    • @FaranAhmad-it2xt
      @FaranAhmad-it2xt 4 роки тому +1

      @@PhdHung Thanks for the reply

  • @deanetim979
    @deanetim979 4 роки тому +5

    This is nice!But I want to ask, what if you increased the number of turns of both the primary and secondary windings in the same ratio?For instance, instead of the '220 turns :14turns', you decided to make use of "440turns : 28turns"

    • @PhdHung
      @PhdHung  4 роки тому +3

      Not enough space. However, if using 440 and 24 turns. No-load current will decrease. Fine, no problem.

    • @sandasturner9529
      @sandasturner9529 2 роки тому

      @@PhdHung this may make the transformer more efficient.

    • @harrytopia282
      @harrytopia282 2 роки тому

      Why?

  • @anthonyvaz1976
    @anthonyvaz1976 3 роки тому

    When you finished winding your transformer you should test& show the output voltage like the one you showed in, 1000w. Secondly can I know why don't you use the same original wire insulation instead your using pVC sleeve what is the reason please let me know.

  • @jboy4real
    @jboy4real Рік тому

    From your calculations I don't understand how you get the secondary current to be 160A and the wire size to be 16mm^2 kindly explain to me your secondary voltage is 14v since the because the 24v is divided into 2 to give 12v-14v

  • @antoniof0nty
    @antoniof0nty 5 років тому +3

    Excellent work!

  • @electronic7979
    @electronic7979 5 років тому +2

    Excellent video 👍

    • @PhdHung
      @PhdHung  5 років тому +1

      thanks bro

  • @filipcipagauta2799
    @filipcipagauta2799 2 роки тому +1

    Muy bueno señor, ¿y para 120v que toca modificar?

  • @ramkumarnanu1171
    @ramkumarnanu1171 3 роки тому +1

    Hi, I want to know about the inductor, why using an inductor for a toroidal transformer? and for each capacity how to calculate winding turns?

  • @fury4076
    @fury4076 5 років тому +2

    I'll wait for the testing

    • @PhdHung
      @PhdHung  5 років тому +2

      Next video: D

  • @williancarreno916
    @williancarreno916 5 років тому +1

    Is it normal for the inductor to warm up a bit and warm up the transformer with a load of 100W?
    Can you work without the inductor? Can I make an inductor with a metal toroid?
    Thank you

    • @PhdHung
      @PhdHung  5 років тому

      No, the coil is very cool, you may not need it, but your transformer must be of good quality

  • @jboy4real
    @jboy4real Рік тому

    Why do you choose TPV to be 1 for and also why do you choose 1.5mm^2 for secondry and 16mm^2 for primary

  • @jboy4real
    @jboy4real Рік тому

    I have a 48v/200Ah battery the transformer is for pure sine wave inverter how do I calculate the secondary wire size.

  • @AhmedAli-pu3le
    @AhmedAli-pu3le 4 роки тому +1

    You are very excellent

  • @watirinwahyuwidodo6500
    @watirinwahyuwidodo6500 4 роки тому +1

    Is it always better to have a low frequency transformer than a high frequency transformer? For inverter

    • @PhdHung
      @PhdHung  4 роки тому

      inverters using iron transformers will work for a long time, have a large power, can overload without burning. However, the performance is lower than that of the inverter using a pulse transformer, it is also heavier and more expensive.

  • @lecaonguyen79
    @lecaonguyen79 5 років тому +1

    Hay, nếu có điều kiện chia sẻ cách quấn biến áp xuyến công suất lớn luôn bạn nhé. Cảm ơn đã chia sẻ!

    • @PhdHung
      @PhdHung  5 років тому +1

      ok, xuyến dễ quấn mà.

  • @manojdayal25
    @manojdayal25 4 роки тому

    Mujhe 2 se 3kw load chlana hai.
    Main ek wind turbine bna rha hun.
    2ya 3 kw ke liye 12v chahiye ya 24v chahiye?
    battery or bina battery ke liye kon sa controller lagega????????
    Please reply

  • @arijeetraaay
    @arijeetraaay 4 роки тому +1

    ,, nice content,,, I recently made a big transformer it draws 60 watt without load,, can we do something about it.???

