  • HVAC hack for dummies by local plumber Mike Diack from Pipe Doctor Home Services.
    Don't miss this dramatic and insightful video!
    Pipe Doctor Home Services, Inc.
    516-348-6300
    www.pipedoc.ne...
    What’s in your Veto? Here is mine:
    Veto TP-XXL amzn.to/3zX10vg
    Milwaukee M18 Blower: amzn.to/46iTo6j
    Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
    Milwaukee PVC cutter: amzn.to/3sbrdUc
    Mini Waterproof Storage bin: amzn.to/3yfgsEv
    Wiha Allen Keys: amzn.to/33ipGmb
    HIKMICRO B20 amzn.to/33iGklx
    Furnace Switch amzn.to/31X89PT
    Milwaukee Light amzn.to/3I38Lmh
    Wagos amzn.to/34QoiaU
    Milwaukee Set amzn.to/33vnQOz
    Torpedo Level amzn.to/3no1oOk
    Crescent set amzn.to/3GtZeV8
    Wiha 7 piece set amzn.to/3rkISaK
    Milwaukee step bit amzn.to/3I395Bv
    Flare wrench amzn.to/3noJZ8s
    Ridgid 10” wrench amzn.to/3GvRnqa
    Fluke non-contact tester amzn.to/31VQgAQ
    Klein drivers amzn.to/3qoe21W
    Knipex Wrenches amzn.to/3trzFjS
    Klein 11-1 amzn.to/3tpsPLD
    12” crescent amzn.to/3A0CZ6S
    Gerber Gear Pocket Knife amzn.to/3foaW7I
    Yellow Jacket Hand Ratchet amzn.to/3nrDgup
    I am on Discord & WhatsApp!
    Discord: / discord
    WhatsApp Group: chat.whatsapp....
    Mikey Pipes Uncensored: / @mikeypipesuncensored
    Please support this channel and Mikey Pipes and consider the following…
    Pipe Doctor FlexFit Embroidered Caps
    Minimum donation of $37 is appreciated
    Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
    Sticker Requests:
    Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
    Name
    Address
    City, State, Zip
    Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
    PayPal is: office@pipedoc.net
    Venmo: @PipeDoctor
    CashApp: $mikeypipesny
    Want to send a love letter, note or gift? Our mailing address is:
    Mikey Pipes
    1010 Central Avenue
    Woodmere, NY 11598
    #hvac #PipeDoctor #MikeyPipes
    Music from #InAudio: inaudio.org/
    Track Name Fly Away

КОМЕНТАРІ • 155

  • @BurcuSevgul
    @BurcuSevgul Місяць тому +2

    Your team always goes above and beyond. Customer for life here!

  • @CLAIRBryant-w4p
    @CLAIRBryant-w4p Місяць тому +2

    Your advice on maintenance has saved me so much money over the years!

  • @atlasfueloilinc.2421
    @atlasfueloilinc.2421 Місяць тому +2

    Hey I caught the t-stat for sensor , hard one for most installers to catch. Also I didn’t see a lockbox installed over sensor, the tenants will place sensor in the refrigerator and get all the heat they want , please video any repeat calls on those thermostats , pro 8000 are the best thermostats but not always landlord friendly.
    Getting better at being an armchair mechanic. Great video

    • @carmencristantiello5176
      @carmencristantiello5176 29 днів тому +1

      or if the thermostat is in a lock box the tenant will put an ice pack to cool the sensor so the tenant is always one step ahead.

  • @MuratMehmet-v6r
    @MuratMehmet-v6r Місяць тому +1

    Watching your HVAC videos helped me fix my own AC. Thank you!

  • @SeckinHaci-l6i
    @SeckinHaci-l6i Місяць тому +1

    Flawless repair job 👌

  • @PAULAtkins-j9i
    @PAULAtkins-j9i Місяць тому +1

    Mikey Pipes, you’re not just fixing pipes; you’re fixing stress!

