Power Factor என்றால் என்ன? பராமரிப்பு செய்வது எப்படி?
Вставка
- Опубліковано 5 жов 2024
- plc,#training,#plc,#electricalengineering ,#training,#trainingcourses electrician training,electrical courses,electrician courses,#electricalcalculation
📚📚📚📚📚📚📚📚
Paid Training Course & Electrical Guidelines Available
1. Industrial Automation course ||PLC||HMI
2.PLC Beginners Course
3.Electrical & Mechanical - Handbooks - 200+ Books
6.Electrical Schematics Reading Training Course||Tamil||English With Subtitles
7.The Complete Electrical Power Control and Protection ||Eng With Subtitles
8.The Complete Hydraulic & Pnumatic Training Course
9.Electrical Calculations Pro(Android App)
10.Electrical Study (Android App)
11.Electrical Wiring Book
12.VFD - Variable Frequency Drive - Training Course (4hours Duration)||English
13.Automation Studio V7.0 || Training Course
Electrical Training Course Catalogue
wa.me/c/918838...
👆👆👆👆👆
If u Wants Message
Electrical Info
WhatsApp Number Msg
+918838515341
wa.me/message/...
Or
What's Up Call : +918838515341
Contact Us
Email :electricalinfo.ta@gmail.com
Official Site : www electrical4info.com
The power factor (PF) of an electrical system is a dimensionless number that reflects the efficiency of how electrical power is being utilized. It is defined as the ratio of real power (P) to apparent power (S) in an AC circuit. Mathematically, power factor is represented as:
Power Factor (PF) = P / S
Where: P = Real Power (measured in watts) S = Apparent Power (measured in volt-amperes)
The power factor ranges between 0 and 1, where 0 represents a purely reactive circuit (all power is reactive, and no useful work is being done), and 1 represents a purely resistive circuit (no reactive power, all power is used to perform useful work).
A high power factor (close to 1) indicates that the electrical system is operating efficiently, with less reactive power and reduced energy losses. On the other hand, a low power factor (close to 0) indicates poor efficiency, leading to higher energy consumption, increased electricity bills, and potential strain on the power distribution infrastructure.
Maintenance Procedure for Power Factor Correction:
Maintaining a high power factor is essential to ensure energy efficiency and optimize electrical power consumption. Power factor correction (PFC) is the process of improving the power factor by reducing the reactive power in the system. This is usually achieved by using power factor correction equipment, such as capacitors.
Here are the steps involved in the maintenance procedure for power factor correction:
Power Factor Assessment: The first step is to assess the power factor of the electrical system. This can be done using power quality analyzers or meters that can measure the real power, apparent power, and power factor.
Identify Reactive Loads: Identify the electrical equipment and components in the system that are causing reactive power consumption. Typically, inductive loads such as motors, transformers, and fluorescent lighting are the main contributors to low power factor.
Determine Required Capacitance: Calculate the required capacitance for power factor correction based on the reactive power measurement. This can be done using power factor correction formulas and engineering calculations.
Install Capacitors: Install appropriately sized power factor correction capacitors at strategic locations in the electrical system to offset the reactive power generated by inductive loads. Capacitors act as reactive power generators and help to improve the power factor closer to unity.
Regular Maintenance: Perform regular maintenance checks to ensure that the power factor correction equipment, such as capacitors, is functioning correctly. Check for any signs of damage or degradation and replace faulty components as needed.
Monitor Power Factor: Continuously monitor the power factor to ensure that it remains at an acceptable level. If there are any significant changes in the electrical system or additional loads, reevaluate the power factor and make necessary adjustments.
Optimize System Design: When designing new electrical systems or upgrading existing ones, consider power factor correction from the beginning. Proper load balancing, selecting energy-efficient equipment, and using power factor correction devices from the outset can significantly improve energy efficiency.
By maintaining a high power factor, businesses and industries can reduce energy wastage, lower electricity costs, and contribute to a more sustainable and stable electrical grid. It is essential to conduct regular maintenance and implement power factor correction measures to maximize electrical system efficiency and minimize environmental impact.
📚📚📚📚📚📚📚📚
Paid Training Course & Electrical Guidelines Available
1. Industrial Automation course ||PLC||HMI
2.PLC Beginners Course
3.Electrical & Mechanical - Handbooks - 200+ Books
4.Electrical Notes || Practical Guidelines || Standards
5.Electrical Calculation|| Excel Sheet
6.Electrical Schematics Reading Training Course||Tamil||English With Subtitles
7.The Complete Electrical Power Control and Protection ||Eng With Subtitles
8.The Complete Hydraulic & Pnumatic Training Course
9.Electrical Calculations Pro(Android App)
10.Electrical Study (Android App)
11.Electrical Wiring Book
12.VFD - Variable Frequency Drive - Training Course (4hours Duration)||English
13.Automation Studio V7.0 || Training Course
Electrical Training Course Catalogue
wa.me/c/918838515341
👆👆👆👆👆
If u Wants Message
Electrical Info
WhatsApp Number Msg
+918838515341
wa.me/message/HTHJQG25J25BJ1
Or
What's Up Call : +918838515341
Contact Us
Email :electricalinfo.ta@gmail.com
Very good explanation for beginners like me
Usefull information sir
Sir super Nice Beautiful very nice explanation
Good explanation sir 👌👌👌
Capacitor conactor advantages and energy meter basic parameter பத்தி சொல்லுங்க sir
Very nice explanation bro😊
❤❤❤❤ romba nandri na😢❤❤❤❤❤❤❤
Nantri ayya ❤
Thank you bro
Sir capactior already stored current and voltage eg battery system type whenever need it give
26:33
A grade licence applying formet explain sir
Nice bro
EA licence applying qualification formet explain sir
Vanakkam bro
Bro en industry la . Neraya motors vera vera HP la irukku . Athukku ellam sethu orey capator ah vaikalama bro
I don't understand
@@electricalinfo-tamil sir .ennoda industry la irukkura motors ku thani thani ah capacitor vaangi vaikkirey (e.g : 3 hp motor 1kvar , 15 hp motor 5kvar , 10 hp motor 4kvar ) ithukku naa mothama EB meter ku next ye orey 10kvar capacitor vaikkalama bro .
Please sollunga sir
@gowthamsundar5455 electrical4info.blogspot.com
Kindly visit free guide line... need to check calculation
Good explanation 😊
Superb bro.
Usefull information sir