With the probe in the B90 positions, you touch the sphere on the wrong position. You have to touch it perpendicular to the probe shaft, not on the top of the sphere. On 13:41 you can clearly see, that one of the first three touch points is a hit with the shaft, which totally screws up your measurement. No one does it that way.
have to build a new probe file first. In the probe dialog box type in a new tip name, click on the box at the bottom left, then use the drop down box above it. Find your wrist and select it. Next find the components that connect your stylus. then last find your stylus. The graphic should look just like the one on your CMM. Then calibrate it.
outstanding video. needed to freshen up on my skills and this hit the nail hope more videos follow I liked and subscribed.
come back!! i need more pcdmis tutorials like this
Sorry, I admit I haven't made any in a while. Is there something in particular that you need?
Thanks , You explain so well. . I hope to see more videos about cmm.
refreshing my skill by going back around internet and looking at videos. Thanks for the upload.
Do you have an FB group?
please make your movements with the mouse slower and more obvious around the icons so we can see what you are trying to explain. Thanks!
With the probe in the B90 positions, you touch the sphere on the wrong position. You have to touch it perpendicular to the probe shaft, not on the top of the sphere. On 13:41 you can clearly see, that one of the first three touch points is a hit with the shaft, which totally screws up your measurement.
No one does it that way.
i think the same thing....you right..
Nice! Hope more videos will follow.
sir please upload a video to insert or programme a probe indexing
What about if we are using a different probe size, let say 6mm ruby ball by 100mm and isn't set on the system yet, how do we add it to the system?
have to build a new probe file first. In the probe dialog box type in a new tip name, click on the box at the bottom left, then use the drop down box above it. Find your wrist and select it. Next find the components that connect your stylus. then last find your stylus. The graphic should look just like the one on your CMM. Then calibrate it.
I want to basic information about cmm video
would you want to buy a new cmm?
sir please make video on countura G2 with RDS -CCA styli calibration step by step detailed
ua-cam.com/video/7sgNzpwEovU/v-deo.html
Hanzhen hamonic drive gear , strain wave reducer,
robot joint , over 30 years experience
nice vid
@Leslie Sinnock can you pls show us about importing drawings. i dunno if thats available in PCDMIS 2011. :)
Good idea. I'll try to get that up for you soon.
Plz send me the DMIS software calibration process
Hi! I’m new to Cmm programming. Quick question, is this calibration refer to a R-Test??
I think the video is calling stylus tip qualification 'calibration'.
Sir,please aplod how to create new stylus rak in cmm Ziess
thanks
very usefull !!!
Manually having to move the probe is horrible. Luckily I don’t have to work like that.
Don't you mean stylus system qualification. Have a look at ISO 10360-1.