Point IO 1734 Allen Bradley - Input Sensor Hardware Installation Wiring Testing Programming Tutorial

Поділитися
Вставка
  • Опубліковано 6 вер 2024

КОМЕНТАРІ • 16

  • @arrond316
    @arrond316 2 роки тому +1

    Love that your covering Allen-Bradley

  • @medhanieredae2301
    @medhanieredae2301 5 років тому +1

    Thanks Vlad for uploading this amazing video. Please keep on driving the future tech

    • @SolisPLC
      @SolisPLC  5 років тому

      Thank you, I appreciate it.

  • @casualriley
    @casualriley 3 роки тому

    1:35 "without any further delays, let's get started... before we get started with today's video..." haha good one

  • @hidros1461
    @hidros1461 5 місяців тому

    Thank you for the knowledge! New sub

  • @tonydunbar6042
    @tonydunbar6042 2 роки тому

    Thank you for sharing..

  • @suriyat8773
    @suriyat8773 2 роки тому

    Thankyou

  • @samuelabreu3380
    @samuelabreu3380 2 роки тому

    Hello, I was wondering why is the reason the IO output card is blinking red? thank you

    • @SolisPLC
      @SolisPLC  2 роки тому

      Those specific modules detect that nothing is connected on the output side and blink red as a "minor fault".

  • @joew4202
    @joew4202 3 роки тому +1

    Vlad, I am having trouble adding 1794-AENT to RS linx. I am adding it in to a driver that has a Stratix 5700 which has VLANs set up on it. I have 2 PLC going into the Stratix, then I have the remote IO. I cannot get the AENT to populate in RS linx,however I can ping it. Have you ever set up AENT through a stratix? I am plugged into a switch that's connected through ethernet to the stratix. I know there's a lot going on here, I just thought maybe you could see it from a different perspective. I can make a driver with just the AENT, but when I add the stratix, it wont work.

    • @SolisPLC
      @SolisPLC  3 роки тому

      With VLANs it can be tricky; your gateways must be setup to forward the traffic correctly. I've not done it over VLANs, but I did it over a NAT configuration through a Stratix. I would definitely expect it to work the way you're describing; I'd spend more time with the settings of the Stratix; I'm not certain why the traffic isn't going through. Sorry, I can't help you further.

    • @joew4202
      @joew4202 3 роки тому

      @@SolisPLC I am thinking now I need to add the gateway for the AENT. The gateway is the IP of the Stratix. I remember now that I had to to into port configurations (on the PLCs) and set the gateway in order for the Stratix to see the PLCs. I think I will have to do the same for the AENT. So what you said did remind me that may be what's keeping the Stratix from seeing the AENT

  • @JasonStevenRyan
    @JasonStevenRyan 5 років тому

    awesome and very helpful!! any chance of some siemens?

    • @SolisPLC
      @SolisPLC  5 років тому

      Thank you for the feedback. I do have a Siemens PLC, but I wouldn't call myself an expert in it, so I stayed away from making videos on Siemens for now. I'll see if I can spend a bit more time with it in the future.

  • @florincheche163
    @florincheche163 2 роки тому

    👍👍