  • @TC_Tris
    @TC_Tris Місяць тому +2

    That's great option to have for landlords, great idea to solve his problem

  • @stephanc9288
    @stephanc9288 Місяць тому +29

    Complaining about the heat. but the 2nd floor tenant still has a window AC unit in their window lol

    • @nikosniko7092
      @nikosniko7092 Місяць тому +1

      I always see that!!!

    • @bobwhammer4237
      @bobwhammer4237 Місяць тому +6

      A friend of mine has to run their heat almost non-stop because he refuses to remove 4 very poorly installed air conditioners from the windows. When I'm over there you can feel the draft coming thru. I've offered to help remove the AC's in the off season to no avail.

    • @drewstaf2955
      @drewstaf2955 Місяць тому

      This is so common it’s not even funny. An always the tenants that don’t pay for their own fuel.

    • @Daniel.Rodrigo-05Law
      @Daniel.Rodrigo-05Law 18 днів тому

      @@drewstaf2955 actually the ones that don't pay for fuel is because it is part of the rent.

    • @Brooklynraised68
      @Brooklynraised68 6 днів тому

      If tenant pays for heat it won't be an issue

  • @johnstraley9057
    @johnstraley9057 Місяць тому

    Attention to detail does not go un-noticed while executing a well thought out plan. And educational at that!

  • @EmreFunda-c1w
    @EmreFunda-c1w Місяць тому +1

    Your fully stocked trucks are a lifesaver for emergency repairs 🚚💨

  • @DigitalIP
    @DigitalIP 13 днів тому

    I also have a Honeywell Redlink system, when i did a 2nd floor upgrade a couple years ago the system came with 2 sensors. I have it set so the sensors are used in 2 rooms for averages and the thermostat temp sensor is turned off so only the 2 sensors control it. Been extremely happy with the sensors. My only real complaint is you need a separate gateway to communicate with the thermostat, it doesnt have WIFI built in.

  • @JOHNNIEFrazer
    @JOHNNIEFrazer Місяць тому

    Pipe Doctor is redefining customer service. Always on time and prepared!

  • @Tanneritefilledfido
    @Tanneritefilledfido Місяць тому +8

    1 cycle per hour is wild. I always put at least 6 cus poorly insulated spaces need more cycles

  • @johnnyprotalk3352
    @johnnyprotalk3352 Місяць тому

    I LIKE THIS IDEA. YOUR VIDEOS ARE ALWAYS GREAT. IM A FAN

  • @pumpupjam9648
    @pumpupjam9648 12 днів тому

    Up in New York, some people have Cold climate heat pumps. They will work -10 below zero. High end heat pumps.

  • @sknight0391
    @sknight0391 Місяць тому

    Not only did I enjoy the video, I thoroughly enjoyed the video. It was like a video extravaganza!!! Good work Mikey. 😎👍

  • @spaceboy7192
    @spaceboy7192 Місяць тому +2

    Remember the accustat thermostats with the mercury bulbs you would change out for desired temperature? Simple and effective

    • @scotsmanofnewengland7713
      @scotsmanofnewengland7713 Місяць тому

      Those type had a problem with dust particles landing on the bulb there fore would weigh down the bulb and give a false setting. Learned that from an old timer.

    • @spaceboy7192
      @spaceboy7192 Місяць тому

      ​@@scotsmanofnewengland7713Your old timer must of had one hell of a dirty house. Your not even in the same ballpark. Your thinking of the T87 stat. Accustats were mostly use in commercial application and meant to be tamper proof. Google it

  • @atlasfueloilinc.2421
    @atlasfueloilinc.2421 Місяць тому

    Sensors are accessible to the tenants, most like that feature. You will be back !

  • @DIEGORitchie-h4c
    @DIEGORitchie-h4c Місяць тому

    Thank you for demystifying home repairs for us average folks!

