Поділитися
Вставка
  • Опубліковано 6 січ 2025

КОМЕНТАРІ • 253

  • @martindeblois6952
    @martindeblois6952 Рік тому +14

    Use your experience to repair an expensive digital caliper. Turns out the seal around the case had been misplaced in the plastic die cast seat. After dusting off and a clean install, display is back to life! THank you for the tip!

  • @steve8395
    @steve8395 Місяць тому +7

    I was a technician on the line that built those meters. Your video brought back some fond yet frustrating memories. Those little tabs braking and misaligning the switch were common issues in manufacturing.

    • @John-Nel
      @John-Nel Місяць тому

      That must be because of low quality and / or recycled material being used.

  • @artysanmobile
    @artysanmobile Місяць тому +4

    The Fluke 80 series meters are spectacularly reliable. They make the argument for spending more for tools instead of spending again. My 87 is 36 years old, virtually all in the field. At one point, Fluke became aware of a problem that mine did not even have and sent me an entire kit of parts and directions to repair it. Satisfaction!

    • @railgap
      @railgap Місяць тому

      I had a 70 series until it got stolen, dropped it off ladders, left it on hot machines, blew its fuses. Never had a lick of trouble with it until it got stolen with the rest of my tool kit. Family bought me whatever 80 series I have no, I've had it at least 20 years, tho it receives a bit less abuse now that I'm retired and also not running haunted house attractions in my spare time. ;) Never had a segment go dead or any other malfunction.

  • @VelcroElGato
    @VelcroElGato 2 місяці тому +30

    Back in the 1980s I owned a manufacturing business making silicone connector strips. Zebra was my competitor. They always made an inferior and cheaper product. The deflection design is critical to the assembly from the display to the circuit board(s). Few manufacturers understood how to use such connectors for reliable performance. I provided holders along with my connectors and assisted with design in reliability. No one gives a shit about doing the right thing these days. It is all deiven by greed, not pride and reliability. Thank you China.

    • @spvillano
      @spvillano 2 місяці тому +2

      It all comes down to quality of components for anisotropic connectors and the slightly older subclass of elastomeric connectors and the board contacts/display contacts.
      Of course, cheaper is better to many, which holds down the costs, but also limits the lifetime of the product.
      I don't blame China because someone wants a $20 meter, rather than a $200 meter, as China didn't invent the market they're catering to, the buyers create that market.
      My first experience with these connectors and failure modes was with my old Beckman 310, where the plastic clips stretched, allowing oxidation to interfere with the display connections. Fortunately, the Fluke 77 had entered the market around when I was tiring of fixing the meter repeatedly.

    • @billdivine9501
      @billdivine9501 Місяць тому +3

      What did you do with your business?

    • @billdivine9501
      @billdivine9501 Місяць тому +2

      @@spvillanomy first job as a technician at a defense contractor the company had a couple Beckmans and a Fluke 75. Not enough meters for the techs though. Very frustrating. I loved the Fluke. So much so that I bought a 75 in 1989 or so for I think $119. Still have it and the box it came in. Still works, made in USA. Got in trouble for bringing it into work because it didn’t have calibration stickers on it and it wasn’t property of the company.

    • @Foxbat1155
      @Foxbat1155 Місяць тому

      Thank the immigration act 1965 that replaced your people for outsiders

    • @spvillano
      @spvillano Місяць тому

      @@billdivine9501 we had a fairly decent spif on the 70 series when they were introduced and I was working sales at an electronics components and equipment wholesaler. Never sold a meter, I put our counter sample meter into a tech's hands with a few resistors and batteries, the meter sold itself.
      The company owner, notoriously cheap, complained how the meter was now used and he'd lose money - then he saw the sales figures and shut up. Made a sizable increase in my paycheck, but I sold nothing, the meters sold themselves.
      Bought two, one suffered water damage and the other's switch failed and shredded itself. Miss those workhorses though!

  • @JimLambier
    @JimLambier 2 місяці тому +12

    I used to manage a business that manufactured electronic equipment and we all had Fluke meters. I honestly can say that I never encountered a problem with their LCDs. Unfortunately, our corporate overlords decided to get into the multimeter business and started to sell rebranded meters from China. We were no longer allowed to have the Fluke meters. The rebranded meters were junk. They were inaccurate, killed batteries quickly and had displays that flaked out like what you showed. To 'comply' we kept using the Fluke meters but whenever we had corporate visitors, I would collect the Fluke meters and the guys would display the junk meters on their bench. When the visitors left, they got the Flukes back.

