Combustion Analysis Refresher--Nov 2016

Поділитися
Вставка
  • Опубліковано 7 лип 2024
  • Wade gives training on proper probe placement for combustion analysis of water heaters and furnaces, and explains the combustion analysis tape
  • Навчання та стиль

КОМЕНТАРІ • 22

  • @wolf_crown
    @wolf_crown Місяць тому

    Just got out onto the field trying to run combustion but didn’t quite understand as much as I do after watching this video. Thank you for teaching this! Very educational

  • @tommykelley8118
    @tommykelley8118 Рік тому +2

    This video covers it all in language we can understand. Great lecture.

  • @jhuh1758
    @jhuh1758 4 роки тому +4

    the best lecture on combustion..

  • @Johnlee0513
    @Johnlee0513 5 років тому +3

    Great and informative, well presented and I now understand the tapes to their utmost. Thank you for your concern regarding complete understanding of the combustion process as pertains to the meters.

  • @usahoangsatruongsa
    @usahoangsatruongsa 6 років тому +5

    Thank you so much for a clearly explanation

  • @AnchorSnake
    @AnchorSnake 6 років тому +4

    Thank you for posting this video and explaining the numbers on the tape. Well done Sir, I learned a lot. Thanks again.

  • @phillipjoy8191
    @phillipjoy8191 5 років тому +1

    Great video

  • @OnlySnipe852
    @OnlySnipe852 3 роки тому

    Great presentation

  • @user-cm9yo8ep3v
    @user-cm9yo8ep3v 13 днів тому

    You mentioned a 200 slide presentation. Any way you could tell us or provide it where it is thanks and have a great day

  • @danielgallagher3608
    @danielgallagher3608 Рік тому

    I have no idea how this came up in my recommendation, the UA-cam algorithm strikes again

  • @natep1661
    @natep1661 4 роки тому +1

    Is the ONLY reason you don't wanna drill in a horizontal section of flue for high efficiency furnaces because of condensation risks?
    What of you drilled into the side or the top facing down into said pipe? Little to know risk of condensation issues right? Would the readings still be accurate and acceptable?

  • @nbrown2728
    @nbrown2728 4 роки тому

    Good job

  • @christopherdiaz3277
    @christopherdiaz3277 5 років тому +5

    Ha! At 13:45 the kid was clearly not listening! ..lol How did nobody have any questions throughout the whole class??

  • @madayanmuttal886
    @madayanmuttal886 3 роки тому +1

    Soot is actually CO

  • @mitchdenner9743
    @mitchdenner9743 5 років тому +1

    Good chit

  • @tyl8ter
    @tyl8ter 4 роки тому

    31:01...co (af)= co ppm * 20.9/(20.9-o2)….I believe...……

  • @madayanmuttal886
    @madayanmuttal886 3 роки тому

    O2 and CO2 are not inversely proportional

  • @madayanmuttal886
    @madayanmuttal886 3 роки тому

    Soot is not H2

  • @mr.invisible3770
    @mr.invisible3770 Рік тому

    What about probe placement on a Rooftop package unit?

    • @MarkCarpenterHVAC-me2jg
      @MarkCarpenterHVAC-me2jg 8 місяців тому

      Place it as far in the exhaust as you can without hitting the inducer fan or melting the handle. The Sauermann analyzers also have a flexible handle that might be helpful in some situations.

  • @RockoRocko-rz7kx
    @RockoRocko-rz7kx 3 роки тому

    Great video