CMM Probe Calibration

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • Calibration of a probe tip on a manual wrist for a Hexagon Global Classic CMM using PC-DMIS.

КОМЕНТАРІ • 31

  • @benefitizsexy
    @benefitizsexy 7 років тому +5

    Please keep making videos about cmm pc-dmis setups! There perfect! No other videos comes close to the clarity that your videos have! I will personally paypal you money. Im currently learning how to operate/program a cmm machine at my job and all i have is a book from school and the internet to go by. I have setup all kinds of cnc machines and manual machines. Trying to get into a cleaner job

  • @maxprieto5059
    @maxprieto5059 7 років тому +2

    outstanding video. needed to freshen up on my skills and this hit the nail hope more videos follow I liked and subscribed​.

  • @user-td5eq4mk9u
    @user-td5eq4mk9u 9 місяців тому

    please make your movements with the mouse slower and more obvious around the icons so we can see what you are trying to explain. Thanks!

  • @rajpatel2033
    @rajpatel2033 3 роки тому

    come back!! i need more pcdmis tutorials like this

    • @GU_Q_Guy
      @GU_Q_Guy  3 роки тому

      Sorry, I admit I haven't made any in a while. Is there something in particular that you need?

  • @danielm.9431
    @danielm.9431 6 років тому

    Thanks , You explain so well. . I hope to see more videos about cmm.

  • @JayWerx
    @JayWerx Рік тому

    Manually having to move the probe is horrible. Luckily I don’t have to work like that.

  • @mcdoogle274
    @mcdoogle274 7 років тому +2

    With the probe in the B90 positions, you touch the sphere on the wrong position. You have to touch it perpendicular to the probe shaft, not on the top of the sphere. On 13:41 you can clearly see, that one of the first three touch points is a hit with the shaft, which totally screws up your measurement.
    No one does it that way.

    • @rubgamess
      @rubgamess 6 років тому

      i think the same thing....you right..

  • @guillermopatino3928
    @guillermopatino3928 3 роки тому

    refreshing my skill by going back around internet and looking at videos. Thanks for the upload.
    Do you have an FB group?

  • @govindsinghlodhi8286
    @govindsinghlodhi8286 6 років тому +5

    I want to basic information about cmm video

  • @tepeinas11
    @tepeinas11 5 років тому

    What about if we are using a different probe size, let say 6mm ruby ball by 100mm and isn't set on the system yet, how do we add it to the system?

    • @GU_Q_Guy
      @GU_Q_Guy  5 років тому

      have to build a new probe file first. In the probe dialog box type in a new tip name, click on the box at the bottom left, then use the drop down box above it. Find your wrist and select it. Next find the components that connect your stylus. then last find your stylus. The graphic should look just like the one on your CMM. Then calibrate it.

  • @imaginebeyondlimits
    @imaginebeyondlimits 5 років тому

    sir please make video on countura G2 with RDS -CCA styli calibration step by step detailed

    • @cadcamokulu
      @cadcamokulu 5 років тому

      ua-cam.com/video/7sgNzpwEovU/v-deo.html

  • @100american2
    @100american2 5 років тому

    Hi! I’m new to Cmm programming. Quick question, is this calibration refer to a R-Test??

    • @davidflack6430
      @davidflack6430 4 роки тому

      I think the video is calling stylus tip qualification 'calibration'.

  • @raul-nicolaebisceanu7037
    @raul-nicolaebisceanu7037 7 років тому

    Nice! Hope more videos will follow.

    • @gopinath5331
      @gopinath5331 7 років тому +1

      sir please upload a video to insert or programme a probe indexing

  • @williamhuang5329
    @williamhuang5329 2 роки тому

    Hanzhen hamonic drive gear , strain wave reducer,
    robot joint , over 30 years experience

  • @LeadMetrology
    @LeadMetrology Рік тому

    would you want to buy a new cmm?

  • @charlescham2024
    @charlescham2024 7 років тому

    nice vid
    @Leslie Sinnock can you pls show us about importing drawings. i dunno if thats available in PCDMIS 2011. :)

    • @GU_Q_Guy
      @GU_Q_Guy  7 років тому

      Good idea. I'll try to get that up for you soon.

  • @shashikanthugar2844
    @shashikanthugar2844 5 років тому

    Sir,please aplod how to create new stylus rak in cmm Ziess

  • @sagarkaule7964
    @sagarkaule7964 5 років тому

    Plz send me the DMIS software calibration process

  • @richardyip1366
    @richardyip1366 4 роки тому

    thanks

  • @esobey9550
    @esobey9550 5 років тому

    very usefull !!!

  • @davidflack6430
    @davidflack6430 4 роки тому

    Don't you mean stylus system qualification. Have a look at ISO 10360-1.