    • @railgap
      @railgap Місяць тому

      If you know, you know. :D I've lived similar stories.

  • @jackwalker4887
    @jackwalker4887 2 роки тому +8

    Surprisingly easy fix, in fact for me just opening the case and fastening the screws was enough! Who knew. This saved my small kitchen clock and made my day (surprising how hard it is to find a small unobtrusive battery powered radio controlled clock that reliably shows the time and nothing else). Thank you so much!

  • @artysanmobile
    @artysanmobile Місяць тому +2

    The other 30% in 70% rubbing alcohol is water, the very last thing you want to leave behind. Either remove it carefully and completely or use 100%. It can be hard to find in a container but individual foil packets are readily found in electronics or photo supplies. It makes all the difference in the long run. Thanks for your excellent demo.

  • @TheGordy1950
    @TheGordy1950 9 років тому +13

    Those Zebra strips have always been a problem. What you did was the proper way to correct the problem. Some people will even go a little too far and take the Zebra strips off the LCD display which is a big mistake. Oils from handling Zebra strips can cause all kinds of problems. I used to replace them on all kinds of test equipment and learned the hard way.

  • @trhosking
    @trhosking Місяць тому +1

    Some graphite from a 4B pencil does a wonderful job of restoring conductivity on those contacts after giving them a good clean.

  • @100nortonfan
    @100nortonfan 8 років тому +10

    Just to thank you for posting this repair video. My Fluke 77 had the same issues, and I cleaned the LCD circuit board contacts as you've indicated. Presto! This cleared the issues up completely! Thanks!

  • @coryroberts8910
    @coryroberts8910 6 років тому +8

    Thank you! This helped save my Oxo kitchen scale by visualizing the issue. The LCD was display just like the in the video. The design was different, this used a ribbon cable (not the clip in kind). I squeezed it into the circuit board and the display worked great. To fix the issue, I placed a thin piece of plastic so that it would increase the pressure by a little bit, enough that the display is now perfect.

  • @rennethjarrett4580
    @rennethjarrett4580 Місяць тому +1

    Just a few weeks back I found this old R S Micronta digital meter. I'm not sure how I got, but I think it was a defective one someone gave me years ago. I thought OK fix it or throw it out. I have to much stuff and much of it is not longer of use or is junk. So I opened it up and put batteries in it and nothing happened when I turned it on. Dead I thought. So I looked at the insides to see if there was anything on the board worth saving. Somehow in that process when I pulled the board off I noticed that the display panel was not attached with any wires. Weird, I thought, then I saw where contacted the board. Hum, those metal parts in there look like they are tarnished. I cleaned them, and put the batteries back in and the display worked fine. so I have another volt/ohm meter. Sadly, I have trashed several meters in the past due to the display issues. Your video here now confirms what I found out. This is a new type of connection for me. In the case of this current meter, it was in my junk collection I bet more then 20 years. So that alone will have these things tarnish and stop working now that I found this new connection issue. Now for test leads that will last longer and still flexible.

  • @ruthreebel9079
    @ruthreebel9079 3 роки тому +3

    My contacts were slightly different than yours but I followed your logic and actually fixed 95% of my screen! Thank you so much.

  • @srinivasandevarajan9772
    @srinivasandevarajan9772 Рік тому +1

    Thanks a lot, we have the same LCD issue with Casio DQ - 750F Digital clock and we did a alcohol cleaning on BUS from LCD to PCB and it did worked.

  • @michaeldoak4678
    @michaeldoak4678 4 роки тому +6

    WOW My fluke 83 has been doing that for about 4 years and its 25 years old. So I asked a question why does it have this problem. In the time it took to watch this video I had it fixed. I can't thank you enough thank you thank you thank you!

  • @colinpovey2904
    @colinpovey2904 10 років тому +2

    Thanks to your video, I was able to repair my Fluke 85. Display is better now than it was 20 years ago.

