How To Joint Underground Cable | Underground Cable Straight Joint | 11kv Xlpe Cable Joint | MM Asif
Вставка
- Опубліковано 31 січ 2025
- ♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE
Hello! Friends I am Muhammad Asif Ek Aur new video ♥ How To Joint Underground Cable | Underground Cable Straight Joint | 11kv Xlpe Cable Joint | MM Asif | ke sath Huzoor Hoon.
straight joint of underground cable
#Underground_Cable_Junct
#Straight_Joint
Their aluminium wire armour (AWA) for single core cables and steel wire armour (SWA) for multicore cables provide robust mechanical protection making these 11kV cables suitable for direct burial in the ground. These armoured MV mains power cables are more commonly supplied with copper conductors but they are also available with aluminium conductors upon request to the same standard. The copper conductors are stranded (Class 2) whereas the aluminium conductors are compliant to the standard using both stranded and solid (Class 1) constructions.
Conductor?
Class 2 stranded copper or Class 1 solid /Class 2 stranded aluminium
Conductor Screen?
Semi-conductive Cross-Linked Polyethylene (XLPE)
Insulation?
XLPE
Insulation Screen?
Semi-conductive XLPE
Meri video acchi Lage toh please like Kijiye comments kijiye aur mere is channel ko jis ke NAME ♥MM ASIF hy is ko subscribe kijiye Shukriya. aapka Pyara dost Mehar ♥Muhammad Asif.
♥Plz subscribe kijiye
www.youtube.co....
♥ ♥ ♥ ♥_____/LINKS\_____♥ ♥ ♥ ♥
► Facebook Page:➜ / mm-asif-564997130539877
► Instagram:➜ / asifshazada. .
► Google+:➜plus.google.co....
► linkedin:➜linkedin.com/in/mm-asif-918258173
====__|Watch More Videos|__====
♥How To Electrical Pole Size In Urdu/Hindi | Types Of Electrical Pole Stay | Bijli Ka Khamba |
► • How Many Types Of Elec...
♥How To Use High Voltage Tester | Electric Detector Work | High Voltage Detector | Urdu/Hindi
► • High Voltage Detector ...
♥How To CT Energy Meter Connection | 3 Phase CT Meter | CT Installation In Urdu/Hindi |
► • How To CT Energy Meter...
♥How To Cable Size | Cable Size Chart | Cable Size Chart With Load | Cable Size Chart In Urdu/hindi
► • How To Cable Size | Ca...
♥How To Use Hilti Gun | Hilti Nail Gun | Hilti Powdered Actuated Tools | INTRODUCING | Urdu/Hindi
► • How To Use Hilti Gun |...
♥Fire In Electrical Store In Riyadh Saudi Arabi | Al janahain | الجناحین الریاض سعودی عرب
► • Electrical Fire In Wal...
♥Electrical Work Maintenance In Saudi Arabia Urdu/hindi
► • Electrical Maintenance...
♥Fuse Lagaane Ka Tarika 33kv/11kv Urdu/Hindi
► • Electrical Fuse Types ...
♥Track: Weero - Mates [NCS Release]
Music provided by NoCopyrightSounds.
Watch: • Weero - Mates | House ...
Free Download / Stream: ncs.io/MatesYO
how to joint underground cable,
underground cable straight joint,
11kv xlpe cable joint,
MM Asif,
Your underground cable installation process is carried out with great enthusiasm. As an optical cable manufacturer, looking forward to seeing some videos showcasing your cable installation procedures.😘
Congratulates, It's amazing services 😮
Салам Алейкум, я с Кавказа и тоже кабельщик, интересно посмотреть как работают братья в других странах)
Ну я бы своим за такое руки обломал...
Also the heat shrinkable sheath should be heated from center to outwards. This is the correct procedure...😮
Otherwise air bubbles may lock inside your joint.
Make a video and show it
@@ZookLife You can search for it, if need be.
@@ZookLife quite often people can’t film them doing their job and I don’t think it’s within the scope to buy some of this cable for a video
Nice video ok brother ❤❤
Nice bro❤
Excellent Work!!!!!!!
👍👍👍👍👍👍👍👍👍👍👍
👏👏👏👏👏👏👏👏👏👏👏
Thank you so much 😀
Good job⭐👍
At 8:10 is what we dont practice greasing up the semicon and then back to the connector or back onto the insulation because the properties being semi conductive can create a path that makes for electricity to flow. Just my 5 cents, still looks good though.
Good work bro
Thank you so much 😀
❤❤❤ bhai sap. Konsa konsa material chakiye dhoda pathavuna ji
Good job guys 👍
Hey, can u make a video about earthing points and ground rods for unit substation and rmu. Thanks for informative videos
Mashallah,bhai in cable ki life kitni ha open kay mukablay main
Assalamalaikum iam India Telangana c bhai
한국 154kV 작업의 경우 준 크린 구역으로 크리닝과 접속부 이물질 방지와 전선 직진도와 고정에 주의를 한답니다. 잘 보았네요
Good 👍
Thanks for the visit
Mashallah
Joints shoud be spaced apart horizontally to avoid arcing (especially in HV) in case of insulation problem.
