Water Heater Needs Venting

Поділитися
Вставка
  • Опубліковано 16 жов 2024
  • Water Heater Needs Venting
    Welcome to our channel! If you enjoy our videos and would like to support us, any purchase you make through the link below will greatly contribute to the growth and improvement of our channel. Thank you for your support! [Affiliate link: amzn.to/2RCiOrW]
    In this informative video, we will guide you through the process of installing a natural gas vent pipe for your water heater. Whether your water heater is located in a garage or a closet, we'll show you the correct steps to ensure proper venting, eliminating potential hazards and enhancing the safety of your home.
    Throughout the video, we'll provide a side-by-side comparison of the before and after installation, highlighting the transformative effects of a correctly installed vent pipe. Additionally, we'll introduce you to two different reliable brands of water heater vent pipes, allowing you to choose the one that suits your needs best.
    One crucial aspect we'll address is the installation of essential components such as the storm collar and roof vent cap. These play a vital role in safeguarding your home and preventing any potential issues that can arise from improper installation.
    We'll delve into a common problem faced by many homeowners in Houston, TX, and the surrounding areas-the incorrect installation of water heater and furnace flue pipes. We'll shed light on the hazards these installations can pose and explain why it is crucial to address them promptly. From personal experiences, we have encountered numerous homes where the natural gas flue pipes for water heaters in attics, garages, and closets had to be replaced. If you take a drive around Houston, TX, you'll notice this issue prevalent in many homes, even though most homeowners remain unaware of the dangers associated with it. From the risk of fire to carbon monoxide poisoning and potential damage to the water heater, we'll explain the severity of these hazards.
    To ensure a successful installation, we recommend using Amerivent brand water heater vent pipe parts. The list of essential components includes:
    1 x 3" Vent Cap
    1 x 3" Storm Collar
    1 x 3" Vent Pipe Shield
    The 3" vent pipe lengths are available in various sizes, accommodating different installation requirements. Choose from options such as 12", 24", 3', 5', 6', or 8' lengths, depending on your specific setup.
    Join us in this step-by-step tutorial as we guide you through the proper installation of a natural gas vent pipe for your water heater. Enhance the safety of your home, eliminate potential hazards, and gain a comprehensive understanding of the importance of correct venting. Don't forget to support our channel by using the provided link for any purchases you make. Thank you for watching, and we look forward to helping you improve your home's safety!
    Subscribe to our channel for more insightful videos on home improvement, repairs, and maintenance.
    #theartofplumbing #waterheaterventpiping #howtoventagaswaterheater #howtoplumbing #plumber #plumbing #40gallongaswaterheater #waterheatercap #waterheaterventhood #fluepipe #waterheater
    Mailing Address
    Claude Taylor
    B.O. Box 1251
    New Waverly, TX 77358
    plumberx1@gmail.com

КОМЕНТАРІ • 50

  • @williamdyckman9704
    @williamdyckman9704 4 роки тому +9

    Claude, very informative video on how to install vent flue pipe. Thanks, for making !!

  • @davidshettlesworth1442
    @davidshettlesworth1442 Рік тому +1

    Thank you for an excellent video. Well done on the fix of the wood roof touching the vent pipe. I love my "Saws-All" and the clearing of previous bad work. Carry On!

  • @lawsonharrison6927
    @lawsonharrison6927 4 роки тому +2

    You helped me prevent a potentially disastrous mistake. Thanks bud!!

  • @karrenger1
    @karrenger1 3 роки тому +1

    couldn’t find a video on this anywhere, thanks for the help

  • @ShawnMtz_78
    @ShawnMtz_78 3 роки тому +2

    Thank you in now looking forward to installing my vents...people let's not forget to "adhesive" these things as well...

  • @cwitham69
    @cwitham69 4 роки тому +4

    Thanks Claude, now I'm an expert too! 🤓 Hey about those tank water connections, there are no galvanic breaks at the tank. That wouldn't pass in Ohio...

  • @CNHInspections-CentralNebraska

    Good job... I like your videos. If you have time could you do a video on bonding CSST gas line in a house?

  • @Clappincardboard
    @Clappincardboard 7 місяців тому

    Great video. Very helpful.

    • @theartofplumbing
      @theartofplumbing  7 місяців тому

      Glad it was helpful! I appreciate your comment.

  • @mskytyn4290
    @mskytyn4290 3 роки тому +3

    Hi, my water heater is in the attic and there is a leak where the pipe meets the roof or the vent. Notice a stain on my ceiling now and insulation foam wet in attic. I don’t know who to call... roofer or plumber?