  • @daisyv2110
    @daisyv2110 3 роки тому +2

    Thank you for this video, I was able to fix my 9-year old digital scale. Followed your instructions to wipe the connectors with alcohol and now the lcd display is as good as new.

  • @james67693
    @james67693 2 місяці тому +1

    Cleaning the contacts with alcohol is good; but then, a very thin coat of silicon grease should be applied to prevent future micro contact corrosion problems. This has served me well thru the years for long term electronic fixes.

  • @marridesign4108
    @marridesign4108 11 місяців тому +1

    Thanks so much! You just fixed my jewelry scale just cleaning the adhesive and adding electrical tape. Genius!

  • @LostinMND
    @LostinMND 11 років тому +19

    I use one of those pencil eraser to clean the contacts first and then I use acetone to clean them. I also clean the ends of the contact strip with acetone and air blast everything clean and dry. Fixes it right up.

  • @KiwiGran1
    @KiwiGran1 7 років тому +23

    I fixed the broken LCD display on my alarm clock by heating it with a hair dryer and then giving it few taps with my knuckles. Completely restored now.

    • @stuartracing1
      @stuartracing1 3 роки тому +3

      Gonna try this one on my motorcycle....

    • @Tom-bf6nm
      @Tom-bf6nm 3 роки тому +3

      @@stuartracing1 How did that go, Paul?

    • @stuartracing1
      @stuartracing1 3 роки тому +2

      @@Tom-bf6nm I didn't get any change.. I wish I did,but nothing...

  • @rodneyjackson622
    @rodneyjackson622 9 років тому +7

    I am so happy, You have taught me how to fix or repaired my Fluke 87 multimeter, I am so please. My digital display is showing , just like new. You is a great teacher. Thank you very much.

  • @StogieBill
    @StogieBill 7 років тому +12

    Really well put together Eric. I like the way you fast forward through the boring bits (that other people make us watch) and get right to the essential points. A good learning experience.

  • @barrykelleher4735
    @barrykelleher4735 10 років тому +3

    Superb instructions. I followed step by step with a Fluke Automotive (Fluke 88) and it has restored it perfectly

    • @ElectronicTonic156
      @ElectronicTonic156  10 років тому

      Glad to help.

    • @sadfur8728
      @sadfur8728 Рік тому

      Did Fluke have a lifetime warranty on their meters a while back when they were more premium? Is that no longer offered because the construction quality has been revised for affordability?

  • @GSMSecure
    @GSMSecure 5 років тому +3

    Just followed your video and was just about to dispose of my FLUKE 73 III
    It worked brilliantly so thank you for taking the time to help others.
    I now have a brand new meter ;)

  • @onrivertime
    @onrivertime 7 років тому +3

    It worked - Thanks! I looked at three different videos and each showed a different method (alcohol, silver conductive grease & buying aftermarket connectors) - might as well start with the easiest and see what happens. Glad to have the display back on my 27 year old Fluke 87.

  • @rwtyler
    @rwtyler 8 років тому +3

    Thanks for the info. I have a Fluke 87 that has been tucked away for about 8 years because of the ghost numbers on the LCD. I always figured it needed a new LCD so I used another meter. Came across your video, gave it a try and brought the LCD back to life. Now I can use the Fluke 87 again. Easy to do and a cheep fix for an expensive meter.

  • @DrivelineMaster
    @DrivelineMaster Рік тому

    I also use contact cleaner on the pink contact pad that makes contact with the circuit board. It's very amazing how sensitive those LCD's are to a minute amount of voltage drop.

  • @G5Ckxew
    @G5Ckxew 7 років тому +93

    alcohol.... the solution to all of life's problems

    • @ferndog1461
      @ferndog1461 4 роки тому

      Hobbyists can get 99% Alcohol from Amazon. Pure acetone can be used to clean connections or left over flux.

    • @aracon9721
      @aracon9721 3 роки тому +4

      The cause of, and solution to, all of life’s problems - Homer Simpson

    • @microtacc
      @microtacc Місяць тому

      @TqSNv9R0iG5Ckxew 💪😁👍

  • @greg9198
    @greg9198 4 роки тому +3

    Thank you so much Eric! I managed to fix my watch's LCD that somehow popped out of its plastic latch. As its was my first watch from many years ago, it means a lot to have it up and running again.

