How To Joint Underground Cable | Underground Cable Straight Joint | 11kv Xlpe Cable Joint | MM Asif

Поділитися
Вставка
  • Опубліковано 31 січ 2025
  • ♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE
    Hello! Friends I am Muhammad Asif Ek Aur new video ♥ How To Joint Underground Cable | Underground Cable Straight Joint | 11kv Xlpe Cable Joint | MM Asif | ke sath Huzoor Hoon.
    straight joint of underground cable
    #Underground_Cable_Junct
    #Straight_Joint
    Their aluminium wire armour (AWA) for single core cables and steel wire armour (SWA) for multicore cables provide robust mechanical protection making these 11kV cables suitable for direct burial in the ground. These armoured MV mains power cables are more commonly supplied with copper conductors but they are also available with aluminium conductors upon request to the same standard. The copper conductors are stranded (Class 2) whereas the aluminium conductors are compliant to the standard using both stranded and solid (Class 1) constructions.
    Conductor?
    Class 2 stranded copper or Class 1 solid /Class 2 stranded aluminium
    Conductor Screen?
    Semi-conductive Cross-Linked Polyethylene (XLPE)
    Insulation?
    XLPE
    Insulation Screen?
    Semi-conductive XLPE
    Meri video acchi Lage toh please like Kijiye comments kijiye aur mere is channel ko jis ke NAME ♥MM ASIF hy is ko subscribe kijiye Shukriya. aapka Pyara dost Mehar ♥Muhammad Asif.
    ♥Plz subscribe kijiye
    www.youtube.co....
    ♥ ♥ ♥ ♥_____/LINKS\_____♥ ♥ ♥ ♥
    ► Facebook Page:➜ / mm-asif-564997130539877
    ► Instagram:➜ / asifshazada. .
    ► Google+:➜plus.google.co....
    ► linkedin:➜linkedin.com/in/mm-asif-918258173
    ====__|Watch More Videos|__====
    ♥How To Electrical Pole Size In Urdu/Hindi | Types Of Electrical Pole Stay | Bijli Ka Khamba |
    ► • How Many Types Of Elec...
    ♥How To Use High Voltage Tester | Electric Detector Work | High Voltage Detector | Urdu/Hindi
    ► • High Voltage Detector ...
    ♥How To CT Energy Meter Connection | 3 Phase CT Meter | CT Installation In Urdu/Hindi |
    ► • How To CT Energy Meter...
    ♥How To Cable Size | Cable Size Chart | Cable Size Chart With Load | Cable Size Chart In Urdu/hindi
    ► • How To Cable Size | Ca...
    ♥How To Use Hilti Gun | Hilti Nail Gun | Hilti Powdered Actuated Tools | INTRODUCING | Urdu/Hindi
    ► • How To Use Hilti Gun |...
    ♥Fire In Electrical Store In Riyadh Saudi Arabi | Al janahain | الجناحین الریاض سعودی عرب
    ► • Electrical Fire In Wal...
    ♥Electrical Work Maintenance In Saudi Arabia Urdu/hindi
    ► • Electrical Maintenance...
    ♥Fuse Lagaane Ka Tarika 33kv/11kv Urdu/Hindi
    ► • Electrical Fuse Types ...
    ♥Track: Weero - Mates [NCS Release]
    Music provided by NoCopyrightSounds.
    Watch: • Weero - Mates | House ...
    Free Download / Stream: ncs.io/MatesYO
    how to joint underground cable,
    underground cable straight joint,
    11kv xlpe cable joint,
    MM Asif,

КОМЕНТАРІ • 84

  • @fibconetfttxsupplier2424
    @fibconetfttxsupplier2424 4 місяці тому

    Your underground cable installation process is carried out with great enthusiasm. As an optical cable manufacturer, looking forward to seeing some videos showcasing your cable installation procedures.😘

  • @showdebolajandirasp100fute9
    @showdebolajandirasp100fute9 Рік тому +3

    Congratulates, It's amazing services 😮

  • @xx__p_o_k_k_u__xx3243
    @xx__p_o_k_k_u__xx3243 Рік тому +1

    Салам Алейкум, я с Кавказа и тоже кабельщик, интересно посмотреть как работают братья в других странах)

    • @paulpivnev5027
      @paulpivnev5027 Рік тому

      Ну я бы своим за такое руки обломал...

