DIY Underground Electrical Service

Поділитися
Вставка
  • Опубліковано 2 лют 2025

КОМЕНТАРІ • 126

  • @thepressedpig5397
    @thepressedpig5397 Рік тому +2

    I'm doing this now as a 54yr old female. I really liked how you put the wood on top to glue your conduit! That is going to help me as I'm finding it hard to glue in the trench! So Thank you for making the video!❤❤

    • @LewisRenovation
      @LewisRenovation  Рік тому +1

      Good luck! Hope it goes well. Feel free to reach out if you need anything else

  • @alfonsoaguilar9612
    @alfonsoaguilar9612 Рік тому +2

    Love the Voice over over edits and the fact you had fun. Appreciate your time and sharing the video.

  • @dustinphillips3664
    @dustinphillips3664 2 роки тому +6

    That vacuum trick was pretty genius! I will definitely be giving that a try in a few weeks.

  • @mikepagan7529
    @mikepagan7529 2 роки тому +3

    Fixing to do 450’ thank you for sharing this!! Was a great help!!

  • @roush211
    @roush211 3 роки тому +4

    Ran 1/2 mile 4" water pipe in floresville tx with my dad when I was about 19-20. Thought hey man it's a cloudy day so took shirt off. Longest day of my life followed most severe sunburn ever lol

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      I seem to make the cloudy day mistake once every spring. Someday I'll learn. You still in Texas?

    • @roush211
      @roush211 3 роки тому

      @@LewisRenovation I am, actually selling house in san antonio next month and building on my land in floresville.

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      Good luck with the new house. I'm sure it will be nice to get out of the city

    • @roush211
      @roush211 3 роки тому +1

      @@LewisRenovation ty, looking forward to getting back out to the country and not driving back and forth since my son finally finished school. Good luck as well

  • @ClayAdams-zj8yf
    @ClayAdams-zj8yf 6 місяців тому

    37 year electrician. Watching you dig out the back fill where the trenches met reminded me of why we use excavators. Our local utility will only allow 2 sweeps. One at the pole and one at the structure.

    • @LewisRenovation
      @LewisRenovation  6 місяців тому +1

      The reason why I did it myself was because they’d only install two sweeps but would allow 4 if I did it. Thanks for the comment!

    • @clayadams2068
      @clayadams2068 6 місяців тому

      So they provided and pulled the wire but it was on you if it got hung up?

    • @LewisRenovation
      @LewisRenovation  5 місяців тому

      @clayadams2068 yes, they said I’d have to fix it if something went wrong

  • @qualityassurance9523
    @qualityassurance9523 2 місяці тому

    just got slammed with a burned out neutral and a bid for 10000 to fix not including the electric company itself thank you so much for posting,

  • @STR8HOLDIN
    @STR8HOLDIN 3 місяці тому

    Thanks , I am looking for a piece of land now and I wanted to have my power underground. This video will help me in the future. Thanks

    • @LewisRenovation
      @LewisRenovation  3 місяці тому

      Good luck finding your land. It always feels expensive and 10 years later you think it was a steal

  • @flowerpt
    @flowerpt 9 місяців тому +1

    You made an excellent video. Thanks for recommending the Cobra pliers! Also, tell your wife the Internet thinks she's amazing. 😊

  • @darinjuliesims354
    @darinjuliesims354 Рік тому +1

    Dude you crack me up. Great video though. Love the DIY attitude. Ya my inspectors didn't even stop, it was a drive by I got the all clear....LoL

  • @morepower3242
    @morepower3242 3 роки тому +2

    Thanks for the video very thorough I like it man I appreciate it because I needed some of that information for myself

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      Good luck with your project. Thanks for commenting

  • @tonkatoytruck
    @tonkatoytruck 3 роки тому +1

    Nice to not have to worry about gas lines, internet, fiber optic, power lines, landscape plumbing, etc. AND have to do it by hand. You make it look so easy. haha

    • @LewisRenovation
      @LewisRenovation  3 роки тому +2

      Everything looks easy with the right right video editing. 😀 Thanks for the comment

  • @dash1482
    @dash1482 2 роки тому +2

    Awesome job!! Ill be doing the same thing in a few months and this really helps!!