  • @fins59
    @fins59 5 місяців тому +3

    Good video, no time wasting and contains usefull information, liked & subscribed.

  • @garyjeffersii6735
    @garyjeffersii6735 3 роки тому +3

    Thanks much for this. I ended up lightly scraping the contacts with a precision flathead screwdriver and all segments came back.

    • @ThisOldMan-ya472
      @ThisOldMan-ya472 2 місяці тому

      A fiberglass tip electronic contact pen works better than a screwdriver.

  • @georgenicholas5210
    @georgenicholas5210 4 роки тому +7

    Nice job, one minor suggestion. I avoid 70% isopropyl. Use denatured, or at minimum 90%. It leaves less residue than 70.

  • @patrickgregory2826
    @patrickgregory2826 Місяць тому

    I have an old clock radio with this problem. So - I tried cleaning the contacts just like you - It Worked!

  • @JustSayN2O
    @JustSayN2O 2 місяці тому

    The wall-mounted control unit of my swimming pool's salt cell / chlorine generator has one malfunctioning LCD segment. New units cost north of $1k. I will attempt this repair. First I will buy some of the Caig Labs Deoxit that others here recommend. Thank you for the suggestion.

  • @user-rs8zg8ey2b
    @user-rs8zg8ey2b Місяць тому

    A pink eraser on the PCB contacts, then clean with alcohol has worked wonders on almost all contacts like, switches, pots, mech encoders, TV remotes, etc. also, clean them rubber/carbon push buttons on the fluke with just alcohol.

  • @rcari0687
    @rcari0687 4 роки тому

    Thank you so much, I had that problem for a few months now and lately I was getting frustrated with it that I thought of throwing it in the garbage and buy another one even though they are pricey, thank you again so much😀😀👍👍👍

  • @spooktasticaparanormal
    @spooktasticaparanormal 3 роки тому +1

    I have the same issue with a cb radio but the practical application is exactly the same. Thanks for sharing this video. Kind regards. Paul.

  • @ianhopkins8076
    @ianhopkins8076 4 роки тому

    had one of these fluke 85 with a issue with screen for over 30 year and 5 min after watching your video its fix thank you

  • @arthouston7361
    @arthouston7361 Місяць тому

    An alternative to the alcohol is the small eraser on the end of a pencil. It cleans up those contacts very nicely.

  • @arthurc3012
    @arthurc3012 Місяць тому

    Back in the 80’s when I was a.bench tech, we used “soft” rubber erasers to clean contacts. Any loose rubber could be brushed/blown off and there was no moisture or chemical residue.

  • @marciodeamorim8472
    @marciodeamorim8472 7 років тому +11

    Hey man, thank you very much for helping! I'm not fluent in english so my daughter is helping me, but your video helped lots!

    • @carlitosredsky
      @carlitosredsky 4 роки тому

      I know a little of English language, because in my work I have to Know English
      and French Languages, but I understand your problem, cause I also have sometimes problems with technical words! Then I used to go to the "configurations": in the "right corner of the video Image", click on the "wheel" and after the opening of the "new image", select "legends", click on it and there you have a new "image" with: all the word translation languages, where you can choose your preferred language. I hope have helped you a little, Marcio Amorim Rego !
      An embrace from: carlitos

  • @DrNickBailey
    @DrNickBailey 3 роки тому +1

    I have exactly the same issue with my multimeter and thought all was lost, but no! Thanks for the tip.

  • @MervynPartin
    @MervynPartin Місяць тому

    I wish that I had seen this video years ago. I junked my Fluke multimeter because of missing display segments. It had been my favourite meter.

  • @transcanada9028
    @transcanada9028 Рік тому +2

    I find with the zebra strips on LCD displays and carbon contacts in remote controls it's always better to use methyl hydrate then rubbing alcohol though it did work well for you and that's great. Also you might try 99% instead of 70% alcohol. Looks good though.

  • @BeleefmeemetJP-vd6ly
    @BeleefmeemetJP-vd6ly 2 місяці тому

    Nice, fixed my (new out of the box) hygrometer by cleaning the contacts: rubbers, screen and print. Using your tips, cottontips and contactspray instead of isopropanol. Thanks for this 10yo video.

  • @chilo31416
    @chilo31416 7 років тому +4

    My fluke 87 was saved by this video. Thank you uploader, for sharing this video.

