HVAC-R VLOG. SUMMER TIME IS HERE !!!

Поділитися
Вставка
  • Опубліковано 6 лют 2025
  • support the channel :)
    my venmo- @hvacr_r_vlogger
    MY PATREON- www.patreon.co...
    VLOG San Francisco
    follow me on instagram @tradesmen.inc
    and @hvac_r_vlogger
    tools I carry down below
    Milwaukee battery holders
    18v battery holder - amzn.to/2RGfUl4
    12v battery - amzn.to/2S270gV
    Dewalt battery holder
    20v battery holder-amzn.to/2u7RlVc
    GAUGES AND VACUUM SETS
    -GAUGES 4 PORT-amzn.to/2tv6ZtC
    FIELDPIECE GAUGES amzn.to/30xoohr
    -GAUGES YELLOW JACKET-amzn.to/376U2od
    -VACUUM PUMP-amzn.to/3664iMf
    -MIGRON GAGUE-amzn.to/2R41mvn
    TOOLS BACGS
    -VETO BAG(TOOL BAG)-amzn.to/2NChUIK
    -VETO BACKPACK(TOOLBAG)-amzn.to/2R4vsPm
    -HUSKY TOOL BAG-amzn.to/2RumpWZ
    -HUSKY BACKPACK-amzn.to/2R3Yvm6
    -HUSKY TOOL BOX-amzn.to/2G5cNwt
    WELDING SET UP
    -TURBO TORCH-amzn.to/2R602rN
    -OXYGEN & ACETYLENE TORCHES-amzn.to/2u8awOt
    -NITROGEN PURGE MANIFOLD-amzn.to/2RwIRyG
    IMPACT DRILLS AND MORE
    -12V MILWAUKEE-amzn.to/2tm4tGc
    -18V BLOWER-amzn.to/30D9Qg7
    -18V VACUUM-amzn.to/2TAXMul
    FLASH LIGHTS
    -10V DEWALT LIGHT-amzn.to/3amMW19
    -AAA MILWAUKEE LIGHT-amzn.to/30zUMzZ
    -MILWAUKEE FLASH LIGHT-amzn.to/38oeFwn
    CAR CHARGER + FOOD WARMER
    -DEWALT 12V CAR CHARGER-amzn.to/2R6pMV5
    -FOOD WARMER-amzn.to/2NDX3ou
    PACKOUT ORGANIZERS
    -MILWAUKEE-amzn.to/2sCF0I5
    -MILWAUKEE SMALL ORGANIZERS-amzn.to/3aszmcL
    -MILWAUKEE REGULAR-amzn.to/38jgSt5
    -DEWALT ORGANIZERS-amzn.to/2Rt1zap
    -DEWALT SMALL ORGANIZER-amzn.to/2tx3m6j
    -DEWALT WALL MOUNT ORGANIZER-amzn.to/38fS456
    GLOVE HOLDER
    -MAGNETIC BOX-amzn.to/30Dcoeb
    MAP GASS AND R290 GASS HOLDERS
    -MAP GASS HOLDER-amzn.to/30wEvvw
    COPPER SWAGE TOOL
    HILMAR SWAGE TOOL/COPPER amzn.to/2tncB9o
    METERS
    -FIELDPIECE SC260-amzn.to/2FZn79v
    -FIELDPIECE SC640-amzn.to/374Zp7G
    -FIELDPIECE ST4 TEMP READER-amzn.to/368eOCS
    -FLUKE METER-amzn.to/377kvSP
    leak detectors
    -R290 LEAK DETECTOR-amzn.to/2uccfCw
    -refrigeration LEAK DETECTOR-amzn.to/30ARht5
    KNEE PAD
    -CLC KNEE PAD-amzn.to/2R5k71E
    FREON SCALE
    -REFRIGERATION SCALE-amzn.to/2TBQPcD

КОМЕНТАРІ • 68

  • @THETIMINATORTHETOOLMAN
    @THETIMINATORTHETOOLMAN 4 роки тому

    A trick to find a unit is to go by the thermostat and open your google earth and zoom in as far as you can. Then take a snap shot of the roof top unit. Then when you get in the roof you have a map!!
    I learned that trick from my co worker 😜

  • @thatfadedniqqa4639
    @thatfadedniqqa4639 4 роки тому +3

    I work at a hvac parts store and these videos help me understand more about this field and maybe one day I’ll go to school for hvac.

