How to repair Solar Inverter 3Kva/3000 watt: AC charger is damaged ,shorted

Поділитися
Вставка

КОМЕНТАРІ • 36

  • @rustamjoya8452
    @rustamjoya8452 2 роки тому +1

    very nice and detailed repair. Maybe next time, you can feature DALY bms repairs also, :)

  • @mickeysherman4268
    @mickeysherman4268 2 роки тому

    I really admire your good work...

  • @Dc_tech386
    @Dc_tech386 9 місяців тому

    This module of mppt inverter is designed for soft switching so for those wondering why two transformer the second one is ahh current control for current spikes to stop igbt from cross conditions when in first and second cycle

  • @Dutch_off_grid_homesteading
    @Dutch_off_grid_homesteading 2 місяці тому

    Heya nice repair 1st time seeing you use 2 caps in parrallel to replace 1 cap that reall DIY lol

  • @rmmlakshan3895
    @rmmlakshan3895 2 роки тому +1

    Sir, every time you post a video, we look forward to seeing your video, sir can you make a growatt off grid inverter repair videos ..

  • @dashley2525
    @dashley2525 7 місяців тому

    My 10.2 PowMr will harvest so Load is being met but battery is not being charge till about 1800 w. The PV input readout is an arbitrary .5 kw till about 1800 w PV input. No one has had a clue why so far. A replacement 6.2 kW PowMr works perfectly. So the issue is surely in the 10.2 unit. Issue existed at initial startup.

  • @letuananh122
    @letuananh122 Місяць тому +1

    Can you tell me what the cause of the damage is?

  • @abduljabbargulammohammed2974
    @abduljabbargulammohammed2974 2 роки тому +1

    hello good morning sir
    I saw your work through UA-cam, it is very appreciated
    I have 3kw REVO II ongrid hybrid inverter battery charging problem not turning off blinking continues but when i measure with clamp meter it is showing 4Am current
    on inverter show 30Am about this issue please help me

  • @bengeluutlengel6939
    @bengeluutlengel6939 11 місяців тому +2

    Also problem here with smh 3k. It does not charge battery from pv. No error code., no internal damage. Everything else works okay only problem is not charge from solar.. Any help is welcome

    • @bengeluutlengel6939
      @bengeluutlengel6939 11 місяців тому

      Fetts looking okay, no short. Lcd says pv 31 volts. No support from seller.. Inverter is new

  • @User_987dfg
    @User_987dfg 2 роки тому +1

    Good work sir thank you

  • @Akram101
    @Akram101 2 роки тому +1

    Very nice 👍

  • @ВикторО-э1г
    @ВикторО-э1г Рік тому +1

    Good time of the day, my problem is that the Uc3843 PWM does not start, I changed everything else to PWM +7.5v

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Рік тому

      thank you dear friend
      Please join our channel to contact our technical team
      ua-cam.com/video/a8uRXPejtvo/v-deo.html

  • @myonlineshopping7429
    @myonlineshopping7429 Рік тому +1

    What is the root cause of this problem?
    AC input volt surge?
    Mismatch battery amps?
    Bad design??

  • @Qaiserhayatkhan
    @Qaiserhayatkhan 2 роки тому +1

    Nice

  • @fabiuh991
    @fabiuh991 2 роки тому +1

    Hello sir, can you please confirm the big resistor value of 0.015ohm near the offline psu and the voltage detector ic part number on the back? I am detecting a short after the 5v regulator and the "voltage detector" gets hot. I might have to replace them both.
    Thank you for your videos

    • @boatengnketia1114
      @boatengnketia1114 Рік тому

      Sir I am having some challenges on my converter and this is the problem the battery out put is OK displaying 13.5V but when if you from the AC side the is no voltage on the output for the AC, what do u pls think might be the problem

    • @fabiuh991
      @fabiuh991 Рік тому

      @@boatengnketia1114 does the inverter turn on?

    • @boatengnketia1114
      @boatengnketia1114 Рік тому

      @fabiuh991 yes it do turn on and displays the voltage of the battery, but does not display the input a d the output voltage

    • @fabiuh991
      @fabiuh991 Рік тому

      @@boatengnketia1114 if the inverter does not display any error, maybe its just some kind of blown fuse or disconnected wire. Check for output voltage directly on the board passed the output terminals

  • @giovannis5914
    @giovannis5914 Рік тому

    hello o a 3kva 24v hybrid inverter I exploded 2 mosfets in the 220 circuit in the output I changed 4 mosfets but it still gives me error 06 connecting the 220 works normal it gives me 220 output but connecting only the 24v it doesn't exchange 220 ???????? I don't notice any burns or blackened circuits

  • @rmmlakshan3895
    @rmmlakshan3895 2 роки тому +1

    sir i having one inverter ,it's not going to bypass on AC mode and it's not charging also.sir can you help me.

  • @dashley2525
    @dashley2525 7 місяців тому

    Does anyone know of a place to send a hybrid inverter for repairs?

  • @nyanphyoaung5661
    @nyanphyoaung5661 2 роки тому

    can I ask you some question? Lighitng strike can casue inverter not working?

  • @danieladusei573
    @danieladusei573 2 роки тому +1

    Hello sir please I need your help I have mast solar inverter 5kva 48v and it's not working because there is a fault code 53 I have replaced all the igbt and the most fest but still same thing please I need your help hope to hear from you soon

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  2 роки тому

      Dear friend
      Please join our channel
      To contact you
      ua-cam.com/video/a8uRXPejtvo/v-deo.html

    • @danieladusei573
      @danieladusei573 2 роки тому +1

      Ok sir thank you I will join it

    • @danieladusei573
      @danieladusei573 2 роки тому

      Hello sir please you asked me to join the channel and you will contact me but I have joined but I have not seen anything

  • @dlladlla22
    @dlladlla22 5 місяців тому

    ❤❤❤❤❤

  • @rmmlakshan3895
    @rmmlakshan3895 2 роки тому +1

    Sir can you help me again one more problem

  • @Apo5308