    • @PhdHung
      @PhdHung  4 роки тому +2

      Add an inductor, like I did

  • @morojudas1866
    @morojudas1866 4 роки тому +1

    How many primary turns
    And does the yellow and blue wires are all twisted?

    • @PhdHung
      @PhdHung  4 роки тому +1

      Primary transformer 12 turns ~ 14Volt

  • @shahramfo2684
    @shahramfo2684 4 роки тому +1

    Hello and thank you very much. If possible, how easy is it for a simple trainer to make a 12V to 220V 100 Amp transformer?

  • @jboy4real
    @jboy4real Рік тому

    I like your video but you need to explain in detail using English and also try to reply to your subscriber

  • @vladimirmiletiev
    @vladimirmiletiev 2 роки тому

    What should be the secondary voltage of the transformer for 48v battery? As far as I understand 7v is for 12v, 14v is for 24v so is it 28v for 48v system? :)

  • @BL-rb7jm
    @BL-rb7jm 3 роки тому

    No words no explanation?

  • @alextrezvy6889
    @alextrezvy6889 4 роки тому +3

    How did you calculate 14 turns is enough for primary coil? As I can understand, more turns means lower idle current. If you make only 1 turn you will create a short circuit.

  • @firminopereira7254
    @firminopereira7254 3 роки тому +1

    Can send the size of the iron plate of the transformer
    EI 75 x 62.5
    EI 84x70
    Please appreciate your help
    Thanks
    Firmino

  • @dumidujayakodi1002
    @dumidujayakodi1002 3 роки тому

    Hi friend thank you for your video what is it mean primary 14~14 turns is it full wave

  • @electronresonator8882
    @electronresonator8882 5 років тому +1

    can I just use 20A transformer instead 100A for 2000W? ...because 20A is already available in the market,
    also can I use 10A in pair?, becuse buying 2 x 10A is cheaper than a single 20A

    • @PhdHung
      @PhdHung  5 років тому +1

      If you use 20A transformer, you will have max 20A x 12V = 240W. or 20A x 24V = 480W

    • @neonlight816
      @neonlight816 5 років тому

      @@PhdHung And 20A x 48V = 960W, if you use 48v and 50A you get 2000W half the weight of the transformer, better performance.

  • @lalitsokhal3278
    @lalitsokhal3278 2 роки тому

    Sir inductor ka use kyu kiya h esme.. Please explain sir

  • @waqar_ahmad_jan
    @waqar_ahmad_jan 5 років тому +1

    It was a difficult approach, what will happnen to thick wire in case of increase in temp.

    • @PhdHung
      @PhdHung  5 років тому +1

      The wire has a 16mm cross section, according to the datasheet, it can load 160A. but I only use up to 90A. So it is very safe.

    • @waqar_ahmad_jan
      @waqar_ahmad_jan 5 років тому

      @@PhdHung I like and Appreciate your work u r doing very well keep it up. A transformer having bobin size of 2×3 coiled with 10 swg and 19 swg for chagring and inverting how much output it will give kindly guide me

  • @tegarwirawan9971
    @tegarwirawan9971 2 роки тому

    sorry I want to ask, how many uh inductor inverter egs002 so that the standby current is small?

  • @elmultimediaschoolofartscu3924
    @elmultimediaschoolofartscu3924 Місяць тому +1

    Thanks❤😊

  • @ranker246
    @ranker246 3 роки тому +1

    Can I use 6mm two wires I not have a 8 mm two wires please reply

  • @lanatiarnitovic290
    @lanatiarnitovic290 4 роки тому

    is it different? copper 1.5mm made 16mm with 0.3 copper made 16mm? do we need to peel the copper skin first?

  • @berman9668
    @berman9668 4 роки тому +1

    I don`t undestand , for what is the donut ???? yes yes the cable yellow in de the circle?? is the other transformers??? greates from Spain friend.

    • @PhdHung
      @PhdHung  4 роки тому

      It is an inductor, it will filter high frequency. Reduce the no-load current.