  • @TheOneshot78
    @TheOneshot78 4 роки тому +5

    Nice job, gave me a refresher..I need to get that poper.this how we become better techs to learn off each other. Make that money...🤑

  • @burntnturnt7222
    @burntnturnt7222 3 роки тому

    i watch your shit everyday bro just started watching im 25 just graduated hvac school and been to 6 interviews still havent gotten hired! lol but good stuff

  • @ThetalkE
    @ThetalkE 3 роки тому

    Love this videos, I am going to chattahoochee technical school this summer 2021, I missed spring enrollment.......this makes me love this job even more.......I like solving problems

  • @JJ-Toreddie
    @JJ-Toreddie 4 роки тому

    I can appreciate your attitude. I am very similar. I know many techs who could learn from you. Having a good attitude can take a person far

  • @vincentgrueter7759
    @vincentgrueter7759 4 роки тому

    An easy way to find a short quickly is to take the stat off the wall, then go back up and check continuity between all the stat wires. If you have a tone then you have a problem. Don't forget to check them all to ground as well

  • @hungryninja9185
    @hungryninja9185 4 роки тому

    Loving the vids very informative I am new to the HVAC industry I appreciate people like you who make videos like this👍🏻

  • @THETIMINATORTHETOOLMAN
    @THETIMINATORTHETOOLMAN 4 роки тому

    thanks for your video
    you explain things decently. i work in Property maintenance and we also do HVAC on commercial and residential and i am still learning. there are 4 of us and we manage a lot of properties.
    keep up the good work and stay safe.

  • @jesuss4437
    @jesuss4437 4 роки тому +8

    Ohming out the contactor coil would be something else to try when dealing with a short

  • @roastbattles3676
    @roastbattles3676 4 роки тому

    It was funny af when you made the lil guitar sound after you cracked open the red bull 🤣

  • @clentcliffordespera3892
    @clentcliffordespera3892 3 роки тому

    If the control circuit something trip off probably problem is coil contactor from blower and if the stage 1 and stage 2 demand thermostat indoor blinking you can check with multi meter coil is shorted

  • @BlueCollarBiceps
    @BlueCollarBiceps 4 роки тому

    Enjoyed this one bro! Gotta love those calls that end up being something that’s so easily overlooked, they can drive you crazy!

  • @PabloRodriguez-ck7ph
    @PabloRodriguez-ck7ph 4 роки тому +10

    Why you hate small calls?
    I work everyday calls like this.
    Im from cancun México.
    I like your videos.

  • @clentcliffordespera3892
    @clentcliffordespera3892 3 роки тому

    I love your videos bro one day i can cross USA to find a job there😊

  • @JuanTodoli
    @JuanTodoli 4 роки тому +4

    You caught the fuse filament break with the camera 🎯

  • @dylandrymond3951
    @dylandrymond3951 4 роки тому

    Next time since the Transformers easily accessible stick your little popper in between the Transformer and your jumper wire. So jump from the 24 hot side of the transformer red wire to each wire independently until something happens. If nothing happens suspect your contactor and I've even seen the ohms of resistance being too low on your Versa valve coil check both. They don't always trip the fuse instantly. The ohms on the Reversing valve coil and contactor should be around 20. I've seen the reversing valve coil down to 5 ohms and after a day or two it would trip the fuse.

  • @YuShudNoe
    @YuShudNoe 4 роки тому +2

    Anybody else hit the like button before the video starts?

  • @og6114
    @og6114 4 роки тому

    The moment you sneeze cuz you allergic to the bullshit... Salud! 😷

  • @stevensholett4821
    @stevensholett4821 4 роки тому

    Loving your channell you are killing it in the hvac world

  • @arcticarrowhvacr
    @arcticarrowhvacr 4 роки тому

    New to you're channel. Awesome work Ernesto! I look forward to following more of your adventures :)

  • @sickmike0739
    @sickmike0739 4 роки тому +2

    Alright, something good to watch while recharging from a hell of a day!!!