  • @sn7123
    @sn7123 Рік тому +14

    Also the heat shrinkable sheath should be heated from center to outwards. This is the correct procedure...😮
    Otherwise air bubbles may lock inside your joint.

    • @ZookLife
      @ZookLife Рік тому +3

      Make a video and show it

    • @sinoperture
      @sinoperture 9 місяців тому

      @@ZookLife You can search for it, if need be.

    • @UKsystems
      @UKsystems 5 місяців тому

      @@ZookLife quite often people can’t film them doing their job and I don’t think it’s within the scope to buy some of this cable for a video

  • @I_can_work
    @I_can_work Рік тому +1

    Nice video ok brother ❤❤

  • @ArifHosen-w7f
    @ArifHosen-w7f 2 місяці тому

    Nice bro❤

  • @UmarSharif
    @UmarSharif Рік тому +2

    Excellent Work!!!!!!!
    👍👍👍👍👍👍👍👍👍👍👍
    👏👏👏👏👏👏👏👏👏👏👏

  • @zaqirkhan
    @zaqirkhan Рік тому

    Good job⭐👍

  • @trevormitchell4913
    @trevormitchell4913 4 місяці тому

    At 8:10 is what we dont practice greasing up the semicon and then back to the connector or back onto the insulation because the properties being semi conductive can create a path that makes for electricity to flow. Just my 5 cents, still looks good though.

  • @pathan739
    @pathan739 Рік тому +1

    Good work bro

  • @yesudasmngyeaudasmng5241
    @yesudasmngyeaudasmng5241 3 місяці тому

    ❤❤❤ bhai sap. Konsa konsa material chakiye dhoda pathavuna ji

  • @DM-hk8gz
    @DM-hk8gz Рік тому +1

    Good job guys 👍

  • @YousifEissa
    @YousifEissa 2 місяці тому

    Hey, can u make a video about earthing points and ground rods for unit substation and rmu. Thanks for informative videos

  • @ranababarali7070
    @ranababarali7070 Рік тому +1

    Mashallah,bhai in cable ki life kitni ha open kay mukablay main

  • @abdulahmed9508
    @abdulahmed9508 Рік тому

    Assalamalaikum iam India Telangana c bhai

  • @현영-m7c
    @현영-m7c Рік тому

    한국 154kV 작업의 경우 준 크린 구역으로 크리닝과 접속부 이물질 방지와 전선 직진도와 고정에 주의를 한답니다. 잘 보았네요

  • @abidali.6873
    @abidali.6873 7 місяців тому +1

    Good 👍

    • @mmasif7364
      @mmasif7364  7 місяців тому

      Thanks for the visit

  • @nabiashraf6640
    @nabiashraf6640 Рік тому

    Mashallah

  • @brandonfrancis8696
    @brandonfrancis8696 5 місяців тому

    Joints shoud be spaced apart horizontally to avoid arcing (especially in HV) in case of insulation problem.

  • @Electricalpower96
    @Electricalpower96 Рік тому

    Hard work 👍@electricalpowerpk

  • @nobita2872
    @nobita2872 2 місяці тому

    How did you detect the location of fault.

  • @ShaheenKhan-uj4kz
    @ShaheenKhan-uj4kz 11 місяців тому +1

    😢❤Todays the 😊😊😊tooll 3 day and wayer 12 mater . Timer or taarem😮🎉❤😊😊

  • @PeterJD35
    @PeterJD35 Рік тому +1

    Not the correct contact plate for the crimper. This might work in an emergency but I would absolutely want to thermal test that joint over rated load to make sure it's good.

