Fixing Onan 5500 Marquis Generator. It shuts off when start button is released

Поділитися
Вставка
  • Опубліковано 2 тра 2024
  • In this video I replace the brush block on my RV generator. I thought I was going to have to replace the entire control board but it ended up just being the brush block which saved me over $600!
    The generator would start but shut off as soon as I released the start button. It was giving me fault code 37 which is Invalid Set Configuration. The Cummins service manager recommended I start with this $50 part instead of the $680 control board. If this video helps you please do me a favor and subscribe. It would mean the world to me as I am trying to grow my channel.

КОМЕНТАРІ • 10

  • @thomasheaney2087
    @thomasheaney2087 День тому

    Thanks

  • @RyanColeman-e2t
    @RyanColeman-e2t 10 днів тому

    Thank you for this! Great video. I have the same issue. I've replaced just about everything else. I'm going to give it a shot!

  • @GaryLawson-b4j
    @GaryLawson-b4j 14 днів тому

    This was great change brush block and it did the trick THANKS

  • @CharlesGraham-ll2in
    @CharlesGraham-ll2in 2 місяці тому

    YOUR VIDEO SAVED ME FROM BUYING A NEW GEN!!! I have called Cummins…no luck, other mechanics…no luck, BUT this video did it! I however used a paint stick with a piece of a scotch brite pad taped to it to clean the rings. Worked perfectly. Installed new brush box, said a prayer and hit the start button. She purrs like a kitten!!!

    • @realgratitudejourney
      @realgratitudejourney  Місяць тому

      That is so awesome to hear!! Thank you for sharing, it really made my night!

  • @melanieclark-hubbard2219
    @melanieclark-hubbard2219 2 місяці тому +1

    Great info

  • @MPuch9
    @MPuch9 3 місяці тому

    Love the video!

  • @asellers62
    @asellers62 2 місяці тому +1

    The wrench does IN FACT NOT* fit nicely in between there.