  • @rollandsaxton
    @rollandsaxton 4 роки тому

    I don't do alot of comercial but damn I hate those roofs always wonder if there equipment is not maintained and the area isn't so nice is the beams or wood truss gonna snap lol and then the first couple I went on i almost walked on the fiberglass area not paying attention. Be safe.

  • @gregbowman3598
    @gregbowman3598 4 роки тому

    Good video, them shorts can drive you crazy sometimes

  • @hvacknowledgechannel1621
    @hvacknowledgechannel1621 4 роки тому

    Yup temperature gonna high I made already in same issue your vlg alwys valuable big thumbs up

  • @THETIMINATORTHETOOLMAN
    @THETIMINATORTHETOOLMAN 4 роки тому

    I hate those standing seam roofs too!!

  • @Ted_E_Bear
    @Ted_E_Bear 4 роки тому +1

    Be careful of the Bat Flu !! Great job

  • @arcticmike2516
    @arcticmike2516 4 роки тому

    Hi, I’m assuming you jumpered out the smoke detector wires where they came back to the unit proving your diagnoses?

  • @richardcruz2630
    @richardcruz2630 4 роки тому

    Good video as always buddy..

  • @MotiMardi
    @MotiMardi 4 роки тому

    I had the same problem and found the contactor was the issue

  • @2Cberry2
    @2Cberry2 4 роки тому

    What app and manifold allows you to check those readings?

  • @tadz5153
    @tadz5153 4 роки тому

    what is this app and gauge that you use to check the refrigerant psi????

  • @Delacruzer
    @Delacruzer 4 роки тому

    I keep them fuses and poppers in the bag.

  • @forzamilan07
    @forzamilan07 4 роки тому

    Great vid!... Did you look out for that heat exchanger when you were drilling that hole in the supply lol I know they sit fairly close just wondering

  • @CapoGio
    @CapoGio 4 роки тому

    A guey you forgot to plug up the holes in the first call 😂😂😂👍🏽

  • @bkluntz
    @bkluntz 4 роки тому +1

    Which bag is that if you don’t mind me asking, great video as always fam

    • @joeychops
      @joeychops 4 роки тому

      bkluntz Looks like the Veto Pro Pac MC Closed Top

  • @FrostBlueFire
    @FrostBlueFire 4 роки тому +3

    Personally I would have jumped the smoke detector just to make sure the unit turns on. I've had tripped detectors, and shorted detectors mislead me for a low voltage short. For me, I have to get the unit running. If it can be done today, it'll be done today. However I don't have the balls to leave the smoke detector jumped. I'll rewire it when I leave, but I need to know if I nailed the problem lol. Good video bro

    • @FrostBlueFire
      @FrostBlueFire 4 роки тому +1

      @@Hvacrvlogger huh, makes sense, i guess they do em differently in Cali. Normally here in Florida they run the wires to the unit, some places use the unit to power the smoke detector, many bring wires to the unit, so I'm able to jump it that way. Keep up the awesome work though!

  • @richardcruz2630
    @richardcruz2630 4 роки тому

    Just started following you on IG

  • @kratosdgo
    @kratosdgo 4 роки тому

    What's bag is it?

  • @vegashvacrlife7225
    @vegashvacrlife7225 4 роки тому

    low voltage shorts are always a pain dude lol

  • @rheecesmith9653
    @rheecesmith9653 4 роки тому

    Did any one else say bless you each time he sneezed?

  • @HVACslayer
    @HVACslayer 4 роки тому +1

    You should have got the summer edition redbull man those been my go too lately 🤘🏻

  • @hrdworkin7633
    @hrdworkin7633 4 роки тому +1

    good video young man. Please stop throwing the panels around. thanks

  • @CRITITHINKS
    @CRITITHINKS 4 роки тому

    Superb vid! Watching from the United Kingdom! 😀

  • @harrydickson4575
    @harrydickson4575 4 роки тому

    Nice job 👍👍

  • @m0fr3sh90
    @m0fr3sh90 4 роки тому +2

    Just some advice, there's a high possibility for shorted relay coil, contactor coil, seized or stuck contactor causing over amp situation since it cant pull in, lastly I would jumped the smoke just to verify it that is indeed the problem and then recon8it, but yea 24 v shorts can be a pain at times. Good job nonetheless