  • @peccantis
    @peccantis 3 роки тому

    Thank you! Fixed the display on my fish scales with this. Adding a bit of sponge on the back of the display works well to keep it flush to the screen.

  • @sirajhussain791
    @sirajhussain791 3 роки тому +1

    Excellent. I am having same problem in my Fluke 87

  • @CookyMonzta
    @CookyMonzta 3 роки тому +1

    Excellent! I hope I can fix my pedometers for my stationary bike. The digits are completely screwed up.

  • @Timmmmm14
    @Timmmmm14 10 років тому +11

    Works like a charm. ALSO I'm sorry you broke off one of your little retaining clips (in your video) But that too was instructive and cautioned me to be watchful because I may have done the same thing as well as being mindful to orient the mode selecting rotary switch during reassembly, So let that be a lesson to would be posters in a "how to video" that your "mistakes can be equally informative and should not be "edited" out Great job and thanks for saving me money and frustration TIM

    • @RetroGameModz
      @RetroGameModz 10 років тому

      Totally agree! It's probably not too uncommon for people who are making videos like this to edit out all the little mistakes, simply because they have too much pride to include the mistakes in their videos. But just as we can learn from our own mistakes, we can also learn from other people's mistakes as long as they are being presented to us.

  • @aday1637
    @aday1637 Місяць тому

    I've got a multimeter with the same issue that I still use but have to deal with the missing portions of the numbers each time I use it. I'll have to take a look see at this solution. Thanks.

  • @Szmeterlog
    @Szmeterlog Рік тому

    Thank you for making that video. I could finally fix the display of my kitchen scale I really depend on!

  • @joostparent3774
    @joostparent3774 2 місяці тому +1

    I have calibrated over a thousand Fluke 85s in the air force. Never found one off-spec. Found 1 with a broken fuse. And a hand full of display issues such as the one you describe here in this video. I used some alcohol as well and this worked very well for me. Fluke 85 is a very reliable high quality Multimeter. But with basic functionality. Absolutely love them.

  • @JamieHutchinsonTechUK
    @JamieHutchinsonTechUK 2 роки тому +1

    Worked for me nicely on my poorly designed exercise bike LCD screen, thank you! :)

  • @jeffchen1180
    @jeffchen1180 7 років тому +2

    Thanks for putting this up ! I have a fluke 88 that was doing the exact same thing and the cleaning of the contacts fixed it.

  • @douglas2lee929
    @douglas2lee929 2 роки тому

    Nice. You got lucky. The process of cleaning the zebra's and solder pad surfaces is always a crapshoot. Sometimes it works, sometimes it doesn't. So, you won this time. The amount of pressure against the strip is CRITICAL. Can't be too much, can't be too little. Sometimes the strips deform slightly or "shrink" slightly over the years, which can be enough to cause them to loose good contact. Even a few thousandths of an inch of dimensional change is enough for them to not work. So the shimming approach does sometimes work (but use only a TINY amount of shimming. If there is too much, the strip will get "squeezed" too much when reassembly, causing deformation, and the same poor contact problem). By the way, although Fluke no longer sells replacement strips (the woman in Service Parts actually laughed at me when I called--"Sir, your meter is 28 years old, we don't have parts for it anymore"), the strips for SOME models of Fluke DMM's are available from one or two places on the Net if you search hard enough. I bought a few for my 87's a few years back. Heartbreaking to consider trashing a $400 (more now) meter because of 20 bucks worth of silicone. Best wishes.

  • @rabidfarmer9765
    @rabidfarmer9765 Рік тому +1

    Thanks so much - this gave me hope on an old machine.

  • @5hawks
    @5hawks 10 років тому

    Just replaced the "elastomeric strips" in my Fluke 77 after 30 years due to missing character segments in the display but that wasn't the fix. One of the PCB solder connections to the elastomer strips had rotten lead which didn't respond to contact cleaner. Scraped it with an Exacto knife then more cleaner. Works good now. Save your money and remove the 4 screws holding the LCD tower ass'y so you can examine the PCB contacts and clean them. If that doesn't help then try new strips.