  • @JohnDavid-u8b
    @JohnDavid-u8b Місяць тому +2

    Thermostat placement has a lot to do with comfort.
    Honeywell also has a portable remote control, with temperature sensor, allowing temperature measurement to occur wherever it is placed.
    With the remote sensor being placed higher on the wall, than the original controlling t-stat, the room temperature is now possibly cooler, while at the same setpoint, as the warm air rises and satisfies the thermostat set-point quicker, as the air higher in the room is warmer.

    • @Daniel.Rodrigo-05Law
      @Daniel.Rodrigo-05Law 18 днів тому

      They don't want the remote with the built in thermostat because they don't want the tenant to change the temp only the landlord.

    • @JohnDavid-u8b
      @JohnDavid-u8b 17 днів тому

      @Daniel.Rodrigo-05Law I know, its an east coast thing.
      But the tenant still controls the heat if they move the remote sensor.

    • @Daniel.Rodrigo-05Law
      @Daniel.Rodrigo-05Law 17 днів тому

      @ Yes but you would be able to see the energy consumption difference on the controller if I am not mistaken. the one where the new ones were installed. Yes they could move the sensor that is if they think of it but allwell the current setup the landlord will see if it works or not.

  • @FeyzaRezan-j6f
    @FeyzaRezan-j6f Місяць тому

    Quality work every time 💯

  • @JWM1800
    @JWM1800 Місяць тому +1

    I like that equipment is it app controlled as well

  • @richarddesimone960
    @richarddesimone960 18 днів тому

    Can i use the tempture probes on a regular boiler? Or just those outside central air units?

  • @RealMatthewWesthoff
    @RealMatthewWesthoff Місяць тому +3

    I’m confused, so the tenants in the first floor and second floor can’t control the temperature?
    Could you have done the Vision Pro 8000 with two interface modules?
    Enjoyed the video!

    • @jaymarking7854
      @jaymarking7854 Місяць тому

      The landloard wants to control the heat, otherwise the tenants will crank the heat up high and run up the gas bill

  • @woodystokes1543
    @woodystokes1543 Місяць тому

    Nice work man 😊

  • @fab1558
    @fab1558 Місяць тому +12

    I would have used the existing thermostat wires to connect to a wired sensor instead. No batteries.

    • @starlite528
      @starlite528 Місяць тому +2

      I think he was going for 'keep the existing thermostat so the resident is clueless that it's just a decoy'

    • @atlasfueloilinc.2421
      @atlasfueloilinc.2421 Місяць тому

      @@starlite528 correct but without a lock box , tenants will pop off the sensor and place it on the window sill outside or the refrigerator and heat as much as they want. Maybe Long Island tenants are not as internet savoy as bronx tenants.

  • @T.MacThePlumber-ny5dj
    @T.MacThePlumber-ny5dj Місяць тому

    That was awesome idea ! love it !

  • @mikehouser5430
    @mikehouser5430 Місяць тому

    Great install

  • @starlite528
    @starlite528 Місяць тому

    I guess we'll see how long it will be before they tamper with the wireless sensors. what do those thermostats do when they lose signal from the sensors? Do those thermostats have wifi or zigbee or z-wave? Is there a phone app or PC software that you can push the config to the stats without going through all those menus?

  • @dmitrynetes3102
    @dmitrynetes3102 Місяць тому

    Great work Mike!

  • @jhamm15
    @jhamm15 Місяць тому +1

    You can also install the actual 8000 tstats on each floor and set the max heat set point on the 8000’s (if you wanted tenants to have some control). You can get the internet gateway module and then control the tstats with the Honeywell app remotely so if tenants are away, etc you can turn down/off the heat/AC. There’s also the REM5000R1001, which is a cute little table remote that can toggle between the floors in case the internet goes out since it pairs directly to the tstats. I’ve never had a tenant go into the installer setup menu (you need the 4 digit code) and tamper with the max heat set point.