  • @jboy4real
    @jboy4real Рік тому

    How many turns is the choke inductor and wire size to give you 120uH

  • @modicoejuakali9421
    @modicoejuakali9421 5 років тому +1

    nice work it should work for you. i like how much you are determined.

  • @narsingraokumbala6048
    @narsingraokumbala6048 2 роки тому

    It is 1100 watts only,because your wire thickness is1.5 mm, this diameter wire capacity maximum 5 amp. so 5amp.*220 v equal to1100 watts .

  • @sjaycunanan4825
    @sjaycunanan4825 4 роки тому +1

    Hi.. I want to make 3000watts 24v 220va.. Can you help me ..? Plss send me a requirements to do so. What gauge af wire for secondary and primary..how many turns and what size oaf core do I need to use. Thank you..looking forward for your help. ?

    • @PhdHung
      @PhdHung  4 роки тому

      ok. Post your request on Facebook. Everyone will calculate for you.

  • @prasannajayasanka4895
    @prasannajayasanka4895 5 років тому +2

    Great work bro. Keep it up. We'll done

  • @Dc_tech386
    @Dc_tech386 4 роки тому

    I make a big transformer but it get really hot in seconds can u tell me why is this happening

  • @JonathanVaucher
    @JonathanVaucher 4 роки тому

    14 turns only ? Isn't that almost just a dead short on the 24V battery ?

  • @smoke_stackz3168
    @smoke_stackz3168 3 роки тому

    I have square transformer from welding machine can i use it for puresinewave inverter if i rewinded new coils?

  • @howardescoffery4950
    @howardescoffery4950 5 років тому +1

    Please can you educate me as I do not understand why you did 14 turns on the 24v side and not 24 turns is it because you used two wires combine?

    • @PhdHung
      @PhdHung  5 років тому

      EGS002 requires the voltage of transformer is 7V with 12V battery system, I use 24V battery, so I need to build transformer 14V to 220V.

    • @howardescoffery4950
      @howardescoffery4950 4 роки тому

      @@PhdHung my brother honestly I must have watch your videos at least 200 times. May I most humble ask another question? After you do the you do the first sets of turns do you put the wax paper in between each sets of turn until you reach the set turns are you can do turns on top of turns until you reach your set turns? I am doing for 110v @ 146 turns?

    • @howardescoffery4950
      @howardescoffery4950 4 роки тому

      @@PhdHung my brother honestly I must have watch your videos at least 200 times. May I most humble ask another question? After you do the you do the first sets of turns do you put the wax paper in between each sets of turn until you reach the set turns are you can do turns on top of turns until you reach your set turns? I am doing for 110v @ 146 turns?

  • @alcidesacevedo6967
    @alcidesacevedo6967 4 роки тому +1

    Hola buen día,excelente video,q area tiene el núcleo? gracias desde colombia

  • @MohitSK
    @MohitSK 5 років тому +5

    Very Good Brother, thanks for such a detailed and informative video.

  • @AllRounder-ym5cs
    @AllRounder-ym5cs 5 років тому +3

    Bro plz make transformer less inverter for solar panels direct 310 vdc to 220 ac .

    • @PhdHung
      @PhdHung  5 років тому +2

      That's a good idea, I'll design it

    • @AllRounder-ym5cs
      @AllRounder-ym5cs 5 років тому +1

      @@PhdHung yes we will wait. Because it is better for future.

  • @ahmedamin1893
    @ahmedamin1893 5 років тому +6

    Why did you use the 2 core chokes ?...,
    What is the benefit of them ?

    • @PhdHung
      @PhdHung  5 років тому +5

      It reduces the no-load current

    • @jameelsheik
      @jameelsheik 3 роки тому

      @@PhdHung Chokes is not to reduce no-load current. Its main purpose is to reduce sudden inrush current when the transformer is switched ON. The inductive reactant of the transformer is the main resource of impedance in a transformer. The inductive reactant is zero when the transformer is OFF. It comes to the picture when a transformer is ON. Hence when we switch ON the transformer, it takes heavy current at starting (like AC Induction Motors). This current dies once the inductive reactant of the transformer comes into the picture ( as a transformer is ON now). To protect the transformer from damage due to heavy starting current, the choke is connected in series of the transformer. The inductance of the choke is selected in such a way that it offers high impedance to heavy current, but the low path to normal current.