  • @cabrito1cabral
    @cabrito1cabral 3 роки тому +3

    Doe's it need to be high heat silicone calking?

  • @AlnT100
    @AlnT100 4 роки тому +4

    Where so I get that torch would make my life much easier with solder with that small flame

  • @markkrenisky3203
    @markkrenisky3203 16 днів тому

    The flex vent was fine. It just can’t pass through the ceiling. The single wall was definitely wrong though. Needs to be B vent through ceiling and roof with at least 1 inch clearance to combustibles.

  • @wayneschlotfeldt1631
    @wayneschlotfeldt1631 3 роки тому

    Great video. Thanks

  • @joseartiaga3048
    @joseartiaga3048 4 роки тому +1

    Great video

  •  3 роки тому

    Nice job

  • @dman7425
    @dman7425 Рік тому

    Nice fix

  • @a_life_painted_with_color
    @a_life_painted_with_color Рік тому

    There's gotta be a better option to the escutcheon plate you put around the vent going through the ceiling drywall, at the end of your video here. I've got a big AC leak from the little crack around my vent pipe going through the ceiling. Someone should make a collar with an air tight/heat isolating silicone escutcheon that stops air coming from the attic.

  • @edwardlepage3207
    @edwardlepage3207 4 роки тому

    Very professional job, I have one question, do you have to use high temp. silicone around the vent pipe because of the heat?

    • @tomatexelon
      @tomatexelon 4 роки тому

      He used the wrong stuff for that application

    • @MrDmadness
      @MrDmadness 3 роки тому +1

      Yes, b vent cl3arance is 1" to combustibles, thisninckudes the roof tar or silicone you use since its combustible. It also needs to extend 2 feet higher than any roof portion within 10 feet.. depending on where you live and local codes, the 2 over 10 rule is fairly standard.

  • @drumdrum36
    @drumdrum36 4 роки тому +1

    How hot should the backdraft pipe be getting?

  • @1weirddoe571
    @1weirddoe571 4 роки тому +2

    I have a piece of that flexible vent from Menards and it says clearance 1 in.

    • @theartofplumbing
      @theartofplumbing  4 роки тому +2

      Cool 😎 that's right.

    • @1weirddoe571
      @1weirddoe571 4 роки тому

      @@theartofplumbing, oh yeah so I just checked it again and you're right since it says you can't put it through walls and stuff ceilings...

    • @1weirddoe571
      @1weirddoe571 4 роки тому

      @@theartofplumbing, please explain in a video why I can't used my old 3" B-vent, going 30 feet up out the top of the roof, and vent my power vent water heater 2" snorkeled to that. I don't see what the problem is whatsoever--so what if there's condensation, there's condensation with the normal gravity vent water heater that I have side by side. So I'm testing them both out in case one of the other goes out but I won't use them both at the same time-- unless you think there's some thing I don't know and that I can use a gravity and a power vent together but I haven't figured that part out yet quite yet.

    • @theartofplumbing
      @theartofplumbing  4 роки тому +2

      Really? Interesting.

    • @1weirddoe571
      @1weirddoe571 4 роки тому

      Continuing my Q: Even though it's a code fail, have you a video on PowerVent water heater into type B, double wall Amerivent? Cat 1 venting rules not for PowerVent water heaters--not classified type 1, so they are type 4? I tried it yesterday and it worked fine. Won't there be just as much condensation as my gravity water heater--so what's the big deal? Why should I have to convert 3" Amerivent B to 2" PVC to run a PowerVent? The PowerVent water heater is just my backup to my gravity water heater and I don't think I will run them at the same time, because they are two different categories--or can I? PowerVent will blow out the pilot on the gravity heater? Have you seen anything like that before--where the power vent water heater actually snuffed out the pilot light on the gravity water heater if they are both vented together? Good video?

  • @miguelalvarado2410
    @miguelalvarado2410 10 місяців тому +1

    wouldn't the silicon melt with the heat?

  • @SGDeGalvez
    @SGDeGalvez Рік тому

    I just put a water heater in and the vent ducting is very hot. Is that normal? It wont light a tissue on fire but I cant rest my hand on it.

    • @theartofplumbing
      @theartofplumbing  Рік тому +1

      That's normal

    • @SGDeGalvez
      @SGDeGalvez Рік тому +1

      @@theartofplumbing thanks! its just warm now. appreciate the video.

  • @zealthsteel7542
    @zealthsteel7542 4 роки тому

    He there is a plumbing Co advertising on your comechaile site