REX-C100 settings

Поділитися
Вставка
  • Опубліковано 3 лис 2024

КОМЕНТАРІ • 79

  • @henrikhansen1023
    @henrikhansen1023 3 роки тому +12

    You surely get through this very easy - instead of explaining the meaning of the settings you just say: "This is correct"

  • @frenchcreekvalley
    @frenchcreekvalley 4 роки тому +6

    Excellent video. I spent many hours attempting to understand my Rex C900 using the instructions that came with it and I still didn't fully understaand what to do. You have done it for me in 7 minutes and 28 seconds. Thank you!

  • @tupatupa-var
    @tupatupa-var Рік тому

    Well done and thank you for your work. STP Possible with this REX C100, to stop heating before reaching high temperatures? , Thank you for your answers

  • @jameselisterio7711
    @jameselisterio7711 5 років тому +3

    my berme rex c100 has only 3 digits on settings the parameters, how does your become 4 digits?

  • @sermsaklimpadapun6054
    @sermsaklimpadapun6054 3 роки тому +2

    I followed your instruction and now it really stable control. Thanks a lot.

  • @miclairmiclair876
    @miclairmiclair876 3 роки тому

    I burnt 6 coils . Watched ur video, now I'm feeling confident. Thanks

  • @Appregator
    @Appregator 7 років тому +1

    Thanks, I could not get into second code table to change thermocouple type and your pressing 'Set' ans '

  • @terrencewalsh453
    @terrencewalsh453 2 роки тому

    Thank you sir, I had all settings screwed up to the point that my "K" coupler was showing as an "R"! I use it for brewing and need the brew for Christmas! Thanks again, you get a big subscribe!

  • @sdube60
    @sdube60 5 років тому +1

    Will tis shut the kiln off when the set temperature is reached? Or does it just keep the kiln from firing hotter than the set temperature.

    • @furnacestools6981
      @furnacestools6981  5 років тому

      Kiln not turn off, kiln hold set temperature.

    • @sdube60
      @sdube60 5 років тому

      @@furnacestools6981
      thanks.

  • @15ju1960
    @15ju1960 11 місяців тому

    Top Thank sir, was A nice video help me A lot verry clear nou how to the settings from A c100👍

  • @oscarlara7420
    @oscarlara7420 7 років тому +1

    es tan claro su explicación que yo sin saber hablar ingles, le entendí perfectamente, es usted un excelente maestro. gracias.

  • @fernandosilva86
    @fernandosilva86 3 роки тому

    Thank you very much friend if it weren't for you would be with a controller without any use, thanks to you I was able to configure mine and finally enter configuration 2, it was blocked thanks a lot, a big hug here from Brazil.

  • @maximebegin1454
    @maximebegin1454 Рік тому

    Concerning this PID with SSR... if I have a 10kw heating element, is there any way to decrease the frequency of the signal from the PID sent to the SSR before limiting my heating element to 9kw? For example, is there an option in the menu that allows 90% of the signal sent to the SSR instead of 100%? That would solve my problem.

    • @Biligo42
      @Biligo42 Рік тому

      No, it is not power regulator.

    • @johnle231
      @johnle231 Рік тому

      It controls temperature.

  • @pasayaman
    @pasayaman 3 роки тому

    I have a question. How is it controlled to heat the oven 10°C/min or 20°C/min? I could not set the temperature step in PID.

    • @Biligo42
      @Biligo42 3 роки тому +1

      You can't set heating speed. This function have programmable controllers only.

  • @derinkan
    @derinkan 5 років тому +2

    Excellent. Harika bir video. Bu video sayesinde tüm ayarları yapabildim. Teşekkürler

    • @pasayaman
      @pasayaman 3 роки тому

      siz sıcaklık artış hızını nasıl ayarladınız?

  • @1.tppuiiaabdulrahman734
    @1.tppuiiaabdulrahman734 Рік тому

    how do you set it so that the temperature is as desired? because yesterday I set it at 100° Celsius but the temperature continued to rise to 230° Celsius
    Please help me

  • @blutorlz3
    @blutorlz3 6 місяців тому

    Anyone see these behave strangely with the PV value jumping all over as soon as the SSR starts cycling? I’ve tried several thermocouples and two different c100 controllers. The heating element can be plugged in or disconnected and the behavior continues.