    • @kisi482
      @kisi482 3 роки тому

      @@jameelsheik If the transformer does not have an inductor in series, the power stage may be affected ... are the mosfets burned?

  • @mu_bsmer.estoperez6668
    @mu_bsmer.estoperez6668 4 роки тому +1

    Good day homemade 102. Can I produce same 2000W with core size 5x6x7cm?

    • @PhdHung
      @PhdHung  4 роки тому

      probably not. It is a little small

  • @souris771
    @souris771 4 роки тому

    Where did you get your transformer iron? If I understand correctly, judging by the dimensions, this transformer was used in an uninterruptible power supply before rewinding, right?

  • @narenderverma4203
    @narenderverma4203 Рік тому

    So nice vdo

  • @ivancruzluque2795
    @ivancruzluque2795 3 роки тому +1

    Exelente es un joby adictivo

  • @Stevenson15
    @Stevenson15 4 роки тому +1

    Can i use a microwave transformer for an inverter please?

    • @PhdHung
      @PhdHung  4 роки тому +1

      ok, but the performance will be lower

    • @Stevenson15
      @Stevenson15 4 роки тому

      @@PhdHung why the performance will be lower? I need to use the microwave transformer to make a power full inverter like yours

  • @williamabineni8778
    @williamabineni8778 3 роки тому

    wow, good job!

  • @asadnasser4320
    @asadnasser4320 5 років тому +2

    Nice inverter really
    I am waiting for real testing video

  • @KinhKha-lm2zl
    @KinhKha-lm2zl 5 років тому +1

    bạn giỏi thật....nhưng chỉ mấy bọn châu phi đi,bạn đâu có nói chuyện và chơi với người VN đâu he he eh

    • @PhdHung
      @PhdHung  5 років тому +2

      Vì người ta lịch sự hỏi , sau khi mình trả lời thì luôn comment lại "thanks" "thanks sir" "God bless you" . Còn mấy tay VN thì hầu hết là luôn "bố đời" , hỏi cộc lốc. Chưa kể lấy file về làm bán rồi nhận luôn là tự làm nữa chứ. Cái gì nó cũng có nhân quả của nó thôi.

    • @KinhKha-lm2zl
      @KinhKha-lm2zl 5 років тому

      @@PhdHung ừ...mấy tay đó là vậy mà...anh không trách chi cả.....vì anh chỉ là thợ may...không phải nghề của em...nhưng thích xem kỉ thuật điện...he he heb nếu em có tâm ...hãy giúp đồng bào dân tộc và người vùng sâu vùng xa nha ,chứ dân thành thị thì chỉ buôn bán thôi ....kakakaka hôm nào chắc nhờ em tư vấn .....về điện

  • @aimerfiyaz8695
    @aimerfiyaz8695 4 роки тому +1

    Hi sir..
    How many truns for 12 0 12 .? Like this transformer. 100A

    • @PhdHung
      @PhdHung  4 роки тому

      i need transformer core size, i will calculate it for you.

  • @arifmuchamad1569
    @arifmuchamad1569 2 роки тому

    How long primer wire you used broo?

  • @alexbarrosbrr197
    @alexbarrosbrr197 5 років тому +3

    Congratulations on the channel !! I would like you to make a video about your rewinder, the spinner and motorcycle scooter?

    • @PhdHung
      @PhdHung  5 років тому +3

      Yes, it is a good idea, I will do it

  • @vladimirhorak5564
    @vladimirhorak5564 Рік тому

    Jen nevím jak stoho dostat 100A odhadem podle velikosti bych tipoval tak 20A

  • @juntech..3440
    @juntech..3440 3 роки тому

    what is THE USE OF 2CORE CHOKES 55MM 14 TURNS WIRE?

