  • Learn how to perform recommended maintenance on Fisher’s MR95 series regulators during this step-by-step video. The MR95 Series offers easy maintenance with seating parts that are easily accessible by removing the plug on the bottom of the regulator.
    Topics included:
    Valve plug guide inspection and torque specifications
    Inspecting and replacing orifice
    Properly disassembling and assembling spring case
    Inspecting diaphragm and assembly
    Removing and inspecting the pusher post
    Lubricating and inspecting O-rings / elastomers
    MR95 Series regulators are compact, large-capacity (up to 1,000 psig), direct operated pressure reducing valves. The versatile MR95 can be used with all industrial process media, including air, steam, gas, water, liquids / oils, and oxygen. Special constructions are available for handling sour gases, seawater, cryogenics and superheated steam. (NACE International Standards)