@@FilterShopZa Thanks so much. Please don't be offended Last time i told you that i had a raw deal from puritech where i bought the eco 2000GPD machine. They dont even respond to my questions. Unfortunately i am in Zambia. Last question.: What can cause the machine to produce more water from the drainage than the purified water thats going into the final tank?
@@joshuachisanga8417 Hi, That is normal on RO if you have a higher mineral content source water. You can adjust the product water to waste water ration to improve this but you need to keep an eye on the product water mineral content as if it starts to climb then you don't have enough waste water to clean the membrane.
@@semiusefulinformation144, Here a video showing the components, you adjust the ratio with the valve on the drain side of the membrane. ua-cam.com/video/QMfhe1pvykc/v-deo.html
Hi Scott, that's not one that we have had first-hand experience with, as it's not the typical model we use. However, we are going to try source one, and if we can we will try to get a video up on its programming as well.
What happens if the tank is currently doing the work but the valvehead was accidentally detached? Last night, it happened and our brine tank was overflowing with water. Almost the whole area was full with water.
Settings lang sir ng softener,,, kailangan tagalan nyo ng 15 minutes to 20 yung time ng backwash sa softener like sa akin 3 minutes,,, 16 minutes,, 16minites at 8 minutes,,,,
That doesn't sound correct, it could be the control board or just something jamming the mechanism inside. If you're based in South Africa www.filtershop.co.za can send it in for repairs for you. I would take it off and check if you can see if there is something in the mechanism that might be interfering first.
That is very frequent, as normally you would set it to only cycle every few days. Check the drain side to see if there isn't water leaking past the seals when you hear the noise.
To manually run through the backwash cycle, you will want to unlock the valve head, by holding down the up & down buttons till there is a beep, and the key icon disappears. Then simply press the “enter” button, the second button from the left. You will hear the valve head’s motor start to turn, and a -00- code will show at first. After which a countdown clock will become visible, counting down as the valve head goes through the various cycles (backwash, and fast rinse). During all these cycles, the drain will run, and there will be no “product” water being produced by the system. You will know when the valve head has completed all the cycles, as the green bars on the left of the screen will start to flash again, the drain will stop, and the system will start to produce water from the product side.
Hi, Typically an "E1" error means that there is a fault with the pc board inside of the valve head. This can be caused by something like an electrical surge or moisture getting inside of valve head. So you will need to either replace the pc board inside the valve head or replace the valve head itself if the replacement pc board is not available.
Hi, It would depend on several different factors: What size vessel are you currently using (liters or inches)? What Media are you using (Sand, Glass Media, Birm, Carbon, etc)? What are you trying to remove from the water, dirt or chlorine, or something else? What type of source water are you using (municipal or borehole)? Have you had the turbidity levels in the water tested?
Kindly explain. The back wash outlet pipe at the back how its connected and where it leads.
Hi, The backwash would normally run to he drain or to the garden if possible. It is where the dirt that is captured by the media is released.
@@FilterShopZa
Thanks so much.
Please don't be offended
Last time i told you that i had a raw deal from puritech where i bought the eco 2000GPD machine. They dont even respond to my questions.
Unfortunately i am in Zambia.
Last question.:
What can cause the machine to produce more water from the drainage than the purified water thats going into the final tank?
@@joshuachisanga8417 Hi, That is normal on RO if you have a higher mineral content source water. You can adjust the product water to waste water ration to improve this but you need to keep an eye on the product water mineral content as if it starts to climb then you don't have enough waste water to clean the membrane.
@@semiusefulinformation144, Here a video showing the components, you adjust the ratio with the valve on the drain side of the membrane. ua-cam.com/video/QMfhe1pvykc/v-deo.html
Hi Darren.Hope you Keeping well. Could you do a demo on the F71B1 head. . Thanks . Keep up the good work
Hi Scott, that's not one that we have had first-hand experience with, as it's not the typical model we use. However, we are going to try source one, and if we can we will try to get a video up on its programming as well.