  • @firstkay
    @firstkay 3 роки тому

    hi could you please help me again i cant set hold on my rex-c100 i need to set it to hold for 4 hours at 900c could you please tell me how or do you have a video showing how im dyslexic and cant follow the manual. thank you kind regards kay.

  • @firstkay
    @firstkay 3 роки тому

    hi thank you for you easy to follow video it was so helpful to me as im dyslectic and find instructions hard to decipher. your vidio is amazing, your instructions were so clear and precise and so easy to follow. that is why im writing to you im having a problem and im hoping you can help me please. i did 2 firings then the kiln stopped heating for the next firing, it shows ambient temp and desired temp. on the left is green light (the 2nd from top) it is steady just as normal but no heat. its as if the power to the heating elements is not geting through. every thing turns on so there is power, it just wont heat up it took 30mins for the ambient temp to change from 21 to 22. but if i hold the pyrometer with my fingers it goes up rapidly as it did when it was working. is there something that cuts the power of from the element's? i would be so great full if you could help me please. kind regards kay.

    • @furnacestools6981
      @furnacestools6981  3 роки тому +1

      Based on your description of the issue, most probably the controller sends the signal for the kiln to heat up, but something inside the kiln does not work properly so the command isn't carried out. In this case your kiln probably needs to be opened up and checked inside with a voltmeter to see how the electricity goes though the networks. If the power control is assembled with the SSR relay then please take a look at the relay - does the LED light up on it when the kiln should be heating up (majority of SSR relays have such a control indicator)? If the LED does switch on then you need to check whether the high voltage (230V) reaches the relay, and whether the voltage leaves the relay at the moment when the LED lights up. These are the initial steps for the checkup. If the high voltage does not reach the relay then please check the network - maybe one of the fuses in the way to the relay has burnt out.

    • @firstkay
      @firstkay 3 роки тому

      @@furnacestools6981 hi thank you so much for all your help i really appreciate it. it wasn't the controller after all. the heating elements had a broken at the connection point.

  • @brenosilva4731
    @brenosilva4731 Місяць тому

    How to insert decimal point?

  • @HtetNaing01
    @HtetNaing01 4 місяці тому

    Thank you sir. I'm many hour in trouble but all solve in 7min.

  • @Andi-ne6rd
    @Andi-ne6rd 6 років тому +1

    Hello,
    I have a problem, the stove keeps heating up the temperature, more than set. The stove is brand new and the first use of Feher is already like that. If I set 200 C as the temperature, then the temperature in the oven goes much further up. How can I reset the settings?
    I speak and understand unfortunately little English! I'm from Germany !

    • @mihalyzsoltczeglediKNIFE
      @mihalyzsoltczeglediKNIFE 5 років тому

      Hello Andi!
      I would like to ask you to find a solution to the problem, because unfortunately, my system is setting this setting to this setting.
      Best regards Michael

    • @mihalyzsoltczeglediKNIFE
      @mihalyzsoltczeglediKNIFE 5 років тому

      I'm from Hungary!

    • @Forbidaxe
      @Forbidaxe 4 роки тому +2

      I had this problem, here is the fix...Hold set for 3 seconds to enter menu, then change ArU (ATU Auto tune) to 0001 and hold set for 3 seconds again. A light will be lit to say auto tune is on, don't interupt until light turns off, when finished hold set for 3 seconds to enter menu again and you will notice the P, I and D settings have changed, auto tune has changed these for you to better suit your situation, lower P setting for better results if your still going over.

    • @jorgevalle0876
      @jorgevalle0876 4 роки тому

      @@Forbidaxe my AT light don't turn off, what can I do??

    • @Forbidaxe
      @Forbidaxe 4 роки тому +1

      @@jorgevalle0876 Unsure, mine did feel like it was in AT for ages before going off, maybe just wait a bit longer, a pain I know whilst trying to do what it is your doing.

  • @md.abdul-almasudshuvo4735
    @md.abdul-almasudshuvo4735 7 років тому +1

    I change the functional value of rkc rex c-100, k type really out, renege (0-400). But I want to get back to previous factory setting, I want to use it for 37'c chamber fixed temperature, please send me the value of function & how to restart.

