@@ninobeliali1849 Starting running lead wires can be sensed by measuring ohms with a digital multimeter, For example... Two leads ohm's - 2 ohm's Other two leads - 5 ohm's... (2 ohm's running winding ) Running winding will have lower ohm's and the starting winding will have higher ohm's.
@@Hipowerelectricworks i got the two centrifical switch wires correct have two thicker wires and two thinner wires still can't find out witch ones are run following you diagram,its very clear when the two run wires are determined
There are four wires from the motor winding and two wires from the centrifugal switch. It's a double capacitor motor connection (starting capacitor and running capacitor)
Change the connection of the running lead wire. Separate the running lead from the lead where the starting and running lead are joined and attach another running to it.
your video is the best so far i seen
how to find running and start wires
i have them all grey
@@ninobeliali1849 Starting running lead wires can be sensed by measuring ohms with a digital multimeter,
For example...
Two leads ohm's - 2 ohm's
Other two leads - 5 ohm's...
(2 ohm's running winding )
Running winding will have lower ohm's and the starting winding will have higher ohm's.
@@Hipowerelectricworks i got the two centrifical switch wires correct
have two thicker wires and two thinner wires
still can't find out witch ones are run
following you diagram,its very clear when the two run wires are determined
@@Hipowerelectricworks got it now
thick wires are the running ones with low oms
thanks
Explicaciones claras, fáciles de aprender. Dios lo colme de bendiciones.
Now I get it. Thank you very much
You're most welcome
His winding 🙏🙏🙏🙏
What's the name of that spray the help to loosen bot
WD 40
Super
ကပ်ပစီတာ ကောင်း မကောင်း ဘယ် လိုစမ်း ရပါလဲဗျာ " ကျေး ဇူး ပါ
Super explaining
Thank you
Thankyou very much brother.... Meru telugu vara sir
Thank you
Hi nice demonstration
Yekkada meedi chepthara sir
so there is 6 wires from motor on this, what if i only have 4 wires, how do i connect ?
There are four wires from the motor winding and two wires from the centrifugal switch.
It's a double capacitor motor connection (starting capacitor and running capacitor)
Thankyou
Keep watching my channel
Thank you
Sir ,not ok ,,, phase , neutral ( inter change)
Phase, Neutral inter change no problem
Nice
How do you reverse the direction of rotation
Change the connection of the running lead wire.
Separate the running lead from the lead where the starting and running lead are joined and attach another running to it.
Good job ❤
Good job dear..❤❤❤
Thank you
Very nice गुरु जी ❤❤❤❤❤❤❤
Thank you
good job 👍🏻
Thank you
Thanks
You're most welcome