    • @PipeDoctor
      @PipeDoctor  Місяць тому +1

      That’s great advice, I’ll give it a try!

    • @mwolrich
      @mwolrich Місяць тому

      @@PipeDoctorif you do move the thermostats to each unit, the remote RF sensor can be put outside, and used for “anticipation” by the 8000’s, that makes it work a little quicker when there’s a sudden temperature drop

    • @eDoc2020
      @eDoc2020 26 днів тому

      Isn't the installer password just the date code? If you have access to an Internet search engine it's easy to learn this.

    • @jhamm15
      @jhamm15 26 днів тому

      @ shhhh, you ruined the secret!

  • @EvetteCochran
    @EvetteCochran Місяць тому

    Fixed it perfectly, thanks!

  • @stevencossaboon3237
    @stevencossaboon3237 Місяць тому

    Nice work Mike.

  • @mickwolf1077
    @mickwolf1077 28 днів тому

    so if the tenants want heat and use their thermostats nothing will happen until the landlord turns it on in the basement?
    what if they want half the heat.
    or is the wireless solution only serving as a maximum temperature limit?

    • @Daniel.Rodrigo-05Law
      @Daniel.Rodrigo-05Law 18 днів тому

      It is set at max 70 which aint that warm in NY winters. If they get to hot open the window a crack

  • @greekmaster1001
    @greekmaster1001 Місяць тому

    I like that solution

  • @richroj
    @richroj Місяць тому

    very good Mike 👍

  • @greghughes9736
    @greghughes9736 Місяць тому +1

    Nice

  • @josephpuchel6497
    @josephpuchel6497 Місяць тому

    Hey established what was needed and getting the job done. ✅

  • @kamechanicalhvac2891
    @kamechanicalhvac2891 Місяць тому

    Mike!!!!!! Great work brother 👍 . I would of definitely ordered the wired sensor the battery likes to play games sometimes . Installed 3 of these wireless sensors went back to that customer home 6 times already gave up and freely purchased the wire one's for the family lol . Gave up on the stupid battery games . But hopefully you don't go through that like I did 🙏🙏🙏🙏 happy New year brother many blessings for the new year

  • @johnnyprotalk3352
    @johnnyprotalk3352 Місяць тому

    JUST A QUESTION COULD YOU HAVE USED THE EXISTING TSTAT WIRES TO HARD WIRE THE SENSORS. ASKING BECAUSE SOMETIMES WIRELESS STUFF DOESNT CONNECT IN SOME SITUATIONS DEPENDING WHAT SIGNAL HAS TO TRAVEL THRU

  • @Losi5t20
    @Losi5t20 Місяць тому +2

    Just pop it off put it in the refrigerator the heat will turn on nice and toasty

  • @mwolrich
    @mwolrich Місяць тому

    I have Honeywell Redlink thermostats on my Mitsubishi Air Sourced Heat pump, 4 zones, linked to the Redlink Gateway connected to the internet.. you can adjust them remotely.. another upgrade you could suggest is setup the Redlink gateway for him, then if he’s away, he can check on the status of the 2 floors (or adjust), probably not needed in this situation, just a piece of mind bonus for the landlord, because when the tenants call, he can fire up his smartphone from anywhere, and say “I see your temperature is 72F” 😬

  • @scottmaz4063
    @scottmaz4063 Місяць тому +6

    Then the tenants puts frozen bags of peas ice cubes ect. To drop the temp. 😂😂😂

  • @DerrickCook-m6n
    @DerrickCook-m6n Місяць тому

    I have ecobee. You can read the current temp from your phone as long as you have wifi. You can also set temp. The owner could do all from his or her phone.

  • @Bigbacon
    @Bigbacon 25 днів тому

    so the tenants have no control over the temp?

  • @dimaslespier2688
    @dimaslespier2688 Місяць тому

    Mikey pipes. By disabling the alert display function. When the batteries go dead on the remote sensors the thermostat will not alert the end user.

