Sir intha concept ah site la irunthu sonningana visual ah understand Panna easy ah irukum ....🙏
நன்றி.
அருமை sir
Spr sir clear explanation
Thank you for your detailed helpful and useful. You are my teacher sir. I am not civil student.
Nic information sir
Thx sir 🤞🏼
Hi sir, Would you Please do Video abt Gypsum Plaster for wall and ceiling work. Kindly explain its advantages ans its problems.
Sir i am waiting
parapet wall la equalla than rod cut panrom athil eappadi sir lapping panrathu next floor kku.
It's same for compression zone?
Sir columnku 50d ok but for beamku edhe tana..??
Footing development length (Ld=?)explain
Veetlil Ulla kadapa rack eppadi pannanum nu podunga sir
Sir iam arul dce complete your builders any work
Sir steel quantity in roof epdi sir edukurathu help pannunga sir
Total column 12. 10 columnla 4 rod iruku.but 2 column la 2 rod than iruku.balance 2 rod concreate ulla poitu.mela epdi building extend panrathu.pls answer sir.
வணக்கம் சார் கண்ணன்!!
Whatsapp ல் படம் அனுப்பியது நான் தான் Rod வளைந்து உள்ளது மற்றபடி நன்றாக உள்ளது
மழையால்
துரு பிடித்துள்ளது!? என்ன செய்யலாம் நன்றி
One new information from you thank you sir
லாப்பிங் செய்வதற்கு பதிலாக இரண்டு கம்பிகளையும் சேர்த்து வெல்டிங் அடிக்கலாமா?விளக்குங்கள்.
There is an vacancy for B.E Civil engineering
Sir. Nan oru Watter tank kattanum 5000 litter veanum. Ground la pillars pottu than. So eavlo sathurati. Kattanum please sollungka
1 cft volume equals 28 litres. Roughly 200 cft volume tank holds 5600 litres. 6' * 6' * 5' size tank volume is 180 cft, which is 5000 litre capacity
Sir As per your specification lapping is to be done below lintel in any floor because even 12mm rod requires 2 ft lapping and that too not at same height for all rods in a coloum .Am I correct sir? If not please give your comment for correction.Thanks for your videos.
yes sir
Can we weld the rod after we lapped the two bars(50D).
We can do. I would suggest you to check with your structural consultant
Please
Not joining lapping rod at.straigt .make king ?that is old method.its correct or wrong. I know shanmugam Architect during 1986 .He was consultant our project at Pudukkottai
That is correct sir.
@@HONEYBUILDERS Thank you sir
Welding of column lapping for 4*12 mm is good or not for 2 ft distance ( all four bar in same distance) only available above slab for 1st floor only house. Does welding reduce its strength. If ok, how much length does it need to welding
Welding can be done for 2 feet length.
@@HONEYBUILDERS thank you sir.
@@HONEYBUILDERS ground floor colum la 16 mm bar one feet tha balance eruku sir columm lapping
welding panalama sir
2 floor ku strong ha eruku ma sir
@@asfvlogs3165 pls consult with a structural consultant with your plan and existing structure