How to install a Manager30 battery management system | DIY Manager30 Install

Поділитися
Вставка
  • Опубліковано 18 лис 2024
  • Ready to self install the REDARC Manager30 BMS into your 4x4, truck, camper or caravan? Follow this helpful DIY guide direct from REDARC experts to find out how.
    AU: www.redarc.com...
    NZ: www.redarcelec...
    USA: www.redarcelec...

КОМЕНТАРІ • 48

  • @OverlandArizona4690
    @OverlandArizona4690 4 роки тому +1

    Currently have your BCDC1225D but probably going to upgrade very soon to a manager30 with a RedVision display. Great products 👍

  • @1956ct
    @1956ct 2 роки тому +1

    hi great video where does the negative of the solar panel connect to in the system you spoke about the positive connection , thanks pete

    • @REDARCElectronics
      @REDARCElectronics  2 роки тому

      Hi Pete, thanks for your comment. The negative of any Solar needs to connect to the common ground of the system - eg the GND side of the Battery Sensor. This is along with all your other load negatives too, same connection process there. If you need any further assistance don't hesitate to contact our helpful Tech Support Team on 1300 REDARC.

    • @rhysjones5475
      @rhysjones5475 2 роки тому +1

      So if seting up a solar blanket when parked in shade. Positive to battery + and ground to common ground?

  • @mavo0673
    @mavo0673 4 роки тому

    I cant wait to install the full red vision system in our 4 month old jayco expanda outback and a redarc inverter and getting rid of the 50+kgs and 3 gel batterys and put 1 or 2 lithium batterys in I use redarc in my 200 series. I am not a fan at all of the battery manager system that jayco use since having our van and starting our 2 year tour of the best place we've had nothing but issue's with the battery manager system that has been used . We were always going to have the expanda fitted with redarc red vision system . The red vision system offers so much more in the unit it's every thing all in 1 unit unlike the system in the van now that has so much stuff not include it's all add on . To get to the point of the red vision system I would need to out lay alot of coin to get the battery manager system in the van now any were up to the standard of the red vision system. I would much rather spend my money on a product that i know and never had any issues with what i use from redarc now than waste my money on a system that's giving us nothing but trouble since we started our 2 year tour . There is only 1 12volt specialist and its all Australian made and owned it's redarc only the best . I even asked jayco if i was to supply the full redarc red vision system could it be fitted at the time of bulid or have the wiring run so when it come to the dealer ship it could be fitted there I was told straight out no no to both that we asked I should have expected that answer when i asked if i could up grade the battery manager system so it was lithium ready and we were told the only way i would get it was to have lithium batterys installed

    • @REDARCElectronics
      @REDARCElectronics  4 роки тому

      Appreciate your support, Andrew. And hope you and the family enjoy many great trips in the new Jayco.

  • @cooperseckold
    @cooperseckold 10 місяців тому

    what’s a rough guide on how long the battery charge cycle takes. like when you first set the display up?

    • @REDARCElectronics
      @REDARCElectronics  10 місяців тому

      Thanks for watching! A rough guide is battery size (AH) divided by 30 should equal a approximate time to calculate, providing the Manager30 is connected to mains power.

  • @mangbecak1
    @mangbecak1 4 місяці тому

    Hello!
    When im trying to charge my lithium battery via AC (240v) i can see from the remote controller that all are going into the load and not the battery itself.
    The battery is being charged via the car and the solar panel without issues.
    Any ideas where it could have gone wrong?

    • @REDARCElectronics
      @REDARCElectronics  4 місяці тому

      Hello, this is a common issue we see always relating to the battery monitor being installed incorrectly. It is important that all currant flows through the battery monitor for accurate battery information.
      For further information regarding this, we recommend contacting the REDARC technical team on 1300 733 272

  • @joelclark5630
    @joelclark5630 Рік тому

    Hi, I've got one of these in my caravan, question is, when connecting my car's battery to the manager30 via anderson plug, do i need a redarc sbi in between them or do i just run straight through with a 50A fuse?

    • @REDARCElectronics
      @REDARCElectronics  Рік тому

      Thanks for watching! The Manager30 has built in isolation and does not require a SBI or another isolator on the input of the charger.

  • @Balasubbarayan
    @Balasubbarayan 3 роки тому

    Should the components always be installed on wood?

