How A Combi Boiler Works. Gas Engineer Training

Поділитися
Вставка
  • Опубліковано 5 жов 2024

КОМЕНТАРІ • 18

  • @SV_maintherm
    @SV_maintherm Рік тому +3

    Thank you Allen . Regards from Cyprus 👋

  • @darrenowen3338
    @darrenowen3338 Рік тому

    What a great teacher Roy is! The time flew by, thanks Allen.

  • @iliyadrankov5729
    @iliyadrankov5729 Рік тому

    Usfull video i watched it few times but it is from 2 years ago,can you guys do a new one with different boiler thanks
    Great video !!

  • @patrickoregan7102
    @patrickoregan7102 Рік тому

    Thankyou, Allen and Roy, is there any chance you could do a video on how to test pH levels and water testing for central heating systems please. Thanks.

  • @luisangelrevillavallecillo7166

    Muchas gracias por vuestros videos son muy interesantes TE INVITO A QUE PONGAS SUBTÍTULOS EN ESPAÑOL.

  • @petermolloy4757
    @petermolloy4757 Рік тому

    Great videos
    👍

  • @LovelyDivingBoard-ch8oq
    @LovelyDivingBoard-ch8oq Місяць тому

    please make a video on shock arrestors and do we need them Allen

  • @GasTraining
    @GasTraining Рік тому

    Is this a reupload? Remember watching this a while ago.

  • @pounts3876
    @pounts3876 Рік тому +1

    Alan if I drain the CH to remove rads on a combi and leave it drained, can they still have hot water ? I don’t think they can as use the same heat exchanger and overheat stat issue with no circulation ?

    • @AllenHart999
      @AllenHart999  11 місяців тому

      Depends on the boiler. In most cases the boiler will not work.

  • @tothertothes
    @tothertothes Рік тому

    Legend!

  • @mostunicorn
    @mostunicorn 10 місяців тому

    I have a vitodens 100w WB1C combi boiler. I noticed that the circulation pump never shuts off when in heating mode. Is that normal? It switches on/off as expected when I use it only for hot water. Starts up when I open the tap and shuts off when I close the tap. But as soon as I turn on my UFH, it just goes forever. Even on lowest setting, with smallest 20 meter loop isolated. I don't have any additional room temperature sensors or timers.
    Also, do combi boilers have a way to remove air from the system? I refilled my UFH and I could hear air going through the pipes and the boiler. But after a few hours of working, there was no air sound left. I don't have an automatic air vent on the pipes. Does this mean the air is gone, or is it now trapped in the system somewhere?

  • @malachymulhall8012
    @malachymulhall8012 Рік тому

    Alan I'm asking for a friend , is it possible to get a gas 🔥 fireplace insert with a back boiler .

    • @AllenHart999
      @AllenHart999  Рік тому +1

      not anymore but they used to make them

  • @paulmarshall3104
    @paulmarshall3104 Рік тому

    Hi Alan just a quick question about baxi duo tec 33 do i need external bypass valve for two zone heating. I know it has built-in bypass is this ok to use with zone heating. Any information would be appreciated

  • @shaxzodaminov2916
    @shaxzodaminov2916 Рік тому

    Hello. How can I connect with you. I'm in london.

  • @MickeyBlue-eyes
    @MickeyBlue-eyes Рік тому

    Sure I've seen this 2 yrs ago