  • @chuckq54
    @chuckq54 Місяць тому

    Sweet Mikey! 👍👍🏆🏆

  • @ryandann9362
    @ryandann9362 22 дні тому

    Couldn't the tenet just take the little wifi thermometer off the wall and put it in their fridge or outside their window to trick the unit into kicking on?

  • @themovecrew7201
    @themovecrew7201 Місяць тому

    Pretty cool, but what if they put something cool around the sensor like a bag of ice or blow a fan on it or something to fool the sensor to thinking it’s colder? If they messed around like they did previously breaking into box why wouldn’t they try something else. I like idea but there’s can always be a way around if they wanted to. Keep up the great work buddy, love the vids!

    • @throttlebottle5906
      @throttlebottle5906 Місяць тому +1

      just cover it in a damp almost dripping towel/wash cloth.....

    • @themovecrew7201
      @themovecrew7201 Місяць тому

      @ yep. I like the other comment about taking off wall n putting in fridge/freezer. Not sure this was solution. Mighta been better if like other comments to hardwire in that way a lot harder to take off

    • @throttlebottle5906
      @throttlebottle5906 Місяць тому

      @@themovecrew7201 thy could also just put it on a window sill or the floor against an exterior wall, inside kitchen cabinets that are on exterior walls. by the entrance doors/fire escapes.
      they're all many degrees cooler or outright cold. 🤣
      been in construction for many years so I know where all the cool/colder spots are lurking.

  • @jacojanks5985
    @jacojanks5985 Місяць тому +3

    Drywall anchors when mounted the sensor? When you have to replace the battery’s every year you are going to rip that thing off the wall. The you had hard wires up to the zones why not eliminate the need to replace batteries? Removing the stat And the confusion as to what is actually controlling the zone.

    • @starlite528
      @starlite528 Місяць тому

      The only confusion is for the tenant, and that is by design. They're not supposed to be changing it.

    • @jacojanks5985
      @jacojanks5985 Місяць тому

      @@starlite528 🤔 landlord must be paying the gas bill then.

  • @scotsmanofnewengland7713
    @scotsmanofnewengland7713 Місяць тому +1

    I ran into a guy who owned a 2 family two story house. What he did was when remodeling was run the hot air duct thru the wall to the second floor thru a closet wall. During the winter he would open the closet door open the vent to the ductwork and get free heat from the second floor tenant. Talk about being a cheapskate and wonder if it was illegal ?

    • @PipeDoctor
      @PipeDoctor  Місяць тому

      Well, that’s just not right.

  • @20NewJourney23
    @20NewJourney23 24 дні тому +2

    Your tenants can complain about the cold room/apartment if they buy Bluetooth thermometers and place them in the rooms. It will prove the furnace or A/C isn't working properly (to what they have it set to). You are gaslighting your tenants. It's disturbing behavior for an adult to be engaging in. If you don't want your tenants to have heating/cooling above/below a certain temperature you need to put it into the lease and explain that the thermostat is rigged in that way. People with certain health conditions need to be aware that they will not be able to be comfortable in your rentals because of your practices.

  • @michaelsannuti270
    @michaelsannuti270 Місяць тому

    I installed the same set up in an apartment building. And the tenant stole the sensor when they moved 🤦‍♂️

  • @ricktodessa3562
    @ricktodessa3562 19 днів тому +1

    If you're renting an apartment you should be allowed to set your thermostat at any temperature you desire you're renting it it's your home the landlord has no right to set your heating temperature that's b******* the landlord should be put in jail

    • @PipeDoctor
      @PipeDoctor  18 днів тому +1

      You must be a “have not”
      Have not a fucking thing positive to say in life.