  • @liberatingleash
    @liberatingleash 2 роки тому

    Hello, I have my system and plan on installing it next week. Re-watching the video to make sure I've got it down. However, I noticed he mentioned using 0 - 2 gauge wire in the materials to have section in the beginning, but I'm not sure where he used them and I don't see that in the instructions. Any advice will help. Thanks!

    • @REDARCElectronics
      @REDARCElectronics  2 роки тому +1

      Thank you for watching, and for your interest in REDARC products. The 0/2 B&S cable mentioned was used as the cable between the Battery, and the BNEG terminal of the Manager’s Battery Sensor.
      This is to cater for any loads that may be drawing high currents from your battery - such as an inverter or even just a lot of small loads combined.
      The reason no other mention of this cable or visual shown was due to the focus on the Manager30’s install and not the remainder of the 12V system.
      Any further questions please don't hesitate to contact our helpful Tech Support Team over the phone who will be more than happy to discuss in greater detail.

    • @liberatingleash
      @liberatingleash 2 роки тому +1

      @@REDARCElectronics ahhhh thank you. I missed that part.

  • @terryshaw1134
    @terryshaw1134 4 роки тому

    Thanks for the video, you did a great job of explaining this baby. Can you tell me how much this system weighs in at and is there a spot that I can find dimensions of the parts and pieces of the system? I would be putting it in a 1985 VW westfalia with a 2002 2.5 NA Subaru.

    • @REDARCElectronics
      @REDARCElectronics  4 роки тому +1

      Thank you for watching, Terry. You can find all the components included, sizing and product information on the product page and inside our instruction manual here redarcelectronics.com/products/the-manager30

  • @pagaddictfishingadventures694
    @pagaddictfishingadventures694 3 роки тому

    Hi Guys... Ive recently installed a RED Vision system with a Manager 30S3 and a 3000 watt Red Arc Inverter.... Awesome!! The only thing at the moment is I'm getting no info from my battery sensor..... nothing on the display.... how long will it take to register with the battery? (300 AH Invicta w Bluetooth) or how do i test to see if the battery sensor is Faulty
    Best Regards
    Brad

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      HI Brad, thanks for the message and for choosing REDARC gear. It will be best to speak with our Tech Support Team on the phone to help troubleshoot this on 1300 REDARC.

    • @pagaddictfishingadventures694
      @pagaddictfishingadventures694 3 роки тому

      @@REDARCElectronics Hi guys, crisis averted !! it took two days but the sensor is working!! The only thing i will say bad about the system is the bluetooth is terrible....if my phone is not an inch away from the display it just won't work... is that normal??

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      @@pagaddictfishingadventures694 Great to hear the sensor is working as desired. However the Bluetooth issue is certainly not normal operation, and would be best to call our Tech Team so they can run some checks with you over the phone.

  • @Balasubbarayan
    @Balasubbarayan 3 роки тому

    Do these components need to be vented if installed in an enclosed compartment? Heat dissipating fan required?

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому +1

      Hi there Bala, thanks for your message. The system can be mounted on any sort of surface, so long as it is secure. The orientation of the charging unit is important to allow for best heat dissipation; usually horizontal is ideal. It doesn’t need to be in a fully vented area as the heatsink does most of the work, but any extra flow that it can have is helpful.

  • @KipperKushman
    @KipperKushman 3 роки тому

    Can you have 2 remote monitors on the same manager 30 via splitter? For example one in cab and one camp side by the batteries.

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      Thank you for your message and yes you can run two screens using a 3-way splitter, but ensuring that the cable length is no more than 10 metres. Any further questions please feel free to contact our helpful Tech Support Team in our head office who will be more than happy to walk you through this in greater detail over the phone.

  • @ronjesche689
    @ronjesche689 3 роки тому

    Is the display unit permanently lit, or does it turn off after a period. Wanted to check first to determine placement of the display unit. Thanks

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      Hi Ron, thank you for your message. The display timeout period can be adjusted in the display settings on your system. For further assistance please don't hesitate to contact our friendly Tech Support Team.

  • @rileyblackwell4911
    @rileyblackwell4911 3 роки тому

    Hi Redarc,
    My question is regarding the fuse size between the BMS terminal 1 and the aux. battery +’ve terminal - the BMS manual advises a 40A fuse, but in this video you advise a 60A fuse.
    Can you please advise the size this fuse should be.