    • @F12255
      @F12255 4 роки тому

      if those smoke terminals are shorting the fuse in the unit.the wires should be in the unit also. You could jump it there. Or it would have to be at the thermostat

    • @m0fr3sh90
      @m0fr3sh90 4 роки тому +1

      FLL 1225 exactly what I meant, didn’t want the guy to feel attacked, I’m pretty sure making these videos ain’t easy

  • @erics9213
    @erics9213 4 роки тому

    Is my assumption that the smoke detector and low voltage circuits share the same transformer? If yes, is that customary?

    • @zachbettis4006
      @zachbettis4006 4 роки тому

      Smoke detectors have a set of dry contacts that break when they detect smoke. Usually they break the low voltage on 'R' between the stat and the unit. It will most likely have a separate 120 volt circuit providing it power.

  • @rickytruong5994
    @rickytruong5994 4 роки тому +1

    Hey man love watching your videos! I'm learning a lot from them! Getting into the this trade soon so it's very exciting to watch what I could be running into. I want to get a decent hvac meter so is the fieldpiece sc260 overpriced for $230 CAD?
    Thanks!

    • @joeychops
      @joeychops 4 роки тому

      Ricky Truong shop the pawn shops. There are always meters in there for way cheaper than what they retail for. I bought my field piece 440 for $90 US at my local pawn shop. 🤙🏻

    • @forzamilan07
      @forzamilan07 4 роки тому

      @@joeychops I wouldn't trust a meter from a pawn shop but that's just my opinion to each is own. And of course if its what you can afford thats a heck of a deal. SC260 gives off weird amperage reading sometimes, 440 much better. And fluke seems to be more popular here in Ontario. More available anyways.

    • @joeychops
      @joeychops 4 роки тому

      Phollip I have a non pawn shop Fluke as well that I bust out from time to time if I feel my field piece is giving me a weird reading. But so far, in 2 years of carrying the 440 in my bag, it’s been solid and reliable. I get why some people might not trust pawn shop buys, and I respect that, but so far, everything used I’ve bought has been reliable. But than again, that’s just my personal experience. 🤙🏻

    • @rickytruong5994
      @rickytruong5994 4 роки тому

      I live here in Ontario as well! I don't think I've ever been to a pawn shop before, I didn't know they would sell those kind of electronics. Unless you can call a flea market a pawn shop, it kind of is. Thanks for the input though guys. Does the SC440 have the same features as SC260?

    • @joeychops
      @joeychops 4 роки тому

      Ricky Truong The only difference I can think of right now is Hertz and DC Amps are not available on the 260. I don’t know if you guys have a Johnstone up in Ontario, but here in Las Vegas, those 260 meters are currently on sale all month for $109 USD.

  • @pepsicolachao4537
    @pepsicolachao4537 4 роки тому

    Expect a lot of service calls from the refrigeration and AC related calls! Too bad you can't film every service calls.

  • @slickricktheruler
    @slickricktheruler 4 роки тому

    I dig it 👍🏼

  • @TheMcGuireLife
    @TheMcGuireLife 4 роки тому +1

    8:02 Sneezes Lol!!!!

  • @clentcliffordespera3892
    @clentcliffordespera3892 3 роки тому

    Coil contactor shorted

  • @vandenboschtechniek
    @vandenboschtechniek 4 роки тому

    Great video, keep m coming greetings from the Netherlands 🙏✌️

  • @raymondsvoboda4175
    @raymondsvoboda4175 4 роки тому

    Break out the meter and start ohming to ground my man. Our meters have much better eyes then we do.

  • @AngelTorres-tk2nw
    @AngelTorres-tk2nw 4 роки тому

    Super Chingon Brother.

  • @BCMoney1995
    @BCMoney1995 4 роки тому

    Any way you can message me bro ? 25 year old tech been in the game commercial and residential. Got some weird politics going want your opinion.

  • @steveblake8766
    @steveblake8766 4 роки тому

    #122 thumbs uP