Operating Procedure of Alfa Laval Lube Oil Purifier Onboard Ships

Поділитися
Вставка
  • Опубліковано 21 вер 2024

КОМЕНТАРІ • 16

  • @marinongmakinistangpilipin2927
    @marinongmakinistangpilipin2927  3 роки тому

    Watch ALFA LAVAL LUBE OIL PURIFIER 8,000 HOURS MAJOR OVERHAULING
    ua-cam.com/video/8pMrwZEIzCM/v-deo.html

  • @ahmetoguz5291
    @ahmetoguz5291 Рік тому

    I have seen a lot of people on UA-cam who opens the steam inlet valve to the heater before starting the purifier pump unlike you. Your way is the right way.

  • @eurasiamaritimeindustriale164

    Good Knowledgeable video of Alfa Laval Lube oil purifier

  • @makinistangmandaragattv5560
    @makinistangmandaragattv5560 2 роки тому +1

    Very informative Idol ..pa shout-out po

  • @kuyajest
    @kuyajest Рік тому

    Salamat po

  • @ciloscrisofficial1893
    @ciloscrisofficial1893 4 роки тому

    Very hi tech..

  • @atan0000
    @atan0000 Рік тому

    Paano mag adjust feed rate?

  • @archjanennunez4279
    @archjanennunez4279 4 роки тому

    💪👏

  • @vhebzdiamante7552
    @vhebzdiamante7552 4 роки тому

    Hi lods Dto napo ako sa bahay mo hug kta, pasukli nalng po,salamat God bless you...

  • @joefajardojr3902
    @joefajardojr3902 3 роки тому +1

    What does PT1 and PT4 stands for?

    • @marinongmakinistangpilipin2927
      @marinongmakinistangpilipin2927  3 роки тому +2

      Sir good day. Thank you for the wonderful question, just read it today.
      PT1 stands for Pressure Transmitter no. 1 which detects the feed lube oil pressure. While PT4 is Pressure Transmitter no. 4 which detects the clean lube oil or discharge pressure both transmitter work on the same principle they send 4 - 20 mA signal going to the purifier EPC and translate it to a digital numbers which will give us pressure reading on display.

    • @ОлегАнатольевич-щ1с
      @ОлегАнатольевич-щ1с Рік тому

      @@marinongmakinistangpilipin2927Good day sir,maybe you know that the reason, Durind Start no have PT4 -0,before its working with minimum pressure PT4 -0.9/1.0bar,but after i disamble/assemble ONLY the paring tube(Sep.Bowl not dissambled)and tray to start no more pressure present PT4=0,Give Alarm back pressure PT4-Low🤷🏻‍♂️

  • @marinongmakinistangpilipin2927
    @marinongmakinistangpilipin2927  4 роки тому

    How to read hydraulic system? Watch full video below. Thank you.
    ua-cam.com/video/MOrELEm9vdQ/v-deo.html&feature=share

  • @sandeepsaini4930
    @sandeepsaini4930 3 роки тому +1

    Sir is it ALCAP??

    • @marinongmakinistangpilipin2927
      @marinongmakinistangpilipin2927  3 роки тому +2

      Based on the manual it is an ALCaP purifier. It basically separates liquids with different densities and at same time emoves dirty micro solids from the Lube Oil.