OCT Technologies: Swept Source vs. Spectral Domain

Поділитися
Вставка
  • Опубліковано 31 тра 2024
  • In this webinar, Drs. Dierck Hillmann and Sebastian Schäfer of the Thorlabs Optical Coherence Tomography (OCT) Applications Team will review the theory behind Swept Source and Spectral Domain OCT technology. They will highlight the technical differences and present several application examples that show the pros and cons of each technology.
    To view our full line of OCT products, please visit www.thorlabs.com/navigation.c....
    For more webinars, visit www.thorlabs.com/newgrouppage....
    0:00 Introduction
    3:27 Section 1: Time Domain of OCT
    5:36 Section 2: OCT Terminology
    11:50 Section 3: System Parameters of OCT for SS and SD
    23:29 Section 4: Applications for both SS and SD Technologies
    44:42 Questions
  • Наука та технологія

КОМЕНТАРІ • 11

  • @yizhou866
    @yizhou866 2 роки тому +2

    Thanks for your helpful presentation! Always great!

    • @thorlabs
      @thorlabs  2 роки тому

      We’re glad it was helpful!

  • @TheSandkastenverbot
    @TheSandkastenverbot 9 місяців тому

    Thanks a lot for this very informative presentation!

  • @aatt3209
    @aatt3209 2 роки тому +1

    thank you so much for this informative & wonderful presentation.

    • @thorlabs
      @thorlabs  2 роки тому

      We’re glad you liked it!

  • @ajit_edu
    @ajit_edu 2 місяці тому

    Nice work. I was looking for this depth but simple presentation. One question - in TD OCT does the scanning of reference arm along axial direction and sample arm in lateral happen simultaneously at the same time ?
    Or we scan the reference arm to desire depth, keeping sample atr fixed, and repeat this process again?

    • @thorlabs
      @thorlabs  8 днів тому +1

      A full scan of the reference arm happens at every lateral position. This gives you the full depth information (A-scan) at an individual lateral position. You then move to the next lateral position and repeat the scan of the reference arm to obtain the next A-scan.

  • @333bctan
    @333bctan 2 роки тому +1

    will ss oct take over sd oct and why only topcon is in the ss oct technology front ?

    • @thorlabs
      @thorlabs  2 роки тому

      Thank you for your questions! We have observed a hype for SS-OCT in recent years. In our opinion, both technologies offer advantages for certain applications. SS-OCT offers great speed and power, which makes it an attractive solution for many applications today; however, SD-OCT offers the advantage of a higher axial resolution. Hence, whenever high axial resolution is crucial, SD-OCT will keep playing an important role.
      Topcon is not the only company working with SS-OCT technology; other companies are working with it too.

  • @ajit_edu
    @ajit_edu 2 місяці тому

    8.04 at SD OCT, how do get the depth information ? How k is converted to z?
    Again at 9.39 how do we get z from k doing Fourier? After Fourier we get intensity vs lambda/2pi, where is z?

    • @thorlabs
      @thorlabs  8 днів тому +1

      The Fourier transform of the interference pattern in k-space gives us the time delay between the two echoes that generated the interference pattern. Taking into account the speed of light in the medium we can calculate the path length difference between the echoes.