  • @abiodunolatunji2403
    @abiodunolatunji2403 4 роки тому

    Please bro what formula do you used in calculate the number of inductor turns which is 14turns thanks.

  • @teslapavel
    @teslapavel 4 роки тому

    hi super video I can ask you about the wire cross section you thought 1.5mm² or 1.5mm thank you 0:38

  • @pumukli401
    @pumukli401 4 роки тому

    Jó estét mindenkinek Hogyan számoljam ki a CT-transformatort?

  • @mr.bigboytv8573
    @mr.bigboytv8573 4 роки тому

    Hi sir i have 48v 3000w toroidal transformer from my broken inverter,, i want to buy a inverter board 24v 3000w,, can i use the 48v 3000w for that 24v 3000w inverter board? Or do i need to re rewind the primary? Thank you,,

  • @fury4076
    @fury4076 5 років тому +1

    GREAT! ⚡

  • @carlbrown5150
    @carlbrown5150 2 роки тому

    Isn't the primary the first winding? This seems Bassakwards.!!

  • @M_jawad_Rezaiy
    @M_jawad_Rezaiy 5 років тому +1

    Very good inverter taransfarmer

  • @AhmedAli-pu3le
    @AhmedAli-pu3le 4 роки тому +1

    Why the video clip? Show the full explanation to know how you are right

    • @AhmedAli-pu3le
      @AhmedAli-pu3le 4 роки тому +1

      I am waiting for your response and thank you for your great efforts

    • @PhdHung
      @PhdHung  4 роки тому +2

      ua-cam.com/video/L5_UqRkCI7M/v-deo.html
      ua-cam.com/video/6oMmSDj821o/v-deo.html

  • @petercrane8216
    @petercrane8216 4 роки тому

    Please what is the length of the 16mm2 wire..

  • @ARM_TECH
    @ARM_TECH 4 роки тому

    lõi và fe mua đâu vậy ad, để mua về quấn thử

  • @manvendrasinghchandel9883
    @manvendrasinghchandel9883 3 роки тому

    Please make video on 12 volt high amphere transformer

  • @elmarino3339
    @elmarino3339 4 роки тому +2

    Hello sir, if I buy EGSOO2 it needs to reprogram or install it directly to the inverter?

    • @PhdHung
      @PhdHung  4 роки тому +1

      install it directly. EGS002 is ready to work

    • @elmarino3339
      @elmarino3339 4 роки тому

      Ok thanks....

  • @MrTiger0208
    @MrTiger0208 4 роки тому +1

    Cho mình hỏi cuộn sơ cấp tốn mấy kg dây đồng 1.5 vậy? Thanks

    • @PhdHung
      @PhdHung  4 роки тому

      tầm ký rưỡi

    • @MrTiger0208
      @MrTiger0208 4 роки тому +1

      @@PhdHung Thanks bạn, mình định tự làm 1 ba giống bạn, không biết fe mua 12kg đủ kg nhỉ?

    • @PhdHung
      @PhdHung  4 роки тому +1

      vậy ok r

    • @MrTiger0208
      @MrTiger0208 4 роки тому

      @@PhdHung Thanks bạn, hy vọng chạy được

  • @shahramfo2684
    @shahramfo2684 4 роки тому

    also my bro i have one question . i want make your 2000 w inverter for 24 Hours work with 1800w load .is it suitable? (12 to 220 2000 w inverter)

  • @canenero7559
    @canenero7559 3 роки тому

    congratulations, what are the core chokes?

  • @ajitkumar1579
    @ajitkumar1579 2 роки тому

    When i calculated using 24 to 220v and core dimensions taken from your example, i get roughly same turns (18/160), but the primary wire dia is 7mm and secondary 2mm, these wire diameters are unrealistic !!!!
    For 2000 watt, max secondary current will be roughly 10Amps and primary current will be 100a, the wires you used (1.5mm) cannot handle these current i guess

  • @forgamejust848
    @forgamejust848 5 років тому +6

    13kg,how many copper wire you used?And why 24v inverter system is 14turns?