  • @sunil1979dp
    @sunil1979dp Місяць тому

    Can this set up work for steam heating

  • @starlite528
    @starlite528 Місяць тому

    ah so he went with the Honeywell's :D

  • @GoogleMe-en9sg
    @GoogleMe-en9sg Місяць тому +7

    Batteries in a tenants thermostat (or sensor) is a problem waiting to happen. Either the tenant breaks the device trying to change batteries or the landlord is on vacation when the batteries go out. Best to wire in a thermostat or use a non-powered one.

  • @OnusofStrife
    @OnusofStrife Місяць тому

    Didn't they have poor flow or something to the second floor?

  • @TheMrBrandonlewis
    @TheMrBrandonlewis Місяць тому +1

    So, now the tenants can’t control temperature at all?

    • @GOPRepubliklan
      @GOPRepubliklan Місяць тому

      YEP! JUST THE WAY IT SHOULD BE

    • @TheMrBrandonlewis
      @TheMrBrandonlewis Місяць тому

      @ lol good thing its wireless! just wait till they stick that thing in the refrigerator!

    • @throttlebottle5906
      @throttlebottle5906 Місяць тому +1

      sure they can, call/text and knock on the the landlords door at all hours. 🤪

  • @jackl9922
    @jackl9922 Місяць тому +13

    I’ve fooled those before - a baggie of ice.

  • @MikeSeris
    @MikeSeris Місяць тому

    I replaced the pressuretrol now the heater shuts off randomly and I have to hit the reset button on the pressuretrol for it to run again. It won’t ignite unless I hit the reset button on the Honeywell L4079B1033. Any help will be greatly appreciated

    • @throttlebottle5906
      @throttlebottle5906 Місяць тому

      you do realize that's a high limit safety cutoff control right? it's not meant to cycle a boiler on/off maintaining pressure and will always need manual reset if it opens.
      if that's the case, you need a professional and to not be tinkering with a steam boiler, before you possibly harm yourself or someone. not meaning to be harsh sounding, but steam is nothing to play around with.

  • @snownek-6236
    @snownek-6236 Місяць тому

    that one heat call per hours may not be a good selection. my house dose about 4 per hour but its not insulated well and it below zero most all winter.

    • @PipeDoctor
      @PipeDoctor  Місяць тому

      You're right, that was just for demonstration purposes.

  • @mobettaspice
    @mobettaspice Місяць тому +1

    I think it would of been best if they didn’t know where the new temperature sensor was located. Now it could be tampered with.

  • @chrishorne2740
    @chrishorne2740 24 дні тому

    And you hope the 2nd floor doesn't toss it into the refrigerator in the mornings...

  • @CaptainW1nky
    @CaptainW1nky 26 днів тому +1

    70 is cold for winter lol, glad I don't rent... I wouldn't pay

    • @20NewJourney23
      @20NewJourney23 24 дні тому

      I agree. It depends on the person whether 70 is fine or if it's too cold. Some people have health conditions which can cause problems for the temperature to be at or near 70 degrees in the winter 70 degrees is the minimum temperature I can handle but I normally have my thermostat set to 75 year round. That five degrees really makes a difference in keeping my hands and feet safely temperature controlled. I have Raynaud's Phenomenon which is a blood flow problem caused by autonomic nervous system dysfunction. My central nervous system tricks my feet and hands into shrinking the blood vessels and preventing proper blood flow when the temperature is near 70 degrees (or lower). My hands and feet turn white or blue depending on how bad the blood flow is restricted. The only protection I have for my feet and hands is warming them up to 75+ degrees. People have lost their hands or feet in non-freezing temperatures because of this health problem. I haven't (yet) but I've been able to control the temperature of my home on my own.

  • @jerrylockhart3069
    @jerrylockhart3069 Місяць тому

    Which one of those has priority neither?😅

  • @jaymarking7854
    @jaymarking7854 Місяць тому +3

    I see you did Cycle per hour(CPH) at 1 on the first floor, and 3CPH on the 2nd. Guess you didn't read the manual?? 1 is for steam heat, 2 is for hot water heat, and 3 HE forcced air and 5 for old forced air. . I can see you getting a call back on 1CPH!

