EIE Instruments | Marshal Stability Testing Machine | ASTM D6927, ASTM D1559 | BITUMINOUS MIX |

Поділитися
Вставка
  • Опубліковано 3 гру 2024

КОМЕНТАРІ • 39

  • @kuntalcivil7496
    @kuntalcivil7496 2 роки тому +3

    Such a wonderful presentation with all details.... Thank you very much

  • @nuwanrajapakshe5866
    @nuwanrajapakshe5866 Рік тому

    Very clear explanation .Thank you very much and wish you all the best.

  • @vedantsuryawanshi2920
    @vedantsuryawanshi2920 Рік тому

    Thank you for your valuable explanation and effective animation. It really gives a crystal clear concept reflection !!! 👍
    #KEEP UP THE GOOD WORK💐 😄🍫

  • @asifahmad5761
    @asifahmad5761 2 роки тому

    You are the best as always.

  • @biswajitmohanty1544
    @biswajitmohanty1544 2 роки тому +1

    The test is confined or Unconfined radial compressive test?

  • @shilpasarkar_l7782
    @shilpasarkar_l7782 Рік тому +2

    101 mm dia
    63.5 mm thickness ( mould dia)
    Load is applied to the perpendicular axis of a cylindrical specimen..
    50.8/ min load travel
    Test temperature - 60° c
    Per kg te koto ta load nite pache
    Compaction hammer flat circular plate weight 98.4mm
    Hammer weight 4.5 kg
    457 mm upor dia drop hobe
    51 mm dia test machine dia with 2 vertical rod
    Proving ring - measure load
    Dial gage - measure flow value
    Hot plate
    Asphalt mixture
    Constant mixer water bath
    Electronic balance
    Sample extracter
    Thermometer
    25 mm max size of course aggregate
    The mix is heated of tem 175-190
    1200 gm mix transfer in to the mould
    75 blows+ 75 blows
    Water bath time 60° for 30 min
    Load constantly travel through the specimen 50.8 mm/ min
    Test carry - height - 63.5mm
    The final marshal stability value of the sample= marshal stability value × correction factor

  • @MCU360
    @MCU360 Рік тому

    Shouldn't we keep the Marshall core for 24 hours before the Stability test?

  • @ramchandrayadav1299
    @ramchandrayadav1299 2 роки тому

    great presentation keep it up

  • @munnakumarnirala1984
    @munnakumarnirala1984 3 роки тому +1

    Good information

  • @zainullahzain5718
    @zainullahzain5718 5 років тому +1

    Very nice

  • @zeeshanAli-vx6ze
    @zeeshanAli-vx6ze 5 років тому +2

    plz make a video on triaxial compression test of soil

  • @veersinghchaudhary927
    @veersinghchaudhary927 2 роки тому

    Very right thanks sir 🙏

  • @glamhappy4066
    @glamhappy4066 4 роки тому +1

    very informative

  • @JaySingh-ul2wb
    @JaySingh-ul2wb 3 роки тому

    Stabilize wmm Ka marshal mold kaise cheak karte hai

  • @theinmin5808
    @theinmin5808 4 роки тому +2

    good

  • @abdulfattah6150
    @abdulfattah6150 4 роки тому

    Clear and narrative for easy understanding, Thanks a lot.
    Is it common that breaking assembly for modified MT comes with the machine?
    Otherwise to be purchased separately.

    • @yutitrivedi2649
      @yutitrivedi2649 4 роки тому

      Thank you for the valuable comment. MT is a a part of Marshal Stability Machine, comes along with it. Please send us your inquiry to : info@eieinstruments.com

    • @eieinstrumentspvtltd1916
      @eieinstrumentspvtltd1916  3 роки тому

      To be purchased separately

  • @kta303
    @kta303 4 роки тому +1

    nice

  • @zainullahzain5718
    @zainullahzain5718 5 років тому +1

    Great

  • @irfantalib9527
    @irfantalib9527 4 роки тому

    Thank you.

  • @afshanmunawwar1219
    @afshanmunawwar1219 4 роки тому +1

    well done thanks
    happy

  • @suryapratap5376
    @suryapratap5376 4 роки тому

    Plz explain refusal density of bitumenus mix

  • @MDMILON-tz6zg
    @MDMILON-tz6zg 3 роки тому +1

    Asphalt mix design all test motheds

  • @manasbehera6177
    @manasbehera6177 4 роки тому

    Sir Ur company supplied no. Of equipment to our govt laboratory but appt. Of Marshall stability company not provide of calibration certificate of this machine so I mail again and again but company not reply my mail ....

    • @yutitrivedi2649
      @yutitrivedi2649 4 роки тому

      Apologies for the inconvenience.....Request you to send us your calibration concern to : calibration@eieinstruments. com they will assist you.....

    • @sanjaychhaya
      @sanjaychhaya 3 роки тому

      Sir, please send your mail I'd and contact no. to send the certificates.

  • @rubelraj9663
    @rubelraj9663 3 роки тому +1

    Very nice

  • @munnakumarnirala1984
    @munnakumarnirala1984 2 роки тому

    Good information