Diesel generator Training for Begginers n Expert level - Engine hunting , governor connection

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • Diesel generator Training for Begginers n Expert level - Engine hunting , governor connection
    #dieselgenerator #training #engineering
    Best technical video tutorials
    1. Dse 7320 full course video tutorial
    lnkd.in/dCPHvrk
    2. How to read Electrical Drawings Video tutorial
    lnkd.in/g8v6BEG
    3.how to bypass generator AVR
    lnkd.in/dP6Xn-Kd
    4. Three phase genrator excitation system video tutorial
    lnkd.in/dE8ZDz3
    #generator #dieselgenerator #generators #Electricgenerator #electricalengineering #electricalengineers #Engineering
    #Electrical #techjobs #technicalsupport
    DSE Programming in Urdu/Hindi Chapter -1
    Video Link: • DSE generator controll...
    DSE Programming in Urdu/Hindi Chapter -2
    Video Link: • How to do basic config...
    DSE Programming in Urdu/Hindi Chapter -3
    video Link: • DSE program Urdu /Hind...
    DSE Programming in Urdu/Hindi Chapter -4
    • DSE program Urdu /Hind...

КОМЕНТАРІ • 113

  • @DieselGeneratortraining
    @DieselGeneratortraining  Рік тому +3

    1. Dg operator practical training
    ua-cam.com/video/T77bZHVUAXM/v-deo.html
    2.Plc industrial automation free video tutorial course
    ua-cam.com/video/hk1WTmLujrA/v-deo.html
    3. Dse 7320 full course video tutorial
    ua-cam.com/video/bsZ8875Xo58/v-deo.html
    4. How to read Electrical Drawings Video tutorial
    ua-cam.com/video/IHHCT43sdYM/v-deo.html
    5.how to bypass generator AVR
    ua-cam.com/video/JzuFHKMkKyA/v-deo.html
    6. Three phase genrator excitation system video tutorial
    ua-cam.com/video/Y5jshFwHCvk/v-deo.html

  • @samuelmiru2914
    @samuelmiru2914 2 місяці тому +2

    hi, good day my 3phase generator running well but 30- 40 minutes time it switched off , without load thanks.

  • @user-ko4jt9vb3t
    @user-ko4jt9vb3t Рік тому +6

    hi sir. I can not understand how you can solve your customer problem of engine hunting? at the first part of this video you said your customer have problem with this engine . thanks for your video.

  • @abdulqadir150
    @abdulqadir150 Місяць тому +1

    Good

  • @user-jt6kc7yd1c
    @user-jt6kc7yd1c 3 місяці тому

    I have been inspired with this lesson. Very educative

  • @robertasiimwe9337
    @robertasiimwe9337 2 місяці тому +1

    Hey Muzammil thanx for your videos they are really of great importance to us Engineer but i was requesting you to take me through the synchronizing proccess right from the beginning

  • @walusansadouglas5616
    @walusansadouglas5616 Рік тому +1

    Much appreciation Eng. Muzamir,thank you for sharing this beneficial information

    • @DieselGeneratortraining
      @DieselGeneratortraining  Рік тому +1

      Ur welcome

    • @dennisbriggs1088
      @dennisbriggs1088 7 місяців тому

      Engr Muzamir, please I need ur help.There is am American generator (3-phase/60hz). And I need to convert it to 50 Hz. Please, what should I do? Expecting your reply, thanks.

  • @gacgovernorsamericacorp1383
    @gacgovernorsamericacorp1383 10 місяців тому +1

    This is a real GAC product! Yay!

  • @rafihussain
    @rafihussain Рік тому +1

    Thanks for sharing. U r doing great job

  • @EffiongBassey-yv1kj
    @EffiongBassey-yv1kj Рік тому +1

    Thanks this very educative

  • @chamindagunarathna7774
    @chamindagunarathna7774 2 місяці тому +1

    Hi sir i have problem in 400kva genarator voltage no coming rpm also how can i solve this issue please help

  • @BataDonason-ls4wp
    @BataDonason-ls4wp Рік тому +1

    Thank you Boss you are the best

  • @adeebhassan5978
    @adeebhassan5978 3 місяці тому

    Thanks sir

  • @itsok2902
    @itsok2902 Рік тому +1

    Thank you sir God Bless u

  • @oscarfucanan4618
    @oscarfucanan4618 Рік тому

    Thank you Sir for your nice explaination

  • @pranavsrajeshiii-d2303
    @pranavsrajeshiii-d2303 2 місяці тому +1

    Could you please explain about stability and gain adjustment

  • @mohameddeik9556
    @mohameddeik9556 Рік тому +1

    Thank you engineer

  • @njperez1310
    @njperez1310 Рік тому +2

    Sir can you discuss CAT CDVR and MeccAlte DECS-150. In uour opinion, which is better between the two?

  • @mohd.f.shahnewaz860
    @mohd.f.shahnewaz860 7 місяців тому +1

    Assalamu Alaikum... Boss can u tell me what is MPU and what is the function of MPU? Thanks a lot.