  • @davecrabbe4579
    @davecrabbe4579 Місяць тому

    Nice video.. that system that Fluke and others (LEGO NXT) went to for their displays destroyed their product's lifespan. In my lab I had the generation of fluke meters before they switched to that PRESS carbon pad assembly and every single fluke meter failed within 5 years.. The old ones are still working 10 years later. Was same with Lego who used that system for their robot kits. Had 20 units.. every single one of them had to be replaced by LEGO within 3 years.

  • @TheRubbertube
    @TheRubbertube 8 років тому +1

    Just saved an old expensive Digital Vernier Caliper from the scrap heap using this method. Thanks.

  • @friedmule5403
    @friedmule5403 6 років тому +2

    A wary old and effective trick that are being used in the PC repair industri is to use the brown and blue ballpen eraser and some 90-95% Isopropyl-alcohol.

  • @aday1637
    @aday1637 Місяць тому

    My trusty old Beckman (now over 40 years old) still works fine. How do you suppose they were able to make a lasting digital display all the way back in the early 80's? Could it be they actually took the time to assemble them better? I do know when I purchased the meter (from Baynesville Electronics just north of Baltimore) the salesman told me the tested these by running over them with a truck and dropping them off a building to see if they survived. I own several other brands but when I want to be sure I always go back to the Beckman meter. The reliability is unparalleled. All digits are dark contrast on the background.

  • @rachrub
    @rachrub 4 роки тому

    Genius! Thanks to you I found a simple fix to my exercise bike speedometer. Many thanks!

  • @armandine2
    @armandine2 Рік тому +1

    just done my Fluke 73 - this must be one of the easiest wins in electronics. I had put if off for too long and it only takes 5 minutes. NB pcb screw under fat HRC fuse.

  • @hinspect
    @hinspect Місяць тому

    Gently with an eraser works well sometimes, I used to keep one in my box. (Old radio engineer in my late 20s in 1981)

  • @mechadrake
    @mechadrake 8 років тому

    couple years ago i fixed gearbox position (automatics -prnd321 thing) displays in my cars. for some reason it had zebra strips too, lcd like that could be with soldered wires, but no! still works (at least one shows proper gear, another car has offset position indicator for some reason now) , learned that from playing with some calculator doing things like in the beginning in the video.

  • @tsailor100
    @tsailor100 Місяць тому

    I have a top of the range Fluke (cost me a lot of money). The RMS function does not work. Instead of pumping a lot of money for repairs, I bought a Chinese equivalent for fraction of the cost with more features and the Fluke is just gathering dust.

  • @ClydeBoenke
    @ClydeBoenke Місяць тому

    Wow! Thanks. Fixed my old Fluke 79.

  • @4umata
    @4umata 6 років тому +2

    Fixed my old 7-segment clock thanks to this, much obliged good sir!

  • @caoimhin7122
    @caoimhin7122 2 місяці тому

    Use DeoxIT D5 instead of alcohol. DeoxIT D5 will remove the oxidation as well as the gunk. It will also help seal against further corrosion. I use it all the time on volume knobs on radios and the like. It works wonders at bringing radios with wonky volume knobs back to life. It works on anything electrical. It's safe for plastics as well.

  • @james67693
    @james67693 2 місяці тому

    ...and yes; the contact buttons will make contact thru the silicon grease...

  • @cainarnold1
    @cainarnold1 7 років тому

    Thanks for your help..... I used alcohol and cleaned up the strips really good and it all works perfect.
    Thanks again...

  • @snowman0129
    @snowman0129 Рік тому

    This works perfectly and very easy to do. Fixed my motorcycle digital cluster. Do not use a cotton swab, use a cotton shirt.

  • @MrkWil1234
    @MrkWil1234 7 місяців тому +3

    Pencil eraser is a great contact cleaner, especially for battery contacts.

  • @pibbles-a-plenty1105
    @pibbles-a-plenty1105 2 місяці тому

    If the circuit board zebra strip contact pads were gold plated there would be a lot less of the problem of fading LCD segments. But cheap is cheap. After cleaning BOTH the circuit board pads AND the zebra strip I apply Caig F5 Fader-Lube. Also with the push buttons. Works really well - my Fluke 77 and 23 multimeter displays stay reliable for much longer.

    • @JustSayN2O
      @JustSayN2O 2 місяці тому

      So it's not a fluke !

