MasahAllah,, Allah aap ko or vi knowledge barha de,, aap ki es video ke zariye mai apna ek same inverter ki same problem solve kiya hai.... Mujhe bahat Khushi hoyee aap ki es helpful troubling video jo mujhe mila,, Thank You very much, vaijan.....
Sir ap ka andaza teek hoga hamary 3 inveter johe kharab he sab ka mosfet kharab he wo nambar nahe mil raha he ek 1500w ka he or 2 220w ki he sab ki ek sardi hi
jazak Allah bhai bohat achee detail videos hain ap ki inverter pe may nay nia inverter lia hay 1000 aur 1500 wtts k theek chalte hain 10 volts hab battery k reh jate hain to cutoff bhe hote hain per jab load of hota hay aur batteri k volts dobara 12 .5 per a jate hain to ye khud he on ho jata hay jab k is ko off rehna chahye isko manual of karna per ta hay warna ye on of karta rehta hayis ka kia hal hay bhai '
Sir apky samjhane ka treqa bht acha ha, plz aik derailed video mobile charger circuit repair k bare main bnaen, plz ye b bta den k CFL ko kese repair karen gay aur CFL ki output kesy check ki ja sakti ha.
bhai mere pass inverter 1000 watt ka uski red light on of ho rahe hai . dc section ka ak transister bhut heat ho raha hai plz kuuch bataien mehrbani hogi jazakallah
bhi 500 watt inverter beep sound day raha aur output voltage nhi a rahy sari mosfet bee theek hain check kee hain jab open kya tha too button khrab tha aur fan jaam tha kya msala ho sakta ha plzzz batanay
Namaskaar bhai saheb. Me ek bath poochna chaathahe. Mere paas 1000w ka inverter hai. Usme dc 12v supply laganeke bath ac 220v nikalthaye. Lekin 15, 20 minutes ke bath banth ho jathahe. Pher dhubara inverter ka switch off karake on karanake bath chalu ho jathahe. Paerbi 15, 20 minutes ke bath banth hothahe. Jab inverter chalu karthahe uska cooling fan chalu hoke 5 secondme banth hothahe. Iska fault kyahe mereko batha shakthaye tho me apko bohoth, bohoth sukiriyaa karthahun.
2000w ka inverter hi Jo AC output nahi deraha tha or red+green light on ho Rahi thi too ak mostwiar 47N60CFD karab tha wo change Kya 20N50C too 2 Ganti PC challya or kod turn off kya thake Kam fir jab sham ko on Kiya too wahi masila aarah hi chake kya too 20N50C b karab ho giya hi PLZZ selushan
Sir plzz plzz thora sa infom kar dyn Me abi abi new ly k aya ho ghr aa k chlya ha to 1 mint k liye green light on hoi bad me red light on ho gye or invert km b nahe kar raha red light chlti ha or awaz ati ha bas plz plz sir gide kry kia kro Me wt kro ga sir apky reply ka
Bhai jan mera inveter on ho raha hai gree light chal rahe hai lod dalte he red light on ho jati hai mostfet sahe hai magar capiaiter per sparking kar raha hu waha koi rispons nhe ata kya capiaiter kharab ho sakta hai
bhai meter ki red or black pin ko transistor ki first two legs pe lgao agr first leg pe red pin lge or meter reading de to pnp hy or agr first leg pe black wali pin lge or reading aey to npn hy
green light on ho rhi hai lekin fan nhi chal rha or out put b nhi aa rhi agr battery voltage 8v ya 9v hon tu fan on ho jaye ga lekin red light on rhe gi ye fault aa rha hai tamam mosfet or fuse check kr lie theek hein
Sir mery pas 1000 watt ka inverter hy is jesa wo foult red light deta hy or output ni deta kibi kabar theek chalta hy or aksar kharab rehta hy kiya waja ho sakti hy
@@theexpertssolar ap ki video dekhny k bad main ny usy khol k chek kiya to 2 fit khrab ty 18n50 waly lagy thy usy replace kiya to red light wala masla to hal ho gya magar output sir 20v hy kiya waja ho sakti hy
Bhai mere inverter me b 2 mosfet kharab he.. ac wale side ka .. aik MAR627 he aur dosra CHN920 he.. lakin me bhol gaya konsa mosfet kidr se khola.. aur dosri bat ye he k ye same kiu nhi he. aik side pe tho sare same nhi aty kia. plz thora detail se muje samjaye ap... aur ye b bataye is ki jaga koi aur laga sakta hun plzz. apke comnt ka intezar rahega bhai
