API 650 STORAGE TANK BOTTOM, ANNULAR PLATE REPLACEMENT LOW COST METHOD FOR BEGINNERS AND EXPERTS

Поділитися
Вставка
  • Опубліковано 4 вер 2021
  • API 650 storage tank bottom and annular plate repair, replacement, easy, low cost and fast method tutorial for fitters, supervisors and engineers. Donate paypal.me/Technicalstudies502
    This channel explain about storage tank, pressure vessels, piping fabrication, erection, welding, piping isometric,
    ndt, welding, cutting , pipe fit-up, fabrication, erection, elbow cutting, elbow center calculation, welding process, valves,
    pressure gauge, hydro testing details, welding calculation, pipe supports, equipment, pumps, Trigonometric formula
    application, pipe offset calculation, fitter, fabricator training etc. @technicalstudies.

КОМЕНТАРІ • 60

  • @nobodymane185
    @nobodymane185 2 місяці тому +2

    Very informative video and interesting methods shown. Thank you for posting this video. It’s cool to see how all of the techniques and stuff is executed.

  • @sureshanjali7679
    @sureshanjali7679 2 роки тому +1

    What a great work 👌

  • @redmanizer31
    @redmanizer31 17 днів тому +1

    More vids please

  • @pushpapanicker8547
    @pushpapanicker8547 2 роки тому +2

    Superb good job 👌👌👌👍👍👍

  • @gfhash4319
    @gfhash4319 2 роки тому +1

    Great thanks, great thanks, great thank.

  • @ravimishra1906
    @ravimishra1906 2 роки тому +1

    Great work

  • @ratishtyre4371
    @ratishtyre4371 2 роки тому +1

    Informative

  • @vinesh6890
    @vinesh6890 2 роки тому +1

    Amazing 👍🏼

  • @akshaichandran3806
    @akshaichandran3806 2 роки тому +1

    great work

  • @user-kv1ze1jj7n
    @user-kv1ze1jj7n 4 місяці тому +1

    Great video. What references would you recommend for determining the minimum required size beams needed for the stiffeners? API 653 doesn't seem to cover much beyond stating they may be required.

    • @technicalstudies.
      @technicalstudies.  3 місяці тому

      Thank you bro. As you told, minimum size is not mentioned in the cods. Structural size depends, the diameter, slope, loads on the roof, ind speed etc

  • @aliihsan8374
    @aliihsan8374 Рік тому +1

    wonderful video

  • @Tural1036
    @Tural1036 2 роки тому +1

    Thanks for this

  • @ghaah
    @ghaah Рік тому +1

    Thank you soo much

  • @chandrashekharpanicker8659
    @chandrashekharpanicker8659 2 роки тому +1

    Superb

  • @datinbin
    @datinbin 2 роки тому +1

    What cutting method was used to cut the old annular away so that there was a clean straight profile on the bottom of the shell plates for welding the new annular welds. Are there photos of this work somewhere? You must also take care not to cause a differential settlement situation or cause damage to the shell bottom plate when driving in wedges. Interesting approach.

    • @technicalstudies.
      @technicalstudies.  2 роки тому

      We used the gas cutting method, fortunately, our gas cutting technician was highly experienced in these types of jobs. He put a 10 thick flat bar near the corner welding and moved the cutting torch horizontally. The cutting was very smooth. Unfortunately, there was not any photograph left.

  • @saranyadevi6468
    @saranyadevi6468 Рік тому +1

    super bro

  • @samik9600
    @samik9600 2 роки тому +2

    API 650 is for constructing a new above ground liquid storage tank while API 653 is for the maintenance of an API 650 to determine whether the tank fit for continued service.

    • @technicalstudies.
      @technicalstudies.  2 роки тому

      Bro, you are right, but for some corrections, API 650 stands for atmospheric pressure. API 653 stands for whether the tank fits for continued service. Thank you for the comment.

  • @essamhassan5810
    @essamhassan5810 16 днів тому +1

    How to apply RT on weld seams joining annular plates together ?

    • @technicalstudies.
      @technicalstudies.  13 днів тому

      I am sure, you know the answer. Mostly the client will not ask you, when you repare and replace the annular plates.

  • @mugovehillary7444
    @mugovehillary7444 2 роки тому +3

    hi this is interesting ,is there a course that i should to be a certified storage tank repair

    • @technicalstudies.
      @technicalstudies.  2 роки тому +2

      Sorry, Bro. To my knowledge, I don't know any institution conducting certification courses for tank repair.

    • @mugovehillary7444
      @mugovehillary7444 2 роки тому +2

      @@technicalstudies. okay thank you so much

  • @bouhaniafaycal9523
    @bouhaniafaycal9523 2 роки тому +1

    What is the correct scissor seal installation method in floating roof storage tanks for hydrocarbons?

    • @technicalstudies.
      @technicalstudies.  Рік тому

      Bro, sorry for the late reply. Each and every sealing has its advantages and disadvantages. I am only a fabrication engineer.

  • @kriswilliams9375
    @kriswilliams9375 2 роки тому +2

    how do you perform the weld where the 2 annular plate is directly below the shell?

    • @technicalstudies.
      @technicalstudies.  2 роки тому

      Thank you for the comment.We used to push two wedgs on both side of the joint between the shell and annular plate, making a gap of 20 to 25mm.

    • @TheTanker_69
      @TheTanker_69 2 роки тому +1

      @@technicalstudies. How to do RT for Annular joints

    • @technicalstudies.
      @technicalstudies.  2 роки тому +1

      @@TheTanker_69 Hai Ketsana. Not many clients, ask for RT, in this type of replacement methods. Instead, UT and PT is possible. In case the client ask for RT is a must, then we need to change the LOW COST to HIGH COST jacking method. Thank you.

    • @ghaah
      @ghaah Рік тому

      @@TheTanker_69 where do you keep film for RT

  • @subramanyas8602
    @subramanyas8602 7 місяців тому +1

    It is not clear on removeal of the existing annular bottom plate when wedge load is exerted on existing plate , also tnak height is reducing by 25 mm , will changes the position of nozzles

  • @mapengineering4524
    @mapengineering4524 2 роки тому +1

    If your tank has a false button can you use this method

  • @kevinnazeraj1799
    @kevinnazeraj1799 2 роки тому +1

    So you have to raise the tank with crane or hidraulik pistons

    • @technicalstudies.
      @technicalstudies.  2 роки тому

      Bro. it depends on your pocket 🤣

    • @technicalstudies.
      @technicalstudies.  2 роки тому +1

      If you have dollars, I will recommend the jacking method. This is a low-cost method.

    • @kevinnazeraj1799
      @kevinnazeraj1799 2 роки тому

      Yes but if the tank weight is 120 tons, is not so safe to lift it with crane right ?

  • @venthangeorge5303
    @venthangeorge5303 Рік тому +1

    How to weld annular to annular But Joint while Shell plates rest on Annular plate??

    • @technicalstudies.
      @technicalstudies.  Рік тому

      drive, wedges, between the shell and the annular plate, you will get enough gap for welding, use a needle grinder for cleaning.

  • @vipinvidhyadharan7536
    @vipinvidhyadharan7536 Рік тому +1

    How you remove the existing annular plate with bothe side welding

  • @centerenamel905
    @centerenamel905 2 роки тому +1

    Great work