  • @dhanarajp5771
    @dhanarajp5771 7 днів тому

    how much it cost to underground electric wire in india

  • @PeterJD35
    @PeterJD35 Рік тому

    And the single phase wrap order is wrong. Glass then rubber than mastic. The shrink sheathe might provide enough insulation on its own. Prefer wide glass cloth instead of glass tape. That grease could provide a shorting path if it gets contaminated. Would rather use spray talc or PTFE tape.

  • @thembelihlezulu2474
    @thembelihlezulu2474 9 місяців тому

    I have a question, why to other side is long and the other of the cable is short what is the main reason

  • @chevalierguillaume4834
    @chevalierguillaume4834 Рік тому +13

    Where are the Wago when you need it ?

    • @davidhamm5626
      @davidhamm5626 Рік тому +2

      Exactly what I was thinking...

    • @YuriWhite2251
      @YuriWhite2251 Рік тому +1

      Вам дай волю вы в туалете станете ваго вставлять... Бгг

  • @Cartoonofficial7
    @Cartoonofficial7 Рік тому

    Sir ya training kha sy mily gii

  • @wesleyashley99
    @wesleyashley99 Рік тому +1

    If they were connected in a staggered pattern there would be less of a bulge and wires should be color coded to make sure they don't get connected in the wrong order.

    • @UKsystems
      @UKsystems 5 місяців тому

      In this case, they’re probably going to do phase testing to work out the crack sequence or it may be a case when simply the only connections they have are single phase

  • @animelover8971
    @animelover8971 9 місяців тому +1

    Bro mera interview ha cable jonter k pls help me???

  • @_mo_5169
    @_mo_5169 Рік тому +1

    Could you please tell the toold4name and every name of each percdure you did

  • @sudeepchakraborty5084
    @sudeepchakraborty5084 Рік тому

    Ye background music to angey prash ke Aladdin wale series kahai

  • @WaseemAkhtar5
    @WaseemAkhtar5 Рік тому

    Australian building technology Ltd co kaisa hai Saudi Arabia me

  • @gregwilliams386
    @gregwilliams386 9 місяців тому

    Looks like what a salesman would offer a bureaucrat. A lot of parts and labor.

  • @pedrobritez8553
    @pedrobritez8553 Рік тому +2

    Com el espacio que tiene devio hacer empalme escalonado para diminuir bulto en la aislacion y disipación de la temperatura que surgiera en el empalme

    • @ZookLife
      @ZookLife Рік тому

      Make video and show how

  • @bluka5777
    @bluka5777 Рік тому

    How you know if the phases are correct in the 3 conductor cable ?

    • @Siranjeevi1
      @Siranjeevi1 11 місяців тому

      In Singapore we put a facing kit on the far end and we pick up the color on the jointing side 😊

    • @UKsystems
      @UKsystems 5 місяців тому

      There are phase tests that will tell you the correct

  • @parthkanani9249
    @parthkanani9249 Рік тому +1

    Which Tool Is Used To Crimp The Lug??

  • @possolipossoli7451
    @possolipossoli7451 18 днів тому

    As emendas foram executadas com o maior rigor possível, só não concordo que foram no mesmo ponto e nada minha opinião deveriam ser distantes umas das outras .

  • @ammaraloush6313
    @ammaraloush6313 11 місяців тому

    Dear sir ,, How you can identify the route of of cable ?

    • @UKsystems
      @UKsystems 5 місяців тому

      If you’re going to be digging or putting anything in the ground you should take appropriate measures to locate cables request maps of where they are and use detection equipment but these will likely have posts marking their location or some plastic tape in the ground that is thick and a distance above

  • @TuberNguyen
    @TuberNguyen Рік тому

    Sao các bạn không đổ keo chống rò điện lên như thế nó đảm bảo hơn khi đấu nối chôn xuống đất..

  • @slurpy7197
    @slurpy7197 3 місяці тому

    We are cable jointer

  • @sn7123
    @sn7123 Рік тому +4

    Y 3 joints are at the same place?! It should be at 3 different places for better efficiency.