Acha agar me sare old nikal k sare aik jese irf 740 lagadun tho teek rahega ya nhi... aur muje sab se best mosfit batado agar Irf740 se he tho whi laga lunga bhai... ham ko time dene k lie shukriya❤️
mere pas jo problem hai wo ye hai k green light on ho rhi hai lekin No output fan off hai lekin jab battery volt 9v krdein tu red light onnho jati hai ot fan b chal jata hai jabke mosfet koi b bkhrab nhi hai
Ek Chota sa masla hai App k agar samaj mein araha hai tho Guide kijea ga En Inverters se Laptop ka Charger malfunction kio karta hai. Jab bi laptop ka Charger connect karta hon tho laptop ka USB port kam karna band kar deta hai Mouse bi kam nahe karta Any Solution
Matlab Mein Inverter k Output pa ek Fan Capacitor 2.5uf Parallel Connect Kardon, tho ya Square Wave to Sinusoidal Wave mein Convert kar de ga, Thanks Buddy
Me aaj hi ye le kar aaya hun aur ye ghar aate hi check kia to fault light jal rahi thi output 220 nahi araha tha kholker dekha to thori dair 220v aaye red light band hui per kuch seconds bad start hogae red light
سر ۔اگر کوئ ٹرانزسٹر نہ مل رہا ہو تو کیا اس کے جگہ دوسرا نمبر کا ٹرانزسٹر استعمال کرسکتے ہیں۔ مثلاً چار ٹرانزسٹر 3205 کے لگے ہیں ان میں سے ایک جل گیا اس ایک کی جگہ دوسرا نمبر 4145 لگا سکتے ہیں۔ رہنمائی فرمائیں
بھائی میرے پاس soure sta1000 inverter ہے اس کی كلمپ الٹ لگ گئے تھے اب وہ شارٹ ہو گیا ہے میں اس کی تمام mosfit ڈی سی والی Hy3506 نکال کر irf 1906 لگا دی ہیں لیکن ابھی بھی شارٹ ہے
MasahAllah,, Allah aap ko or vi knowledge barha de,, aap ki es video ke zariye mai apna ek same inverter ki same problem solve kiya hai.... Mujhe bahat Khushi hoyee aap ki es helpful troubling video jo mujhe mila,, Thank You very much, vaijan.....
Hi sir ap ka channel super ha. Mara chennal b repairing par ha. Or earning kar raha ha
Aap ki videos boht achi hen... Keep it up....
Sir mosfet k4145 nahi mlraha he to kon sa mosfet ues kary jaldi me vidio banao
Sir maira 12 v charger K 7 jab universal module lagata ho to geen led K 7 Red led on krta hai.
Sir ap ka andaza teek hoga hamary 3 inveter johe kharab he sab ka mosfet kharab he wo nambar nahe mil raha he ek 1500w ka he or 2 220w ki he sab ki ek sardi hi
Sir plzzz 12v to 220 2000w ki repairing ki full detail wali video bnao , hamian ap ki video ka intzar rhy ga
Click the link for more and dont forget to subscribeua-cam.com/video/mmN4AmhLBW8/v-deo.html
jazak Allah bhai bohat achee detail videos hain ap ki inverter pe may nay nia inverter lia hay 1000 aur 1500 wtts k theek chalte hain 10 volts hab battery k reh jate hain to cutoff bhe hote hain per jab load of hota hay aur batteri k volts dobara 12 .5 per a jate hain to ye khud he on ho jata hay jab k is ko off rehna chahye isko manual of karna per ta hay warna ye on of karta rehta hayis ka kia hal hay bhai '
sir 1906 transistor ke jagha koi our transistor laga sakte hai batado thnks
Sir apky samjhane ka treqa bht acha ha, plz aik derailed video mobile charger circuit repair k bare main bnaen, plz ye b bta den k CFL ko kese repair karen gay aur CFL ki output kesy check ki ja sakti ha.
Sir ap ka kai hal ha mar pass 2000 w ka inv as dc side wal 047n08 mosfit kharb as no ka mak ma nhi mal ra khoi dors no bata dan
Brother in k circuit diagram chahiye hon to wo kesy milen gy ? Q k baz oqaat resister diod or transistors blast ho jaty hen phir on k number ni milty,
sir TL494 ic jo ac side p hoti he unko vcc line kahan se milti he,
pin no.12 pe volt nahi aa rahe
Great video. Bhai mery 1000 watt k inverter ka ic jal gya hy ic ka code hy (ka 7500B) . Kya ic repair ya replace ho sakta hy? Please answer kr dain
G achi electronics shop se mil jai ga
@@theexpertssolar thank you very very much bhai. Meny Aliexpress sy 10pc order kr diya hain ic k.