  • @JustAnotherDudeOnYoutube
    @JustAnotherDudeOnYoutube 3 роки тому

    Great video ! Str8 forward
    Appreciate it
    Doing this now in southern Oklahoma

  • @TheSpatulaCity
    @TheSpatulaCity 2 роки тому

    Cool. That was a neat tip to use a shop-vac and a plastic bag to pull the string through.

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      Thanks for the comment. Are you working on a similar project?

  • @greenharvestproductions6743
    @greenharvestproductions6743 2 роки тому +1

    Wonderful video wonderful video I don't know what state you're in I'm in the state of Florida and usually go up to 3 ft deep because we have a lot of sand what size wire were you putting underneath the ground excuse me let me make correction on that what size wire did the power company put in there size 1 three wires

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      I think the cable was 1/0 but I'm not 100%. Thanks for the comment!

  • @bethlewis4500
    @bethlewis4500 4 роки тому +1

    Yay! The wires didn't get stuck. Like the aerial shots.

    • @LewisRenovation
      @LewisRenovation  4 роки тому

      Thanks. I had an amazing helper!!

    • @phillipwhittaker2389
      @phillipwhittaker2389 3 роки тому

      That sucks that you were going to be liable if the wire got stuck in the conduit, you would think you could pull the wire without having the conduit buried...

  • @joseenriquez1328
    @joseenriquez1328 2 роки тому

    2:10 😂😂😂 I’m sure you did a better job than professionals!!! I’m sure they do a lot of wrong things just to save time and a few dollars!!! Great job Man! 👍🏻

  • @mikepagan7529
    @mikepagan7529 2 роки тому +1

    Did you have to buy the electrical cable???

    • @LewisRenovation
      @LewisRenovation  2 роки тому +3

      I got the cable for "free" because it was from an existing transformer within 300' of the house. But I had to pay for 2200 ft of high voltage from the street to the transformer when I had it put in 5 years ago

  • @Yougotthis104
    @Yougotthis104 Рік тому

    Thanks your video taught me a lot

  • @rudyardgomeas6042
    @rudyardgomeas6042 2 роки тому +1

    Why is it the glue and primer lids always get stuck, can't they make better caps, like everyone else.

  • @greenharvestproductions6743
    @greenharvestproductions6743 2 роки тому

    How deep did you have to bury the electrical PVC two and a half inch how deep was it required to bury the underground

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      I was required to bury the conduit 24 inches deep

  • @ElevatorWasher5000
    @ElevatorWasher5000 Рік тому

    Can this lower power outages too

    • @LewisRenovation
      @LewisRenovation  Рік тому

      Unfortunately no

    • @flowerpt
      @flowerpt 9 місяців тому +2

      well, if you have trees that could fall on an aerial wire from a pole to the house.

    • @ElevatorWasher5000
      @ElevatorWasher5000 9 місяців тому

      @@flowerpt I have a lot of trees and get random power surges when branches fall

  • @SUPERHEAVYBOOSTER
    @SUPERHEAVYBOOSTER 2 роки тому +1

    So progressive of you to have your wife be the head of your household (the boss).

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      Yeah. Just don't let my fellow Texans know I'm "Progressive"

  • @Dallasburtonmusic
    @Dallasburtonmusic Рік тому

    can you tell me what kind of wire you used? 4 aug? how many? 3 or 4 wire. Thanks!

