Stator Design_ 5 HP_ Part 1 |Design of Three Phase Induction Motor|

Поділитися
Вставка
  • Опубліковано 2 січ 2025

КОМЕНТАРІ • 12

  • @samuelwadie8219
    @samuelwadie8219 8 місяців тому +1

    Hello Sir
    thanks for your video and it was helpful to understand the 1st step for design motor and let me discus some issue:-
    1- in Co. equ. u consider Bav,AC,Kw, BUT i saw other video and doc. mentioned that u have consider also in Co. equ. the ( eff. and power factor ) . so i have a conflict . need explanations?
    2-u have calculate no. of turns , final value, Tph = 372 . does it for each phase?
    3- why u didn't tell us the cross section area of the selected wire needed for 372 turns? i need to know how i can calculated?
    4- when u find the values of D; L each D= 128mm ; L= 100 mm and i checked for IEC std. for 5 HP ( actually 5.5 HP for siemens motors, frame size 132S) - i checked the L/D in manuf. std in Germany produced stator and rotor and acc. to their std D= 200 mm and L= 125mm- so how can solve this issue?

  • @kanand9526
    @kanand9526 Рік тому +1

    Sir I want to talk about the project work with you can you give me an opportunity?

  • @basantsingh8305
    @basantsingh8305 Рік тому

    Sir please explore the design of 3 phase traction 3032rpm,2027 VAC

  • @kishoreseepana1347
    @kishoreseepana1347 4 роки тому

    Hai sir
    How to assume Bab =0.5
    ac = 27000
    Please tell me sir

    • @anishvora6264
      @anishvora6264  4 роки тому +1

      It is given in the design numerical that assume Bav = 0.5 & ac = 27K

    • @anishvora6264
      @anishvora6264  4 роки тому +1

      If it is not given and based on only specification if we need to design, then based on KW rating we can choose standard values of specific electric as well as specific magnetic loading

    • @kishoreseepana1347
      @kishoreseepana1347 4 роки тому

      @@anishvora6264 Thanks for repaly sir

    • @ramgatigupta6525
      @ramgatigupta6525 2 роки тому +1

      sir what formula used in company for motor winding

    • @samuelwadie8219
      @samuelwadie8219 8 місяців тому

      @@anishvora6264
      Hello Sir
      thanks for your video and it was helpful to understand the 1st step for design motor and let me discus some issue:-
      1- in Co. equ. u consider Bav,AC,Kw, BUT i saw other video and doc. mentioned that u have consider also in Co. equ. the ( eff. and power factor ) . so i have a conflict . need explanations?
      2-u have calculate no. of turns , final value, Tph = 372 . does it for each phase?
      3- why u didn't tell us the cross section area of the selected wire needed for 372 turns? i need to know how i can calculated?
      4- when u find the values of D; L each D= 128mm ; L= 100 mm and i checked for IEC std. for 5 HP ( actually 5.5 HP for siemens motors, frame size 132S) - i checked the L/D in manuf. std in Germany produced stator and rotor and acc. to their std D= 200 mm and L= 125mm- so how can solve this issue?

  • @mukeshjoshi1378
    @mukeshjoshi1378 3 роки тому

    Sir ji Kya ap Hindi me Samaj sakte ho?