Bhai is inverter ups ki single wire per phase de kr Chala skty hyn?
bhai mere pass inverter 1000 watt ka uski red light on of ho rahe hai . dc section ka ak transister bhut heat ho raha hai plz kuuch bataien mehrbani hogi jazakallah
Meet Bhai ham ny AC side ka transistor 740 kharab that wo ham ny change Kiya h start to ho raha h AC side K Bech M sy chingari Dy raha h fault Kia h
1000 watt conwter ac one sed out 220 hota hi is kya masla ho ga
AOA
Bahi Kia DC wali side par 6 mosefit laga saktay Hain jahan 4 lagay howay hain
Sir inv ka mosfet check krna btaen k kis taang pr value dega or kispr nh
Bhai jan jo mosfit ka sath resister hota ha. Us ka number ha. 823.ye na mila to is ki jaga kon si lagy
sir mere inverter main 110 volt output ho rahe Hain mene 4 output mosfet change kar die phir bhi volt drop Hain kindly iska btaen plz
Bhi jan mara 500watt h wo buzzer sound dy raha aur red light bee blinking karti kabi kabi kya masla h?
Nhi output voltage nhi a rahy
bhi 500 watt inverter beep sound day raha aur output voltage nhi a rahy sari mosfet bee theek hain check kee hain jab open kya tha too button khrab tha aur fan jaam tha kya msala ho sakta ha plzzz batanay
Apna WhatsApp number dy plzz
Click the link for more and dont forget to subscribeua-cam.com/video/mmN4AmhLBW8/v-deo.html
Bhai inverter sockt output py tester glow krta 2no mn
Sir mere 3 chopar 2000w Wala inverter ha uske har components ok hen green light fan sub kuch chal rhi ha lekin output volt nhe arhe uski koi solution?
Output voltage 116 a rhy hyn plz uska kya treeqa h theek krny ka
Bai Jan inverter Mai ek cuta variable resistance laga ota hai o Kiya Kam karta hai
Konsi jaga par❤
Bhai help plz, mere pas single ic wala inverter ha os ki ic kharab ho gai ha ic per number ni likha hua, plz ic ka number bta den plz plz plz
Aoa sir kiya irf 740 ki jaga koi or mosfit laga sakty hain matlab ky agar same number ka mosfit na ho or koi or para ho jessy 3205 ya koi or
Sar g invartar hy wo aut put dety hy lekin lod bar dash nahy kart on off karty hy
agr invertor ki red light on hi rahy to kia fault ho sakhta ha? tell about it !
Namaskaar bhai saheb. Me ek bath poochna chaathahe. Mere paas 1000w ka inverter hai. Usme dc 12v supply laganeke bath ac 220v nikalthaye. Lekin 15, 20 minutes ke bath banth ho jathahe. Pher dhubara inverter ka switch off karake on karanake bath chalu ho jathahe. Paerbi 15, 20 minutes ke bath banth hothahe. Jab inverter chalu karthahe uska cooling fan chalu hoke 5 secondme banth hothahe. Iska fault kyahe mereko batha shakthaye tho me apko bohoth, bohoth sukiriyaa karthahun.
Sir ma na yehe inverter lgaya ha wo just 95 volt da rha ha output ma hala k output 220 dani chaye kia masla hoga
MA Sha Allah vvv nice sir
Bhai red light on.hu rahi hai per current output nahi hai .
Kya problem hu sakti.hai
1000 watt inverter bajar ke connection ki video pehnao
2000w ka inverter hi Jo AC output nahi deraha tha or red+green light on ho Rahi thi too ak mostwiar 47N60CFD karab tha wo change Kya 20N50C too 2 Ganti PC challya or kod turn off kya thake Kam fir jab sham ko on Kiya too wahi masila aarah hi chake kya too 20N50C b karab ho giya hi PLZZ selushan
8:48
Mosfet k pas zener hi ,Kya Voltage,value k hi?