    • @LewisRenovation
      @LewisRenovation  Рік тому

      I’m sorry. The utility contractor ran the wire so I’m not sure

  • @jfromtn7410
    @jfromtn7410 2 роки тому

    hey fixing to do the same thing.i plan on using a ditch witch.only 70 ft though lol.wat do you think

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      Really depends on soil type but should work fine

  • @farmerbob728
    @farmerbob728 Рік тому

    Great video.. Seems your contractor really didn't want the job??? Seems to tell you a lot of what he won't do. Then after he runs the wire... you're responsible for his mess up ??

    • @LewisRenovation
      @LewisRenovation  Рік тому +1

      The contractor works for the electric company so they get to do almost whatever they want. Thanks for the comment

  • @BubbaIXI88
    @BubbaIXI88 2 роки тому

    awesome video

  • @The11AMARK
    @The11AMARK 4 роки тому

    Thanks! I’m considering this on my build

  • @liamsilver4843
    @liamsilver4843 3 роки тому

    nice job Lewis Renovation & Repair. So Basically the electric co takes care of the rest? you just put all the pvc pipe?

    • @LewisRenovation
      @LewisRenovation  3 роки тому +2

      Yes, I had to install the pipe and pull tape, get it inspected, and the backfill the trench. The utility did the rest

  • @dave_in_florida
    @dave_in_florida Рік тому

    How much amp service did you pull through?

  • @cityslickerf1507
    @cityslickerf1507 Рік тому

    What they run? 4/0 4/0 2/0?

  • @fixitman8028
    @fixitman8028 4 роки тому

    Great video. Thanks for posting

  • @gladdenhandymanllc962
    @gladdenhandymanllc962 2 роки тому

    This guy seems like an absolute riot.

    • @LewisRenovation
      @LewisRenovation  2 роки тому +1

      Thanks! Life is better when it's light hearted

  • @timwilson3150
    @timwilson3150 4 роки тому

    So you didn’t have to pull a mandrel through? Not 3” conduit? Not 3’ deep trench?

    • @LewisRenovation
      @LewisRenovation  4 роки тому

      No mandrel, 2.5", 2 feet deep. All specified by the utility

    • @timwilson3150
      @timwilson3150 4 роки тому

      @@LewisRenovation In CA it’s 3” conduit buried 3’ deep and we have to pull a mandrel through it with the utility watching. It sucks.

    • @LewisRenovation
      @LewisRenovation  4 роки тому +1

      I've visited California a couple times and it's a beautiful place, but I hear all the regulations are difficult to deal with. Take care!

    • @timwilson3150
      @timwilson3150 4 роки тому +1

      @@LewisRenovation Minimum 3’ trench which PG&E actually has to come out and measure. Then a 3” substrate of special PG&E sand, which they also come out to check. Only then can we run our 3” conduit. Then we have to cover it with another 6” of pre approved PGE sand and they check it again. Only then can we backfill the trench provided there’s a warning electrical tape buried above the conduit run. It’s ridiculous.

    • @ammonautele3804
      @ammonautele3804 Рік тому

      Hawaii mandrel is required as well. Also 6in clearance on both sides of the conduit…. Every state differs I guess

  • @itsbigdon
    @itsbigdon 3 роки тому

    no primer?

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      It's not required with conduit

    • @william.shilling2969
      @william.shilling2969 Рік тому

      The primer actually eats away the pvc. It's not like plumbing. Plus you should use only pvc conduit cement.

  • @robertbloodworth6342
    @robertbloodworth6342 3 роки тому

    What do you figure that cost you per foot??

    • @LewisRenovation
      @LewisRenovation  3 роки тому +2

      The utility paid for the actual cable, I probably have $600 in rental and material cost. So cost me $2/ft plus cable

    • @Brandon-td2sm
      @Brandon-td2sm 2 роки тому

      @@LewisRenovation That's awesome. Prolly saves yourself 10x that doing it yourself.

  • @idahoduckhunter
    @idahoduckhunter 4 роки тому +1

    Very good info, thanks

  • @BayAreaElectric
    @BayAreaElectric 3 роки тому

    Nice video. In my area of California we would have had to use swedge couplings, which are much deeper. Also, we would have had to install 3" PVC. Well, anyway it worked. Good job.