@@darrenryall1995 Thanks Darren. Hope your keeping good.
Great information sr
What happens if the tank is currently doing the work but the valvehead was accidentally detached? Last night, it happened and our brine tank was overflowing with water. Almost the whole area was full with water.
Settings lang sir ng softener,,, kailangan tagalan nyo ng 15 minutes to 20 yung time ng backwash sa softener like sa akin 3 minutes,,, 16 minutes,, 16minites at 8 minutes,,,,
Many Thanks!
If I Have 2 tanks do I program flushing at same times?
Or must they be in sequence?
Ps. Nice clip
They will have to be set to different times as while one is busy the water supply will be cut off.
Apakah alat ini bisa back was manual? Kalo bisa bagaimana caranya
can u explain the operation of dicom microcontroller based panel
Hi.. how to do backwash manual avoid the schedule. ? Thankyu
Hello there, i got a question, during installation, how am I going to manual backwash and manually fast rinse? Thanks
Watch the video 😂
THANK YOU FOR THE INFORMATION
How to fix if had error in my display : -e2- ?
What is the different with type f67c ?
how to set for the pure water flow sir
What is the meaning of F-00 and b-01 please dear guide me full method. Thanks 😊
Can you explain why my f63b1 head is not going to regeneration even if you try to force it to go just regeneration flushing but not running
That doesn't sound correct, it could be the control board or just something jamming the mechanism inside. If you're based in South Africa www.filtershop.co.za can send it in for repairs for you. I would take it off and check if you can see if there is something in the mechanism that might be interfering first.
Hey may I have your contact. Mine is +250787007922
Sir one vedio hindi me bana dijiye
Softner or filter ke wala ki setting
hi,
im trying to conntrol one of this using rs232 or rs485 is there support for this ?
Unfortunately we are not familiar with those models
Hi, I have two of these tanks with the automatic backwash system. But mine makes a noise every 30 mins for about 10 seconds. Why is that?
That is very frequent, as normally you would set it to only cycle every few days. Check the drain side to see if there isn't water leaking past the seals when you hear the noise.
Sair isko manually kaise back wash kare .
Hi, Could you maybe ask again in English then we can try and help?
what would my settings be if doing 8cubes an hour on borehole water?
Pric
Hi. Can this be setup in Google Home, eWeLink etc?
Unfortunately no
Hindi me video banavo
Sir How to do manually backwash
To manually run through the backwash cycle, you will want to unlock the valve head, by holding down the up & down buttons till there is a beep, and the key icon disappears.
Then simply press the “enter” button, the second button from the left.
You will hear the valve head’s motor start to turn, and a -00- code will show at first. After which a countdown clock will become visible, counting down as the valve head goes through the various cycles (backwash, and fast rinse).
During all these cycles, the drain will run, and there will be no “product” water being produced by the system.
You will know when the valve head has completed all the cycles, as the green bars on the left of the screen will start to flash again, the drain will stop, and the system will start to produce water from the product side.
ESpañol plis men
you would help me with that but in spanish
Hi. who here has one of this showing E1 error?
Hi,
Typically an "E1" error means that there is a fault with the pc board inside of the valve head. This can be caused by something like an electrical surge or moisture getting inside of valve head. So you will need to either replace the pc board inside the valve head or replace the valve head itself if the replacement pc board is not available.
@@darrenryall1995
Hi,
Thanks for this info. will look for possible repairs or replacement parts then.
Cheers!
By press one button automatically it will do backwash and again come to service mode...?
what would my settings be if doing 8cubes an hour on borehole water?
Hi,
It would depend on several different factors:
What size vessel are you currently using (liters or inches)?
What Media are you using (Sand, Glass Media, Birm, Carbon, etc)?
What are you trying to remove from the water, dirt or chlorine, or something else?
What type of source water are you using (municipal or borehole)?
Have you had the turbidity levels in the water tested?
Hai
what would my settings be if doing 8cubes an hour on borehole water?