Mere pass invorex ka analog 1000va hay vo had 10 mint me bad band ho jata hay backup par kia fault ho Santa hay sir
Sir mara inverter on b sahi hota ha red light b nhi on hoti output nhi dyta
great video
aoa sir mara 1000w ka inverter ha output cut cut kr aa rahi ha kia waja ha
Sar dono side elada hoty han dono side k jal jaen to kon kon sa lagen ak side 4 lgy han or ak side 6
@@theexpertssolar us. Mn b ni yaad sar purana khraab h or us par ab koi ni lga hoa
Bro ais ki total output Kitnay watt hain
Bhai Mera invetar chota hai aski input mosphet dono Phil garam hota hai aor ye Nahin chal Raha Kia fault hoga
Bazar ke connection per video banao
Sir apki lab kidar ha i want repair inverter
500 watt inter chal raha hai leken out put nahi de raha bhai iska kia hal hai
Sir DC side ke bhe video banao
kia aap lahore se hain. mere paas aise 2 inverter 1000w repair karwane hain. kahan se repair karwaon
Sir plzz plzz thora sa infom kar dyn Me abi abi new ly k aya ho ghr aa k chlya ha to 1 mint k liye green light on hoi bad me red light on ho gye or invert km b nahe kar raha red light chlti ha or awaz ati ha bas plz plz sir gide kry kia kro
Me wt kro ga sir apky reply ka
Bhai jan mera inveter on ho raha hai gree light chal rahe hai lod dalte he red light on ho jati hai mostfet sahe hai magar capiaiter per sparking kar raha hu waha koi rispons nhe ata kya capiaiter kharab ho sakta hai
Bhai mene ab mosfet chang keye .ab red light or green light chal rahe hai or line bhe nhe a rahe palag main
Sir plz mera ek sawal hai k agr smd transistor kharab ho jae circuit me to os ka pata kaise lage ga k wo npn hai ya pnp
Sir ye hr smd transistor k opr leka howa hota hai
bhai meter ki red or black pin ko transistor ki first two legs pe lgao agr first leg pe red pin lge or meter reading de to pnp hy or agr first leg pe black wali pin lge or reading aey to npn hy
Bar bar tahi issu arha hye,, kia waja hogi
irf kon sa acah he plz tel.me mere invertor ka irf kharab ho jat he
Mere inverter men same volt hain 154 55 tak MOSFET ok hai sab check kiye hain lekin masla solve nhi ho raha
Mujhe Electric ka kam seekna ha koi seka dy ga please
Thank you sir
green light on ho rhi hai lekin fan nhi chal rha or out put b nhi aa rhi agr battery voltage 8v ya 9v hon tu fan on ho jaye ga lekin red light on rhe gi ye fault aa rha hai tamam mosfet or fuse check kr lie theek hein
اسلام علیکم بھائ 1000واٹ اور1500 واٹ انوائٹر میں A cسائیڈ کونسے کونسے موسپیڈ لگائے جاتاہے زارا بتائی شکر یہ
Thankfully sir g
Sir mery pas 1000 watt ka inverter hy is jesa wo foult red light deta hy or output ni deta kibi kabar theek chalta hy or aksar kharab rehta hy kiya waja ho sakti hy
@@theexpertssolar wire to orignal hy jo sath i thi or grip b theek hy albata button chaing kar leta hon
@@theexpertssolar or ap ko bohot bohot shukria jo rehnumai kar di ap ny
@@theexpertssolar ap ki video dekhny k bad main ny usy khol k chek kiya to 2 fit khrab ty 18n50 waly lagy thy usy replace kiya to red light wala masla to hal ho gya magar output sir 20v hy kiya waja ho sakti hy
Bhai hamary ups ki toono lights nahi on horai
mere pas Sooer copmny ka 1500 watts ka inverter hy kuch din se Voltage kum de raha hy
Very nice bhai
100w inver chal raha ha green light on hoti he jab tv cjalate hen to tv on off hoti he kya problum hosakti he
100 watt pe sirf mobile charge kr lia kro ... iss se oper nai
Bhai mere inverter me b 2 mosfet kharab he.. ac wale side ka .. aik MAR627 he aur dosra CHN920 he.. lakin me bhol gaya konsa mosfet kidr se khola.. aur dosri bat ye he k ye same kiu nhi he. aik side pe tho sare same nhi aty kia. plz thora detail se muje samjaye ap... aur ye b bataye is ki jaga koi aur laga sakta hun plzz. apke comnt ka intezar rahega bhai
Acha agar me sare old nikal k sare aik jese irf 740 lagadun tho teek rahega ya nhi... aur muje sab se best mosfit batado agar Irf740 se he tho whi laga lunga bhai... ham ko time dene k lie shukriya❤️
ye IRF740 ac wale side pe hi ate hena bhai
@@theexpertssolar old wale sare nikal k irf740 lagadun? g bhai?