  • @BoilerMaker56
    @BoilerMaker56 Місяць тому

    I put a lot of these vision pros in. I absolutely love them. Funny thing is Honeywell told me that I shouldn’t put the Vision Pro thermostats any closer than 6 feet away from each other. I did them anyway and never had an issue. They say the sensor sometimes get confused. I’m not sure if this is an issue that’s been corrected, but I love the way they work. Good job on that Mike.

    • @PipeDoctor
      @PipeDoctor  Місяць тому

      That’s interesting, I’ve never heard that one before.

    • @starlite528
      @starlite528 Місяць тому

      I wouldn't be surprised if they didn't understand and thought you wanted to put the sensor right next to the thermostat.

  • @craig1611
    @craig1611 Місяць тому

    Should have used wired sensors. Batteries suck

  • @RobertDeFreitas-q5r
    @RobertDeFreitas-q5r Місяць тому +1

    you set the thermostat to use its internal temp sensor. you do realize that dont you?

  • @throttlebottle5906
    @throttlebottle5906 Місяць тому +1

    woah, 1 cycle per hour is far too low, for a drafty old place. it will end up yo-yo swinging and them still complaining, which they likely will anyway, not being able to set it at what they feel comfortable.

  • @Vigilante-k4q
    @Vigilante-k4q 23 дні тому

    You sound like Tony soprano

  • @tedlahm5740
    @tedlahm5740 Місяць тому

    and who will change the battery EACH YEAR on the tenant floors?
    Knowing, it will not be done.

  • @ChrisTopher284765490
    @ChrisTopher284765490 Місяць тому

    Done Deal on that one. Happy New Year Mike !

    • @atlasfueloilinc.2421
      @atlasfueloilinc.2421 Місяць тому

      Sensors are accessible to the tenant, most tenants like that feature

  • @nickc6399
    @nickc6399 Місяць тому +13

    One cycle per hour? That’s going to be an issue

    • @MoonRambo702
      @MoonRambo702 Місяць тому +4

      That’s what I came to comment.
      Callback in the making. Tenant gonna find out the other floor got 3😂

    • @tekjunkie28
      @tekjunkie28 Місяць тому +1

      I just max cycles for everything. Is there any situations where you want less cycles for heating?

    • @nickc6399
      @nickc6399 Місяць тому +1

      Over sized equipment

  • @sircampbell1249
    @sircampbell1249 Місяць тому +1

    Should have 3 zones..... one for each floor

    • @TheReduxGB
      @TheReduxGB Місяць тому

      He did say he would be back to make the basement a third zone

  • @bills6946
    @bills6946 Місяць тому +1

    Did you set thermostat sensor to control yes? Should be NO. THE REMOTE WILL CONTROL THE TEMPERATURE. Cycles per hour 1 Should be 3 or 5.

  • @fab1558
    @fab1558 Місяць тому

    Mike, give me the credit. I told you on the last video the 8000 comes wifi. 😅

    • @greekmaster1001
      @greekmaster1001 Місяць тому

      You win a banana

    • @spaceboy7192
      @spaceboy7192 Місяць тому

      OK...should have told him to use the original thermostat wire and install a wired sensor. Won't have to mess around with dead batteries...😮

  • @signal12hvac
    @signal12hvac Місяць тому +1

    you set tstat to read temps never mind you caught it

  • @joshuabest100
    @joshuabest100 Місяць тому

    You should have put the sensor in a lock box the tenant just gunna put the sensor outside and have infinite heat

  • @speedy4829
    @speedy4829 Місяць тому +1

    Why leave the thermostats in the apartment? Just going to create more drama…cranking and playing with them while not hitting any crazy set points used above 70. Should have just eliminated the apt thermostats, recycle the existing wire to use direct wire sensors vs batteries and tell the tenants to suck it. Most restrictive laws require 68….LL is providing 70.