  • @abdulbari8855
    @abdulbari8855 15 днів тому

    As salaamu alaykum warahmatullaahi sir yaa video Hindi my bhi banayaga ji

  • @etoelectrotechinalofficer6286
    @etoelectrotechinalofficer6286 4 місяці тому

    bro, what was your hunting issue you found, when you testing you achieved from GOVERNOR actuator values of 8.9 vdc and 2 AC voltage from pick up sensor , hence where u finally reached the troubleshooting

  • @shonashona8332
    @shonashona8332 Рік тому +2

    One issue arha ha Generator under frequency shutdown
    And Generator under voltage shutdown
    But Rpm is ok and voltage also ok
    After I inactive frequency and voltage then we started Generator is working fine
    And we active generator under frequency and under voltage shutdown active then not cranking and locked out showing
    Can please help me know this issue

  • @sathishkrishnanasolar1339
    @sathishkrishnanasolar1339 9 місяців тому

    Thank you bro❤❤👍

  • @maxy437
    @maxy437 6 місяців тому

    You should disconnect component from governor and then check resistance.

  • @verhillovalakay5393
    @verhillovalakay5393 4 місяці тому +1

    Sir nice job...❤❤❤but you very fast talking😂😂😂

  • @vikramnanavare8484
    @vikramnanavare8484 Рік тому +1

    Sir please make a video of governer settings for synchronisation of 2 Nos DG set

  • @faridfarido6659
    @faridfarido6659 Місяць тому

    What to do in case where generator trips with under speed while connecting load.

  • @marizbuay5265
    @marizbuay5265 6 місяців тому +1

    Sir cranking only theirs no suplly to push the actuator

  • @mechanicdodz
    @mechanicdodz Рік тому

    Thank you for sharing sir 'i have the trouble generator perkens 102kva''engine it has working''but no have the outpot ac supply'

  • @georgebush981
    @georgebush981 22 дні тому

    Hai sir... we have the same model band new Genarator...lastday we tried to start the genarator...we checked the basic parameters, then i gave command in manual mode...engine is cranking but not start with fuel. I tried many times the same problem....Can you help me how can i fix this issue

  • @user-jt6kc7yd1c
    @user-jt6kc7yd1c 3 місяці тому

    Pro muzzamil what could be the problem ever with the generator running idle and not to the rated speed 1500rpm speed. Hence Undervoltage

  • @korushmw4896
    @korushmw4896 8 місяців тому

    Teach how to wire the governor of the Perkiniz 1106 motor to the DPSI 6021 controller board. Thank you.

  • @EffiongBassey-yv1kj
    @EffiongBassey-yv1kj Рік тому

    Explain on configuring on dcec dongfeng Cummins 4bta3.9-g13 control module

  • @sahanas.r9360
    @sahanas.r9360 Рік тому +1

    Sir, how to take stop signal externally by push button in kg934 62.5 kva genr,

  • @dennistejada2173
    @dennistejada2173 4 місяці тому +1

    I have a question.i start generator then will start.after 2 second will stop.what should i do.please helped me.

  • @yourcomedychannel8027
    @yourcomedychannel8027 8 місяців тому

    How can I sync and parallel 4 generators where gen 1 and 2 is using a deepsea 8610 module and gen 3 and 4 using ComAp NTC controller.

  • @dennisbriggs1088
    @dennisbriggs1088 7 місяців тому +1

    Muzamir,how can i convert an American generator (60 hz) to Uk generator (50 hz).

    • @DieselGeneratortraining
      @DieselGeneratortraining  7 місяців тому

      Contact me on : muzammiloger@hotmail.com with ur full details and generator details

  • @EdmondNgologwana-nj2qv
    @EdmondNgologwana-nj2qv Рік тому +1

    Sir I need a d500 control panel kj power generator configuration

  • @Tanha_8817
    @Tanha_8817 4 місяці тому

    How to reduce or increase the running meter of the generator

  • @benzblogsVlogs
    @benzblogsVlogs Рік тому +1

    In this speed controller connection i saw that this connection will run direct to speed 1800 no idle correct me if im wrong

  • @B.S_eaditor_ff
    @B.S_eaditor_ff 8 місяців тому +1

    500 kva dg ke bare mein batao pl

  • @muhamadasim8673
    @muhamadasim8673 Рік тому +1

    Bro if there is no governor, it can work right only we cannot control the control the fuel consumption

    • @DieselGeneratortraining
      @DieselGeneratortraining  Рік тому +1

      It depends on your Generator fuel system

    • @muhamadasim8673
      @muhamadasim8673 Рік тому

      Yr I am confuse with electronic engine and mechanical engineer can please share some info or data

  • @abhilashaugustine8827
    @abhilashaugustine8827 24 дні тому

    What's mean by digital input c warning

  • @hermantoofa1868
    @hermantoofa1868 Рік тому +1

    Hi bro
    I would like to change the coupling of the alternator, 400v triphase with neutral series star to 220v triphase parallel star triphase.what about to the deep sea controller ? Are there any setting to change? Change the wiring?

  • @dennisbriggs1088
    @dennisbriggs1088 7 місяців тому +1

    How can I convert generac gas generator running on 60 Hz to 50 Hz?

