  • @peterjenkins886
    @peterjenkins886 9 місяців тому +1

    can you guys do a video on common faults and a troubleshooting guide for common failure points or operator setup mistakes

    • @appliedadhesives2683
      @appliedadhesives2683  8 місяців тому

      Absolutely! We'll make sure to contact you when we have something up.

  • @peterjenkins886
    @peterjenkins886 9 місяців тому +1

    thank u guys

  • @skyler_jaynes
    @skyler_jaynes 9 днів тому

    What would cause the glue machine to shut down automatically?

  • @PangDoodmaak
    @PangDoodmaak 2 роки тому +1

    Let's talk about the inputs and outputs, where do i activate them so that they show on the operator screen? I have applied inputs via terminal 8 and 9 , 10 and 11 and my three outputs as it is in the manual, now where do i activate them?

    • @appliedadhesives2683
      @appliedadhesives2683  Рік тому

      To start off this can only be done on input #1.
      Input #1 is on pins 8 & 9. So you wire up either a plc output (parent machine) or the 24Vdc applicator activation signal to pins 8 & 9. This completes the electrical hookup.
      Power on the unit.
      Select operating parameters and go to location 30. Set parameter 30 to 10.
      Now go to parameter 24. Set this to the number of minutes you want to wait before the unit go’s into Stand-bye. Note to test but it at 1, side note I believe there is a 4 or 5 minutes default delay. So it may take 5 or 6 minutes to drop into stand-bye.
      If you have any further questions feel free to reach out to us at (833) 293-7278 or on our website www.appliedadhesives.com.

  • @bruceaustreng7535
    @bruceaustreng7535 Рік тому +1

    The green ✅ is not lighting up, so the machine will not start, what are some things I can do to get it started

    • @appliedadhesives2683
      @appliedadhesives2683  Рік тому

      Here is a list of reasons why the green check mark will not light.
      - Not up to set-point temperature on all zones. Call me - possible bad heating zone.
      - parameter # 4 has a long delay Programer (5 minutes is enough for a pneumatic pump. Ten minutes for a gear pump.
      - The green check-mark is flashing indicates that the parent machine his preventing this from staying on. One of the inputs is set to inhibit the pump from activating. Parameters 30 to 39.
      If you have any further questions feel free to reach out to us at (833) 293-7278 or on our website www.appliedadhesives.com.

  • @opunake4lyf
    @opunake4lyf Рік тому

    How do I install an external light to signal low glue level, I have changed parameters 40 to 4 but I don't get a signal out

    • @appliedadhesives2683
      @appliedadhesives2683  Рік тому

      Low level signal is a closed contact. They supply the signal. See manual - chapter 3 (the last 6 to 8 pages).

  • @wcioden
    @wcioden Рік тому +1

    How to change temperature from degF to degC?

    • @appliedadhesives2683
      @appliedadhesives2683  Рік тому

      Parameter 20 will allow you to change from F to C.

    • @barrydasilva1895
      @barrydasilva1895 28 днів тому

      How do I get to parameter 20 on messa 6 ?? Would like to change C to F

  • @ttv_slammer_bot0175
    @ttv_slammer_bot0175 Рік тому

    What the hottest you recommend me put the degrees f

    • @appliedadhesives2683
      @appliedadhesives2683  Рік тому

      This is a bit more nuanced. You can go up to 450°F. The common prongs are boron with a max temp of 390°F. To go higher you need Kalrez seals.

  • @radzio132
    @radzio132 Рік тому

    How can i change temperature in standby mode?

    • @appliedadhesives2683
      @appliedadhesives2683  Рік тому +1

      Standby - this is found in operating parameters. Default is 100F and this represents how much temperature is lowered from the operating setpoint.
      The parameter # is 23.
      The manual for Pro Blue & Dura Blue, at the end of chapter 3. This section goes through it.
      Lock out Tag out!!
      Safety first.
      First off the manual switch destinations and you may overlook something because of it. I’ll outline how to setup automatic Standby.
      To start off this can only be done on input #1.
      Input #1 is on pins 8 & 9. So you wire up either a plc output (parent machine) or the 24Vdc applicator activation signal to pins 8 & 9. This completes the electrical hookup.
      Power on the unit.
      Select operating parameters and go to location 30. Set parameter 30 to 10.
      Now go to parameter 24. Set this to the number of minutes you want to wait before the unit go’s into Stand-bye. Note to test but it at 1, side note I believe there is a 4 or 5 minutes default delay. So it may take 5 or 6 minutes to drop into stand-by.
      If you have any further questions feel free to reach out to us at (833) 293-7278 or on our website www.appliedadhesives.com.