Bhai apka whatsapp nmbr mil sakta he plz
Mara irada hay Kay may solar max yea nitrox ka 5kv inverter laga Lo agar ye harab hotay hay to may na Laglo yea laga lo ap ke rayea chayea
@@theexpertssolar thanks
is invertor ko as a ups kasay use karay
@@theexpertssolar thanks bro....
sir....stabizer k ander jo theen moo ka soket chal gayah ha...us ko lagana k kia tarika ha
mere pas jo problem hai wo ye hai k green light on ho rhi hai lekin No output fan off hai lekin jab battery volt 9v krdein tu red light onnho jati hai ot fan b chal jata hai jabke mosfet koi b bkhrab nhi hai
Bro ye multimeter kitne ka or kaha milega
Great
In Sinevay inverter how to take out Double print
Ek Chota sa masla hai
App k agar samaj mein araha hai tho Guide kijea ga
En Inverters se Laptop ka Charger malfunction kio karta hai.
Jab bi laptop ka Charger connect karta hon tho laptop ka USB port kam karna band kar deta hai
Mouse bi kam nahe karta
Any Solution
@@theexpertssolar 2.5uf
220v AC ???
Thanks for reply
Matlab Mein Inverter k Output pa ek Fan Capacitor 2.5uf Parallel Connect Kardon, tho ya Square Wave to Sinusoidal Wave mein Convert kar de ga,
Thanks Buddy
@@theexpertssolar Thank youuuu
yar mera inveter hai jo 440 de raha hy kia falt ho ga .plz reply.
@@theexpertssolar variable chang ki vohi masla hy
@@theexpertssolar konsa capistor koi hint please resolve my problem meri shop hy.
sir aap k tamam inverter mein mosfet he khrab hota hai is k elawa koi or faulty nhi hota
Great bro ❤️❤️
Red or green dono on hu rahi hain.lekin current nahi aa raha hai
thanks vaiya 😘😘
Great 👌 g
Me aaj hi ye le kar aaya hun aur ye ghar aate hi check kia to fault light jal rahi thi output 220 nahi araha tha kholker dekha to thori dair 220v aaye red light band hui per kuch seconds bad start hogae red light
ذبردست
Mudassarsaddiq
03056598797
سر ۔اگر کوئ ٹرانزسٹر نہ مل رہا ہو تو کیا اس کے جگہ دوسرا نمبر کا ٹرانزسٹر استعمال کرسکتے ہیں۔ مثلاً چار ٹرانزسٹر 3205 کے لگے ہیں ان میں سے ایک جل گیا اس ایک کی جگہ دوسرا نمبر 4145 لگا سکتے ہیں۔ رہنمائی فرمائیں
yes,same worke 4145 moosfet
Nice
السلام علیکم
بھائی پھر تو 1000 والا ہی ٹھیک وہ
my problem is unique,inverter can be on everything fine but as soon as u put load it starts flactuating
Check AC section mosfet or double diode
Out put falt
Sooper invetr
Mujhe bhi aisa chaiye
thanks a lot
Good
Yes
@@ACDCXYZ
FHP 740 KI JAGA IRF 740 USE KR SKTY HEN ?
FHP740 acha he ya IRF740
بھائی میرے پاس soure sta1000 inverter ہے اس کی كلمپ الٹ لگ گئے تھے اب وہ شارٹ ہو گیا ہے میں اس کی تمام mosfit ڈی سی والی Hy3506 نکال کر irf 1906 لگا دی ہیں لیکن ابھی بھی شارٹ ہے
کیا خراب ہو سکتا ہے
Hi
I love y
Sir inverter ki output DC to ac converter ki vmosfet baisng kitni kitni honi chahi
@@theexpertssolar irf740 wali side ka
Price
Hello bahi jan
Yar apna number da do ha WhatsApp ma na ap ak bat pochni ha inverter ka bara ma
WhatsApp number
@@theexpertssolar thanks
1000 watt inverter current battery pi raha hai repairing ki video banao
Ssaaz hatain varnaa hum dislike kertay hain
Dear irf ki jgga hm 12N60 lga skty hean ya nhe
Mera inverter Chal raha h out put voltage bhi dyraha hlkn thori dair K bad AC voltage oo hojata h Kia fault h plz batao