  • @rogerfraser15
    @rogerfraser15 10 років тому +2

    Thanks. Your video helped me bring back my FLUKE87 display. Thanks again!!!

  • @bik3much
    @bik3much 6 років тому +1

    Very helpful! Cleaned mine with alcohol on both the board and spongy pad and it made the segments stronger; less faint!

  • @tlapancovazquezguillermofr4869

    It worked very well for me, thank you

  • @jimseviltwin1
    @jimseviltwin1 Місяць тому

    I’ve had good success using spray contact cleaner to clean the contact points.

  • @AgressiveHouse
    @AgressiveHouse 5 років тому

    What about a problem when lcd contrast goes really bad when battery discharges a bit? All other functions work well, but you have to look at the lcd screen at an angle to see anything. Is it that the manufacturer saved on some components which should regulate the lcd screen contrast?

  • @stevenA44
    @stevenA44 6 років тому

    Interesting. I've got a few electronic devices that the same problem is going on. I'll have to try this. One of them is my Icom IC-735 HR rig. The very bottom of the display is blank.

  • @NiNjaTurtLe697
    @NiNjaTurtLe697 Рік тому +1

    I'm curious how the rubber strip comes into play to push allow display on lcd? Is there light shining through the rubber strip? Does the rubber strip have to be perfectly aligned with slots/holes on the strip? etc

    • @dronillon2578
      @dronillon2578 Рік тому +1

      There is no light. It is about electrical contact. The rubber is basically a conductor (the black stripes are conductive). The same could be achieved with a ribbon cable or a bunch of individual wires. Each segment of the display requires one wire, plus one more wire for the common ground (or rather common plus contact).

  • @DarkRedZane
    @DarkRedZane Рік тому

    Thank you. Cleaning its contacts worked with my digital watch. 👍

  • @markallen2536
    @markallen2536 2 місяці тому +2

    I clean with the alcohol first, then q_tip on some Caig Labs De-Oxit. You will likely never have the problem again.

  • @gerardkenny8882
    @gerardkenny8882 2 роки тому

    Cleaned and now it works again thanks for the video

  • @TechsScience
    @TechsScience 4 роки тому +1

    I had tried this hack with my multimeter but it never worked

  • @rayfiore7779
    @rayfiore7779 День тому

    a pencil eraser to clean the pcb contacts before the use of alcohol will also help if the contacts are arced

  • @ryugaknight
    @ryugaknight 5 років тому +2

    Thank you! You just saved me from having to buy a new LCD watch!

  • @civednoel1388
    @civednoel1388 8 років тому

    Great tips Mr. Eric! very useful and informative. I'll try that with my bushnell yardage pro 1000 where the middle digit is getting washed out.

  • @MarkBush-en5cz
    @MarkBush-en5cz Місяць тому +1

    Use 95% isopropyl for all electronic cleaning.

  • @chriscarter4100
    @chriscarter4100 4 роки тому

    Thanks Eric, fixed my Fluke 73 perfectly using your vid

  • @gregaravnik6957
    @gregaravnik6957 3 роки тому

    CONGRATULATIONS! 😍❤️💯👏🥇

  • @beyondthegrave89
    @beyondthegrave89 2 роки тому

    Awesome video, worked perfectly. 8sed a hair dryer instead of toaster and the screen is perfect again

  • @umbra700r
    @umbra700r 8 років тому

    just got one off eBay and that saved me money and a headache! thank you

  • @boris9331
    @boris9331 9 років тому

    Should the rubber strips be cleaned aswell, as I believe they have contacts too that link contact from the circuit board to ones on the LCD.... and should the LCD contacts be cleaned too?

  • @genekoroncz6547
    @genekoroncz6547 7 років тому

    trying this on my digital watch. didn't use a q-tip the first time. Two rows of segments are out.

  • @LawEnforcementIsOP
    @LawEnforcementIsOP 2 місяці тому

    It's probably less of a dirt issue as it is with Oxidation. DeOxit might work better if IPA doesn't fix the problem.

  • @bhaskarbanik6716
    @bhaskarbanik6716 4 роки тому

    Will use in BP monitor display... Same problem here

  • @petroskaneas1880
    @petroskaneas1880 4 роки тому

    perfect. what if the crystall screen broke .how to fix it?