  • Follow WFP Fire Alarm Engineer, George, as he embarks on a call-out to one of our customers, a London hotel, experiencing faults on their fire alarm panel.
    It's so important to keep up with your six-monthly fire alarm maintenance service visits, and acting on faults as soon as you spot them with your fire alarm (weekly testing is a great way to keep on top of this and spotting things as soon as possible). You'll see, for instance, George highlights smoke detectors which have collected dust and dirt, which can contribute to faults arising, so keeping up with your servicing to keep these clean and functional is crucial.
    To learn more about fire alarm maintenance, please click here: www.w-fp.co.uk...
    WFP is an award-winning fire, security and electrical installation and maintenance provider, based in Essex, serving businesses and commercial premises across London and the South East.
    To find out more about our services and how we keep businesses safe and legal, check out our website: www.w-fp.co.uk/
    Subscribe to our UA-cam channel for more information about fire and electrical safety, as well as security for businesses from the UK's most trusted fire and security team, WFP: / @wirefreeprotection
    And head over and like/follow us on our other social channels:
    Facebook - / wirefreeprotection
    Twitter - / wirefreepro
    LinkedIn - / wfp-fire-and-security Instagram - / wirefreeprotection

КОМЕНТАРІ • 21

  • @crazyboy2006cashier
    @crazyboy2006cashier 2 роки тому +7

    shame they didnt have an addressable system for a hotel that size.

    • @Japanese_one_Tokyo
      @Japanese_one_Tokyo Рік тому +1

      Was thinking the same thing, imagine searching for that device in that building lol
      Zone 3 fault, check zone 3 on site map (if they have one) and it’s two floors to check lol
      The hotel tried to save money installing a conventional system however it backfired when having to pay out the fire protection company more to find the fault!

    • @crazyboy2006cashier
      @crazyboy2006cashier Рік тому +1

      @@Japanese_one_Tokyo or they paid a spark to do the job not knowing any better.... until it comes to bite them

    • @Japanese_one_Tokyo
      @Japanese_one_Tokyo 11 місяців тому +2

      @@crazyboy2006cashierTrue, this can happen when you hire a electrician to do a fire engineers job.

    • @crazyboy2006cashier
      @crazyboy2006cashier 11 місяців тому

      @@Japanese_one_Tokyo wholesaler special!!

  • @simeon91
    @simeon91 4 роки тому +3

    This was actually an interesting video thumbs up from me. Don't really see much on the fire alarm systems, so more on these when you next get round to them pal.
    Keep up the good work i'm now a subscriber

  • @veritystone9861
    @veritystone9861 4 роки тому +2

    great video, really interesting! thanks for sharing

  • @Aliwff
    @Aliwff 2 місяці тому

    Amazing ❤🎉 I love it

  • @benjaminlibbeter
    @benjaminlibbeter 4 роки тому +2

    Good work 👍

  • @gregbouchard8353
    @gregbouchard8353 4 роки тому +1

    Good work mate

  • @Elliotgh2
    @Elliotgh2 8 місяців тому

    I have that pannal in my school... Cwmaman primary school... port talbot... south wales... uk

  • @battytec
    @battytec 4 роки тому +3

    Surely the dust on the detector wouldn't matter because it's a heat?

    • @wirefreeprotection
      @wirefreeprotection  4 роки тому +2

      Hi, thank you for your comment. To answer you, the detector would be compromised by a build up of contaminates (dirt) as it may prevent, or delay, the hot air from reaching the sensing element. Point detectors (smoke or heat) are passive in operation, meaning that they are fixed at a point in the building and waiting for the environment to change around them, therefore any delays to their operation could add time to detection of a fire, which ultimately compromises the fire system.

    • @battytec
      @battytec 4 роки тому +1

      @@wirefreeprotection Ah right, thank you for your reply :)

  • @yeety1208
    @yeety1208 4 роки тому +1

    Cool

  • @elliotgh2836
    @elliotgh2836 10 місяців тому

    I have that pannal in my school Cwmavon primary portalbot wales uk

  • @1987jugernaut
    @1987jugernaut 3 роки тому

    Is John butcher still working there?

    • @Japanese_one_Tokyo
      @Japanese_one_Tokyo 2 роки тому +1

      Sadly he caught covid and is no longer with us. RIP brother we miss you

    • @1987jugernaut
      @1987jugernaut 2 роки тому

      @@Japanese_one_Tokyo whatever he’s not dead I know that just wanted to know if he works there why make something like that up?

    • @Japanese_one_Tokyo
      @Japanese_one_Tokyo Рік тому

      @@1987jugernaut He’s gone bro. I’m sorry to give you the bad news.