Hard work 👍@electricalpowerpk
How did you detect the location of fault.
😢❤Todays the 😊😊😊tooll 3 day and wayer 12 mater . Timer or taarem😮🎉❤😊😊
Not the correct contact plate for the crimper. This might work in an emergency but I would absolutely want to thermal test that joint over rated load to make sure it's good.
how much it cost to underground electric wire in india
And the single phase wrap order is wrong. Glass then rubber than mastic. The shrink sheathe might provide enough insulation on its own. Prefer wide glass cloth instead of glass tape. That grease could provide a shorting path if it gets contaminated. Would rather use spray talc or PTFE tape.
I have a question, why to other side is long and the other of the cable is short what is the main reason
Where are the Wago when you need it ?
Exactly what I was thinking...
Вам дай волю вы в туалете станете ваго вставлять... Бгг
Sir ya training kha sy mily gii
If they were connected in a staggered pattern there would be less of a bulge and wires should be color coded to make sure they don't get connected in the wrong order.
In this case, they’re probably going to do phase testing to work out the crack sequence or it may be a case when simply the only connections they have are single phase
Bro mera interview ha cable jonter k pls help me???
Kahan
Could you please tell the toold4name and every name of each percdure you did
Ye background music to angey prash ke Aladdin wale series kahai
Australian building technology Ltd co kaisa hai Saudi Arabia me
Looks like what a salesman would offer a bureaucrat. A lot of parts and labor.
Com el espacio que tiene devio hacer empalme escalonado para diminuir bulto en la aislacion y disipación de la temperatura que surgiera en el empalme
Make video and show how
How you know if the phases are correct in the 3 conductor cable ?
In Singapore we put a facing kit on the far end and we pick up the color on the jointing side 😊
There are phase tests that will tell you the correct
Which Tool Is Used To Crimp The Lug??
Battery powered crimper !!
As emendas foram executadas com o maior rigor possível, só não concordo que foram no mesmo ponto e nada minha opinião deveriam ser distantes umas das outras .
Dear sir ,, How you can identify the route of of cable ?
If you’re going to be digging or putting anything in the ground you should take appropriate measures to locate cables request maps of where they are and use detection equipment but these will likely have posts marking their location or some plastic tape in the ground that is thick and a distance above
Sao các bạn không đổ keo chống rò điện lên như thế nó đảm bảo hơn khi đấu nối chôn xuống đất..
We are cable jointer
Y 3 joints are at the same place?! It should be at 3 different places for better efficiency.
Hv joint as pr SEC STANDARD😊
KSA 3 phase meter working best 3 company ka naam bolo
Aluminum cable
السلام عليكم
No description on the procedure's. Names of items used
I mean, this is not really a tutorial video as to do this. You should have the proper training anyway.
another ticking timebomb, HV jointing needs to be dead on balls accurate to the mm, no gaps, perfect moisture and air seals ..that is definatly going to fail. and proper shit cables
Mastik tube exple me
Company ka ky name ha
Mute voice next time
No sense listen voices at 2x
Turn down your volume lol
Bai abka fohn nambbar dedo
iwork as a hv jointer on offshore windfarms, anyone who thinks this is good, give your a head a wobble, it takes me 2 maybe 3 hours to properly prepare 1 core for termination...from the very start ...shit, the semi con for example needs to be a perfect transition to insulation the sudden dip will lock air, and or water, with the biuld up of energy and heat that air pocket then triggers something called the corrona affect, I.E ironisation, AKA air becomes conductive, just like lightning, and BOOOOOOOOM failure, thats not even looking into the rest, not to mention no cleaning sanding or heating of cable to create a perfect moisture seal before the joint, cable shit procedure shit joint mega shit, not these guys fault ..untrained and unaware
Your times are way too long then you can find the training videos with the manufacturer of the connector and they do it all in about 15 minutes and that’s the spec they tested it too
Это кабель из сшитого полиэтилена? Его нужно специальными ножами разделывать 😢😢😢
Direct Burial? Yeah.. no. Absolutely not.
Please say what the actual issue is here this case this is a joint rated for this. The location is going to be properly recorded. Yes it will require digging to access but it also stops easy cable theft and the cable is likely marked with posts periodically and people are very much aware that it exists. There is likely, thick plastic protective tape a meter above so anyone digging will be aware
Direct burial is shit. This is poor quality cable and a poor quality splice. No need to expose it to the elements when conduit exists. Nobody is going to steal it either way because they’ll be turned into fried chicken if they try. Nobody is aware it exists, people aren’t that smart. “Thick plastic protective tape” isn’t going to do a damn thing. This entire thing is janky.
@@phenry5083 this cable is appropriately rated and protected. It is fine.
Celé zle.cele zle
Kokoty
BGM is worst 🥴🥴
Saudi mey hai aap to number send kijiyega please