    • @PhdHung
      @PhdHung  5 років тому +4

      I use H. Bridge with voltage feedback. It requires 7Volt primary coil / 12V battery system. If using 24V battery system. It needs 14V primary to 220V.

  • @ajcbopretor6015
    @ajcbopretor6015 4 роки тому

    2hp ka motar pump chal jayega

  • @abiodunolatunji2403
    @abiodunolatunji2403 5 років тому +1

    Nice and neat work, what Amperage on secondary side (AC)?

    • @harrisonmagrine4396
      @harrisonmagrine4396 5 років тому

      Como permitir que um inversor consiga pôr a funcionar um congelador?

  • @wechselrichterschaltungen
    @wechselrichterschaltungen 5 років тому +6

    Hi;
    Is the transformer operated with a full bridge inverter?
    because on the secondary side the center tap of the coil is missing.
    many greetings from Germany AND MUCH SUCCESS.

    • @PhdHung
      @PhdHung  5 років тому +3

      Yes, it works with H-bridge, I built H-bridge and SPWM control circuit. If you want, you can review the videos in my video list.

    • @wechselrichterschaltungen
      @wechselrichterschaltungen 5 років тому

      @@PhdHung DANKE.

    • @kpbsharma1551
      @kpbsharma1551 5 років тому

      @@PhdHung nh n

  • @siddhant005
    @siddhant005 5 років тому

    That means it is 1200 watt transformer if yes then pls provide instructions for 2000w transformer pls

  • @siddhant005
    @siddhant005 5 років тому +2

    Can i use ups 12 v transformer for 2000w inverter

    • @PhdHung
      @PhdHung  5 років тому

      no. You need bigger transformer.

    • @siddhant005
      @siddhant005 5 років тому

      How much battery needed for 1500w submersible pump

    • @aaravaarav5337
      @aaravaarav5337 4 роки тому

      @@siddhant005 For 500 watt 12v
      1.5 kw 36 volt is best
      In 12v 2000 watt system primery current 290 amp .
      Kaisey handle krogey?

  • @shahramfo2684
    @shahramfo2684 4 роки тому

    ok . thank you.i need it (transformer detail ) for make with your 2000 w inverter feed with 12 volts

  • @szekerespista3758
    @szekerespista3758 5 років тому +2

    Nice! What is the puropse of the toroidal inductor?

    • @PhdHung
      @PhdHung  5 років тому +4

      It reduces the no-load current.

  • @oliveroliveros5289
    @oliveroliveros5289 4 роки тому +1

    hi Homemade 102.... i have trafo 12-0-12/220V 100A, can i use it with this project? thanks

    • @PhdHung
      @PhdHung  4 роки тому

      Do you want to use it at 12V or 24V? If you use at 12V, you need a single 7V transformer to 220V. If you use a 24V battery, you need a 14V to 220V transformer. Your 100A transformer is great, but it needs a little fixing on the primary winding.

    • @oliveroliveros5289
      @oliveroliveros5289 4 роки тому +1

      @@PhdHung i want to use it at 24V... so i have to rewind it both primary and secondary? thanks

    • @PhdHung
      @PhdHung  4 роки тому

      No, just edit the primary coil.

    • @oliveroliveros5289
      @oliveroliveros5289 4 роки тому

      @@PhdHung thanks and more power....

  • @walterriesenberg640
    @walterriesenberg640 5 років тому +2

    Hello friend, very good, how to eliminate the electromotive force of the transformer? Thank you

  • @AllRounder-ym5cs
    @AllRounder-ym5cs 5 років тому +1

    Nice video

  • @suwanjamwan5590
    @suwanjamwan5590 5 років тому +1

    ทำเครื่องชอตปลาสบายมากๆ

  • @vivoY-hc9qs
    @vivoY-hc9qs Рік тому

    Bikin taravo 1500 watt berapa gan,,

  • @حامدنظری-ص4ض
    @حامدنظری-ص4ض 3 роки тому

    Hi.why is 100A=2000 watt. 100A×220v=22000watt.???🤔🤔🤔🤔

  • @prft45699
    @prft45699 4 роки тому

    How can I calculating about transformer? Thanks you so mush. :-)