  • @peter-pg5yc
    @peter-pg5yc Місяць тому +9

    why rent when scumbag landlord prevents you from heating comfort Cheap arse landlord needs seperate meters and systems for the renters. if not renters go some where else. with rents like they are we demand control not scummy landlords. Plus landlords set up a proper rental with seperate meters etc, easy done. This will surly piss off tennants..

    • @bobshanery5152
      @bobshanery5152 Місяць тому +1

      Rent is up due to Government and monopolies who control said government. People seem to ignore this.

    • @bobwhammer4237
      @bobwhammer4237 Місяць тому +1

      Landlords rent out space to make money; they're not a public service to provide you with comfort so that u can walk around in your undies in the winter. We all know that when heat and electric is included, renters abuse it. Get your own damn house and run the thermostat to 75 in the winter. Let us know what your heating bills are. Maybe you're expecting the "gov" to help u?

    • @JimmydaGooch
      @JimmydaGooch Місяць тому +4

      ​@@bobwhammer4237 They only will run the thermostat that high when they ain't paying the bill lol

    • @SlayerDork
      @SlayerDork Місяць тому

      @@bobshanery5152 Don't forget the property tax cost that the landlords just pass on to the tenants.

    • @nxsecuresucks
      @nxsecuresucks Місяць тому

      this is why renters want out of renting.. but can't buy a house do to the scam house market. Houses DO NOT INCREASE IN VALUE! this is a scam.
      regardless... the tenants should have full control over their own heat but yes at their cost when possible.. I could soooo easily see a tenant putting this in a fridge or by a window to trick the system into heating. hahahahaha.

  • @kens.3729
    @kens.3729 Місяць тому +1

    Probably a Tenant who likes it Hot Indoors and Opens Windows to get Comfortable. 🤪👎

  • @tedlahm5740
    @tedlahm5740 Місяць тому

    “Let’s take this outside.”. please

  • @jerrylockhart3069
    @jerrylockhart3069 Місяць тому

    There in the hallways? Are there any heat in the hallways since normally the perimeter of the house is on the hydraulic water feed loop unless the hallways are on the edge?😅❤🤔😎

  • @patram4880
    @patram4880 Місяць тому +2

    Too complicated you can keep it

    • @PipeDoctor
      @PipeDoctor  Місяць тому

      Easy

    • @throttlebottle5906
      @throttlebottle5906 Місяць тому

      I have removed more of that junk, than I have ever installed. over complicated, failures, they tend to randomly reset, lose sensor connectivity(RF noisy environments) which is pretty much every home and device people use now.

  • @charlespipitone2324
    @charlespipitone2324 Місяць тому

    Now, if you understood how system 2000 worked as good as these Honeywell,
    You will agree how good the system 2000 systems are.
    Lmmfao

  • @JAYJAYJAY53
    @JAYJAYJAY53 Місяць тому

    Get new tenants

  • @lonewolf1401
    @lonewolf1401 23 дні тому

    landlord could use that for nefarious reasons also... slumlords

  • @TheRAMBO9191
    @TheRAMBO9191 Місяць тому

    🥃👍🏻

  • @steveblake8766
    @steveblake8766 Місяць тому

    508th thumbs up

  • @fred-qy4lo
    @fred-qy4lo Місяць тому

    Nice.😀

  • @PlymouthVT
    @PlymouthVT Місяць тому

    Should have brought the thermostat wire sheath all the way under that plate instead you got a butch'ed up sheath before it enters the base of the plate. Looks like you could have drilled a hole and brought it in from behind the plate. And they make better staples than those big ugly ones you use.

  • @t.a.servicehvact.a.service3189
    @t.a.servicehvact.a.service3189 Місяць тому

    heating fašizmus

  • @charlespipitone2324
    @charlespipitone2324 Місяць тому

    Now, if you understood how system 2000 worked as good as these Honeywell,
    You will agree how good the system 2000 systems are.
    Lmmfao