  • @masumhossain5966
    @masumhossain5966 Рік тому +1

    KSA 3 phase meter working best 3 company ka naam bolo

  • @jxwirecable
    @jxwirecable Рік тому +1

    Aluminum cable

  • @rohitmixlyricsraj2109
    @rohitmixlyricsraj2109 Рік тому

    السلام عليكم

  • @noelfaithfulkari2857
    @noelfaithfulkari2857 Рік тому

    No description on the procedure's. Names of items used

    • @UKsystems
      @UKsystems 5 місяців тому

      I mean, this is not really a tutorial video as to do this. You should have the proper training anyway.

  • @christopherswanton4796
    @christopherswanton4796 11 місяців тому +3

    another ticking timebomb, HV jointing needs to be dead on balls accurate to the mm, no gaps, perfect moisture and air seals ..that is definatly going to fail. and proper shit cables

  • @sameetbehera7861
    @sameetbehera7861 11 місяців тому

    Mastik tube exple me

  • @rajaadnan2165
    @rajaadnan2165 Рік тому

    Company ka ky name ha

  • @biok2006
    @biok2006 Рік тому

    Mute voice next time
    No sense listen voices at 2x

    • @2loco
      @2loco Рік тому

      Turn down your volume lol

  • @rohitmixlyricsraj2109
    @rohitmixlyricsraj2109 Рік тому +1

    Bai abka fohn nambbar dedo

  • @christopherswanton4796
    @christopherswanton4796 11 місяців тому

    iwork as a hv jointer on offshore windfarms, anyone who thinks this is good, give your a head a wobble, it takes me 2 maybe 3 hours to properly prepare 1 core for termination...from the very start ...shit, the semi con for example needs to be a perfect transition to insulation the sudden dip will lock air, and or water, with the biuld up of energy and heat that air pocket then triggers something called the corrona affect, I.E ironisation, AKA air becomes conductive, just like lightning, and BOOOOOOOOM failure, thats not even looking into the rest, not to mention no cleaning sanding or heating of cable to create a perfect moisture seal before the joint, cable shit procedure shit joint mega shit, not these guys fault ..untrained and unaware

    • @UKsystems
      @UKsystems 5 місяців тому

      Your times are way too long then you can find the training videos with the manufacturer of the connector and they do it all in about 15 minutes and that’s the spec they tested it too

  • @paulpivnev5027
    @paulpivnev5027 Рік тому

    Это кабель из сшитого полиэтилена? Его нужно специальными ножами разделывать 😢😢😢

  • @phenry5083
    @phenry5083 Рік тому +4

    Direct Burial? Yeah.. no. Absolutely not.

    • @UKsystems
      @UKsystems 5 місяців тому

      Please say what the actual issue is here this case this is a joint rated for this. The location is going to be properly recorded. Yes it will require digging to access but it also stops easy cable theft and the cable is likely marked with posts periodically and people are very much aware that it exists. There is likely, thick plastic protective tape a meter above so anyone digging will be aware

    • @phenry5083
      @phenry5083 5 місяців тому +1

      Direct burial is shit. This is poor quality cable and a poor quality splice. No need to expose it to the elements when conduit exists. Nobody is going to steal it either way because they’ll be turned into fried chicken if they try. Nobody is aware it exists, people aren’t that smart. “Thick plastic protective tape” isn’t going to do a damn thing. This entire thing is janky.

    • @UKsystems
      @UKsystems 5 місяців тому

      @@phenry5083 this cable is appropriately rated and protected. It is fine.

  • @miroslavzatko1477
    @miroslavzatko1477 Рік тому

    Celé zle.cele zle
    Kokoty

  • @venkatarr
    @venkatarr Рік тому

    BGM is worst 🥴🥴

  • @mdsahidali1160
    @mdsahidali1160 11 місяців тому

    Saudi mey hai aap to number send kijiyega please