  • @velusamypothiraj2300
    @velusamypothiraj2300 Рік тому +1

    How to wiring in between dse controller and governor

  • @user-wd3hb9vb3d
    @user-wd3hb9vb3d 9 місяців тому

    Sir I can not know how to set configuration system please you guidelines me lot of thanks I live in Pakistan

  • @gopeshbaichan3887
    @gopeshbaichan3887 Рік тому +1

    Hi sir I do not know if u can help me in the parallel operation with generator where the pf on one alternator is fluctuate but the other is stable

  • @Roatones
    @Roatones 11 місяців тому

    Sir you have a video about Cummins 100kva hard start? thanks..

  • @kaisirahmedvlog8428
    @kaisirahmedvlog8428 Рік тому +1

    Coolant sensor fault, show display and engine shutdown,how can I do

  • @BataDonason-ls4wp
    @BataDonason-ls4wp Рік тому +1

    I really wish I can get in contact with you sir

  • @teklukifle9910
    @teklukifle9910 Рік тому +1

    how i set the Generator availability of singe phase and three phase on Digital ATS
    L-N=220V
    L-L=380V
    NOT VISBLE during the Gentor running

  • @farhanshoukat9901
    @farhanshoukat9901 Рік тому +1

    Plz make this topic video in Urdu 30 to 40 min

  • @amg3434
    @amg3434 5 місяців тому

    What is the best brand? 4G

  • @irshadnaik3524
    @irshadnaik3524 Рік тому +1

    My next q without mpu can start generator posibble

  • @mugabogabriel-rp9se
    @mugabogabriel-rp9se 4 місяці тому

    Hi explain to how you can solve the problem when generator display power up in screen

  • @bobmulenga7786
    @bobmulenga7786 2 місяці тому +1

    Uli wauyo kabwalala

  • @kelechiarinze7977
    @kelechiarinze7977 11 місяців тому

    Hi good morning, I don't understand where and what the actuator does

  • @user-fo5sw3lv5c
    @user-fo5sw3lv5c Рік тому +2

    هلا فيك ممكن كود شاشه EMS927 V3

  • @Umfuntv786
    @Umfuntv786 Рік тому +1

    Assalamu alaikum Engineer
    SDMO GENERATOR VOLVO ENGINE CRANK THREE TIMES BUT UNABLE TO START PLEASE SUGGEST SOME SOLUTION

  • @shaynegaudet6131
    @shaynegaudet6131 Рік тому

    Lf9000 oil

  • @irshadnaik3524
    @irshadnaik3524 Рік тому +1

    Asslamualaikum sir how can chainge ovltage means 380 convert 220 xplain me

    • @DieselGeneratortraining
      @DieselGeneratortraining  Рік тому +1

      Video available

    • @MEYMATO
      @MEYMATO 3 місяці тому

      Sir,communication is lost, this is FI GENARATER WAS Cat,500kw,feeding 10vDc 410AcV but without control control panel

  • @mohamedhanyf278
    @mohamedhanyf278 Рік тому

    Ahsalaam Alaikum
    I am Mohamed Haneef from Maldives
    I have got an issue from the Generator Cummins KTA19G4
    It gets RPM variation between 1512 1506 1497 1488 etc when start it but the voltage is good
    So how can trouble it and how to Mach actuator with control card some one asked me we have to Mach both of no before fixed it
    I hope you can help me

    • @mohamedhanyf278
      @mohamedhanyf278 Рік тому +1

      I need to know how to troubleshoot it and how to check MPU and Actuator

    • @kevin00861
      @kevin00861 Рік тому

      For the magnetic pick up sensor,
      Run the engine,
      Check with multimeter the AC voltage at the speed control terminals of the MPU,
      You should get between 1 & 1.5 VAC

  • @Layaqathayatkhan
    @Layaqathayatkhan 9 місяців тому +1

    View 25k and like zero what happened

  • @alejandrocastor4274
    @alejandrocastor4274 4 місяці тому +1

    Check your mpu

  • @usmanbhatti5804
    @usmanbhatti5804 Рік тому +1

    Teacher tell me your Instagram
    There is no show on UA-cam about?

  • @user-ut8wt3pz6v
    @user-ut8wt3pz6v Рік тому +1

    Please I want to have your contact please 🙏, my name is mustapha Ismail from Nigeria,I work at Topclass and we go for AJ power.
    Please I need your contact for personal assistant, for any problem about connection.
    May Allah help us and AJ power,I want you to be my boss Muzammil Ismail.
    Am Mustapha Ismail,I love your lectures.

  • @imranraza4331
    @imranraza4331 Рік тому +1

    Can I get number sir

  • @shuhayldaniels82
    @shuhayldaniels82 Рік тому

    Are you on WhatsApp?

  • @shaharulislam203
    @shaharulislam203 Рік тому +1

    Thanks sir

  • @user-py2zr9qs7l
    @user-py2zr9qs7l Рік тому +2

    How to change hour reading?

    • @IjazAhmad-bo3wy
      @IjazAhmad-bo3wy Рік тому

      Same issue is with me if u have solved then reply me