    • @LewisRenovation
      @LewisRenovation  3 роки тому +2

      Thank you. I've visited California a couple times. Beautiful place but I understand there's lots of regulation.

  • @Amarillobymorning777
    @Amarillobymorning777 Рік тому +1

    GR8 VIDEO CLIP

  • @lancec6342
    @lancec6342 2 роки тому +1

    Schedule 80 is better protection if someone decided to dig in the future it would be less likely to penetrate

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      I’m sure that’s true. Thank you for the comment

  • @tori5977
    @tori5977 4 роки тому +1

    Love this video!

  • @lupacini
    @lupacini 5 місяців тому

    GOD BLESS.

  • @william.shilling2969
    @william.shilling2969 Рік тому

    Be glad you didn't have to use 36 in dia. rigid sweeps.

  • @toddwikel3849
    @toddwikel3849 3 роки тому

    I'm getting ready to do the same thing outside of Dallas. How much did you save by running the conduit yourself? What was your cost breakdown and Oncor i stallation allowance? Thanks, great video.

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      It cost me roughly $400 in materials and $200 to rent the trencher. I think Oncor world have done it for free but they would have put the meter in the front of the house. When I ran electricity to my shop next door, they didn't charge anything for running from the transformer to the building. I did have to pay $22k to get electricity 2000 feet off the road to the transformer.

    • @toddwikel3849
      @toddwikel3849 3 роки тому

      @@LewisRenovation was the 22k after you ran the below ground conduit? How much did they charge you per foot for the primary cabling?

    • @toddwikel3849
      @toddwikel3849 3 роки тому

      @@LewisRenovation it appears Oncor ran the 2k feet above ground. Did they give you an above ground cost breakdown or just a cost per foot?

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      I had to pay for the electricity to get from the existing line on the county road back 2100 feet to near where our house was going to be. This was 4 years ago. Once I paid the $22k for this, Oncor ran the wire from the last pole with the transformer underground to the shop for free (~250 feet) and also ran the wire to the house for free (~220 feet) but I did the conduit since I had a location that wasn't direct.

    • @LewisRenovation
      @LewisRenovation  3 роки тому

      I got a flat quote, but it was basically #10 / ft. I think the number of poles they have to put in is number 1 factor. For mine, they had to put in 6

  • @timothyletwin5911
    @timothyletwin5911 3 роки тому

    Underground cable would have been way easier and cheaper no?

    • @LewisRenovation
      @LewisRenovation  3 роки тому +1

      They wouldn't allow underground cable without conduit

    • @timothyletwin5911
      @timothyletwin5911 3 роки тому

      @@LewisRenovation That's too bad. Is that an earth quake thing in your state codes?

    • @LewisRenovation
      @LewisRenovation  3 роки тому +2

      @@timothyletwin5911 no earthquakes here since the dinosaurs. I was given a spec sheet by the utility distribution company and I just followed it. don't really know the reason why.

  • @bigtroll8249
    @bigtroll8249 8 місяців тому

    The pros would trench w an excavator and 36 - 48" bucket

  • @CrankyGamer85
    @CrankyGamer85 2 роки тому

    I would have ran the wire while putting the conduit together. Save some money$$$$

    • @LewisRenovation
      @LewisRenovation  2 роки тому

      I didn't have the choice to run the wire myself

    • @william.shilling2969
      @william.shilling2969 Рік тому +1

      You have to run conduit till completed. A complete system, then you pull wire. It is stated in the NEC.

  • @tylerguillory9348
    @tylerguillory9348 3 роки тому

    Peep the crawfish @1:50

  • @warren-e-dee2671
    @warren-e-dee2671 9 місяців тому

  • @airmsylenam954
    @airmsylenam954 3 роки тому

    Can Americans do the job without wife permission? 😂😂😂