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому +1

      Hi Riley, thank you for your question.
      The BMS output is current limited to 30A so a 40A fuse is acceptable however a higher rated fuse is required for the input circuit. REDARC offer fuse kits in 40 and 60A variants, these fuse kits come with 4 fuses, 4 cable lugs and 2 fuse holders. Using a 60A fuse on both input and output is acceptable as the fuse is only there to protect the wiring from a short circuit and the 60A fuse would protect the wiring in this situation. Essentially either option is fine for your output fuse but the most cost effective option is to use an FK60 fuse kit to cover both bases.

  • @56nado
    @56nado 3 роки тому

    Hi i have an sbi12-lld between my aux battery and fridge. Does the earth wire get connected to the load disconnect point on the manager 30?

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      Yes, the SBI12-LLD black earth cable needs to be wired into pin 2 of the Manager30. Once this is completed you can access the Load disconnect feature in the settings menu and set the disconnect trigger. Contact our helpful Tech Support Team on 1300 REDARC to discuss in greater detail over the phone.

  • @brendansmoother
    @brendansmoother 3 роки тому

    Hi Guys, I have the 1230S2 earlier model and have been very happy with it managing 2 x AGM 100ah batteris (one in car, other on camper trailer - I just know that it reads 50% out when trailer disconected). I am going to upgrade to a lithium battery, but what I need to know is, can I inter-mix one AGM with one lithium or do I need to upgrade both batteries to be the same type and size?

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      Hi Brendan, when linking batteries in parallel it is always necessary that they are all the same size and chemistry. It is also recommended that any battery in parallel be as close as possible to the other battery to ensure the best possible charge equalisation. Any other questions please feel free to contact our Tech Support Team directly.

  • @davidcowan1583
    @davidcowan1583 4 роки тому

    Is it possiblevto have this configured to have a permanent solar setup along with a snderson plug for portable solar?

    • @REDARCElectronics
      @REDARCElectronics  4 роки тому +2

      Sure can. Give our Technical Support Team a call on 08 8322 4848 and they'll be happy to walk you through how.

  • @obahagari8544
    @obahagari8544 3 роки тому

    What size cable do I run from my start battery to the manager 30?

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому

      Hi Obaha,
      The size of the cable required will depend on the length of the cable.
      For a cable length equal or less than 3m, 8 B&S (8AWG) automotive cable with approximately 8mm² cross-sectional area is all that is required, however beyond 3m the cable should be increased to 6 B&S (6AWG) with 13.5mm² cross-sectional area.

  • @jorjimaco5331
    @jorjimaco5331 2 роки тому

    So you can’t series connect panels, just parallel ??

    • @REDARCElectronics
      @REDARCElectronics  2 роки тому

      Hi Jorgi, thanks for your comment. The Manager30 (and all our DC-DC charging systems) accept up to a maximum of 32VOC - meaning yes nominal 12V solar panels can only be connected in parallel, not series.

  • @vtxadventures6598
    @vtxadventures6598 4 роки тому

    what size lugs and heat shrink do we need?

    • @REDARCElectronics
      @REDARCElectronics  4 роки тому +1

      We recommend using cable sizes between 8 B&S/AWG and 4 B&S/AWG, depending on the length being used. Up to 3m, we recommend 8 or 6 B&S and over 3m, upgrade to 4 B&S. I would buy lugs/connectors and heatshrink to suit these sizes appropriately

  • @chrisjones1864
    @chrisjones1864 3 роки тому

    Cable ties, not zip ties

  • @davidcowan1583
    @davidcowan1583 3 роки тому +1

    Is it possible to have a switch setup to link your auxiliary battery and your start battery to jump start your car?

    • @REDARCElectronics
      @REDARCElectronics  3 роки тому +1

      Hi David, setting up a jump-start switch/solenoid from your auxiliary battery to your main is a possibility - ensuring that a separate circuit is created when doing so, rather than using the wiring that exists between the vehicle, Manager30, and the auxiliary battery. To find out more please contact our Tech Support Team on 08 8322 4848 and they'll be more than happy to walk through this in greater detail over the phone.

  • @JasonR1998
    @JasonR1998 Рік тому

    Can the ground of the shunt run back to the starter battery negative?