On delay timing control circuits

Поділитися
Вставка
  • Опубліковано 2 січ 2020
  • Time delay relays are very important in a motor control circuit that requires sequence starting. Utilizing On delay relays allows you to time starts between motors. This video will explain how this is possible.
    👉Join the Electric Academy and receive a free PDF of online resources for electricians:
    np378.infusion...
    🤜Here is how you can offer your support to all the work of the Electric academy:
    / electricacademy
    For as little as $1 a month you can help keep all the resources free and awesome (Plus you get swag!).
    🤳For access to the free online courses for electrical theory:
    app2ceo.thinki...

КОМЕНТАРІ • 8

  • @user-wv9vo4gp7c
    @user-wv9vo4gp7c 2 роки тому

    a well thought out explaination

  • @aboalhassenahmed7270
    @aboalhassenahmed7270 2 роки тому +1

    The auxiliary coil M
    How it will hold if it in normally closed ?
    I think It will be in open state ?

  • @tg9507
    @tg9507 Рік тому

    Very informative. I’m a woodworking guy, and a novice in electrical automation. I am trying to automate my shop vac filter cleaning. I have a 2kw 220V shop vac, and a small 200W motor that runs the filter cleaner. I start and stop the shop vac with a remote controller. Today I run the shop vac filter cleaner manually. I would want to run it automatically with a time delay, such that it starts 5 sec after shut down of shop vac, and runs for 10-15 sec, and then shuts down. This repeats after each time I use the shop vac. Do I need a full set of interlocking contactors, relay and timers to ackomplish my goal? Can you guide me, or better still, could I ask you to create a UA-cam video on this topic, as I am sure I am not the only one struggling with this task.

  • @pelicanman2315
    @pelicanman2315 2 роки тому

    Greetings to you sir. Great tutorial. Can you do two of this circuit in one so that when one motor stops, the other starts? 3 phase.

  • @salsal1967
    @salsal1967 2 роки тому

    Hello Thanks for the video. Can you help me on the following:
    I have 2 Air-conditioning units which I don't want to have them turn on (takeoff) at the same time as if that happens the main circuit breaker switch trips. Therefore I need some sort of a delay-On device that receives signals from the two thermostats of the two AC units and then pass them to there assigned magnetic contactors one after the other with a time difference between the two to prevent the units from turning on at the same moment which will lead to MCB tripping.
    Waiting for your valuable answer.
    Regards,
    .

  • @mrwega44
    @mrwega44 3 роки тому

    if i remove the contact M and keep the timer will the timer still count 5 seconds if i press for 1 sec i will be left with 4 seconds or will it restart waiting for a continuous 5 seconds

  • @aaronflores5659
    @aaronflores5659 3 роки тому

    Dont you need a cr1 to hold the start in place? Or does the time relay hold the botton closed?

  • @ushaandusha
    @ushaandusha 6 місяців тому

    You are technical but not clear may be you should have a better video