    • @I-am-not-a-number
      @I-am-not-a-number 6 років тому

      www.rkcinst.co.jp/english/pdf_manual/imnzc22e1.pdf

  • @adimichafara5030
    @adimichafara5030 4 роки тому

    Thanks. I want you help me to programm XMTD-1001 temperature controller

  • @SuperMitu11
    @SuperMitu11 3 роки тому

    Thank you for this vedio. It helps a lot.

  • @neutralgod300
    @neutralgod300 4 роки тому

    when I do the "LCY" it only has 100, I don't have 1000, what can I do?

  • @risingforce100
    @risingforce100 4 роки тому +1

    Good vídeo! How can I do to configure PID parameters?

  • @gerharddeyzel4318
    @gerharddeyzel4318 4 роки тому

    When switch my PID on it show alarm 2 and flash ooo at PV. Any advice

    • @Biligo42
      @Biligo42 4 роки тому

      Check thermocouple connection

  • @hungnguyen-mi5ft
    @hungnguyen-mi5ft 2 роки тому

    Thank you very much ,one file video very speccialy ...

  • @bethechangeme2233
    @bethechangeme2233 4 роки тому

    My temperature is stuck at 400 degree's i cannot make it go higher. Is there a way to change this?

    • @bethechangeme2233
      @bethechangeme2233 4 роки тому

      Fixed it after watching your video, thank you! Jesus saves.

  • @krisadanuwatsamurjai4429
    @krisadanuwatsamurjai4429 2 місяці тому

    How to set temp 1000c

  • @mahmoudzaki6251
    @mahmoudzaki6251 2 роки тому

    Thank u very much indeed really u have got very very big subscribed

  • @duecedog5896
    @duecedog5896 2 роки тому

    Thank you my friend.

  • @pyaesone-fb2nm
    @pyaesone-fb2nm Рік тому

    Thank you sir

  • @djhscorp
    @djhscorp 3 роки тому

    Thank you for sharing

  • @henrikhansen1023
    @henrikhansen1023 2 роки тому

    This product doesn't work. It reacts way too slow to actual changes. Once a reached threshold triggers a power cut, the temperature can be way above that limit.

  • @katharinaliebchen6673
    @katharinaliebchen6673 2 роки тому

    Super, Dankeschön

  • @EddyWiryana
    @EddyWiryana 4 роки тому

    Thank you for sharing and good expl👍

  • @rcalin9354
    @rcalin9354 3 роки тому

    Thanks!

  • @INOVUSTECHNOLOGY
    @INOVUSTECHNOLOGY 5 років тому

    Excellent!

  • @nestoraugusolopezortega975
    @nestoraugusolopezortega975 3 роки тому

    Thanks a lot!!!!!!

  • @turalmustafayev2728
    @turalmustafayev2728 2 роки тому

    Rakamlar kaldirdikca dusuyor kardirmak olmuyor

  • @nolinicolas4237
    @nolinicolas4237 3 роки тому

    Gudday sir. How about i will use for cooling sir, all i need is 16-17 C means, 16C below it will turn-off and if 17C up it will turn-on. I will use as a switch(i will pluge my refrigerator) for restoring my pig semen. Thank u and God bles

  • @Glen48m
    @Glen48m 6 років тому

    Great thanks

  • @gopinath-dz4qp
    @gopinath-dz4qp 5 років тому

    Tanks

  • @МастерЛомастер-т9ж

    Язык не сломай!

  • @phongquang6882
    @phongquang6882 7 років тому

    Helo

  • @user-1970IGOR
    @user-1970IGOR Рік тому

    Партизан я тебя раскрыл

  • @Aldobaev
    @Aldobaev 4 роки тому

    Говори по русски не стесняйся 😁

    • @low1799
      @low1799 11 місяців тому

      он немец

  • @salvadorpalma8173
    @salvadorpalma8173 4 роки тому

    I'm sorry you don't know what you are saying.

  • @jameselisterio7711
    @jameselisterio7711 5 років тому +2

    my berme rex c100 has only 3 digits on settings the parameters, how does your become 4 digits?

    • @hjvanaswegen5110
      @hjvanaswegen5110 2 роки тому

      Did you find out how to change it mine is the same.

  • @INOVUSTECHNOLOGY
    @INOVUSTECHNOLOGY 5 років тому

    Excellent!