AUMA Actuators - Setting Limit Switches - MWG Non-Intrusive

Поділитися
Вставка
  • Опубліковано 30 січ 2025

КОМЕНТАРІ •

  • @พลวุฒิย่องเส็ง

    Good job! Very easy.

  • @troyandutan4483
    @troyandutan4483 Рік тому

    Sir how to solve erratic reading of the valve opening percentage in Remote operation.

  • @amjadasafadi6151
    @amjadasafadi6151 2 місяці тому

    How can a valve with a half-inch opening set to 20 milliamps? If another valve also has an inch opening, set to 20 milliamps?

  • @felipeandresrojaspizarro8305
    @felipeandresrojaspizarro8305 3 місяці тому

    I jave a problem setting the limits, I save the limits, then i made local test and it takes a very small route that I don't set, what is rhe problem?

  • @ilkinelcin1893
    @ilkinelcin1893 10 місяців тому

    Hello. There is a problem with the push buttons on this device. Where can we get information about their repair?

    • @Chris_Eby
      @Chris_Eby 7 місяців тому

      Comment is old but I'll reply. The buttons are magnetically operated and not serviceable without destroying the cover. Where I work as the instrument tech I take the cover off remove circuit board and use a small magnet to operate the buttons. It's not a great fix but we have about 18 of these and all the cover magnets are bad. The units we have are maybe 4 years old. Was told by Auma they had a bad batch and would send us all new ones. Still have not heard back...

  • @Vijayanrevathi-g1d
    @Vijayanrevathi-g1d 2 місяці тому

    Auma actuator MWG fail sensar 0007 what's problem sir tel me

  • @vijayanm5360
    @vijayanm5360 2 місяці тому

    Sir auma actuator MWG work shop manual need sir

  • @mdsohailakhtarkhan
    @mdsohailakhtarkhan 2 роки тому

    Why showing position undefined plz tell me sir

  • @عزالدينالقسام-ه1ش
    @عزالدينالقسام-ه1ش 9 місяців тому

    Sir, the screen is red, what is the reason for this? And you don't receive anything?

  • @nabeelasghar6883
    @nabeelasghar6883 2 роки тому

    Sir what exactly is MWG

    • @AUMAActuators-USA
      @AUMAActuators-USA  2 роки тому

      The MWG is the control unit inside our actuator. It consists of magnetic encoders that measure torque output and determines and reports actuator position. The MWG will only work with the AC01.2 motor controls and It is located in the actuator surrounded by a protective plastic casing

    • @ieptran7713
      @ieptran7713 9 місяців тому

      @@AUMAActuators-USA Sir when dose user calibrate via MWG and GTLS Mechanical limit switches? or can use either one

    • @vijayanm5360
      @vijayanm5360 2 місяці тому

      Sir AUMA actuator MWG fail sensor what's the problem