HOW TO PERFORM SLUMP CONE TEST & HOW TO ANALYZE THE SLUMP RESULTS

Поділитися
Вставка
  • Опубліковано 28 січ 2021
  • In this video you will understand how to do slump cone test and why we do slump cone test.
    HELLO CIVIL ENGINEERS,
    Understand the market and Corporate demand what exactly they need,
    We fulfil the gap between the unemployment and the Corporate needs,
    CIVILGURUJI, "CIVIL ENGINEERS TRAINING INSTITUTE"
    can be the solution for Civil Engineers, how to get jobs and career growth is the strategic plan, & it can be learnt.
    CIVILGURUJI provides you the OFFLINE & ONLINE Practical Based Learning
    In Offline Training course You Will Learn...
    1. Building Estimation
    2. Bar Bending Schedule
    3. Bar Bending Schedule Advanced
    4. Quantity Survey & Rate Analysis
    5.Billing Engineering
    6.Surveying
    7. Professional Auto Cad
    8. Revit Architecture
    9. ETABS
    10. MSP
    AutoCAD
    Revit
    Etabs
    Microsoft Project
    Microsoft office
    Building Estimation
    Estimation
    Quantity survey
    Rate analysis
    Bar bending schedule
    Billing
    reconciliation
    Price Escalation
    Site execution work
    Personality development
    Resume making
    #civilguruji​ #civilengineerstraininginstitute​ #practicalsitetraining​
    How do you calculate excavation for foundation | Complete Details with Calculation By civil Guruji
    Call For all Details:- 9111001234
    Practical Training course & Fee Detail:- • Video
    Get Site Practical Training :- Get Site Practical Training :- www.civilguruji.com/s/store/c...
    Our Branch Address :
    1.DELHI - NCR Civil Guruji - 25, gate no. 1, behind Kailash hospital knowledge park -1 Greater Noida (201308) Nearest Metro station : Pari Chowk.
    goo.gl/maps/a2TpSDCCGiRYxEb19​
    2.BHOPAL Civil Guruji :- At Hind convent school Naveen Nagar, Bhopal, Madhya Pradesh 462010
    maps.app.goo.gl/UhHyHpBzNJRYd...
    3.LUCKNOW Civil Guruji :- At Prayag public school Sandaulli Umarpur ,Near Juggaur railway station road, Lucknow 225003near goel tower,
    maps.app.goo.gl/bxWdfd36j9TTE...
    4. NAGPUR Civil Guruji :- Karma veer Dadasaheb Kannamwar Engineering College KDK College Rd, Opposite Telephone Exchange, Namangan, Nagpur, Maharashtra 440009
    maps.app.goo.gl/URejiAmmVSqjJ...
    Offline Practical training is helpful for students to find a job in the future. Practical training can increase students' interest in civil engineering.
    one of the major problems faced in engineering is the quality of education they receive while doing pursuing a program in an institute. Several engineering institutions that have been set up in the last two decades lack well-qualified faculty and important laboratory infrastructure. Civil engineering is being transformed from theory-heavy to practice-oriented program, which needs a constructive laboratory infrastructure, helping students carry out various experiments. A dearth of such infrastructure not only hampers the learning ability of students but also reduces their employment opportunities.
    Various job profiles post a civil engineering course requires the incumbent to communicate with multiple stakeholders unlike in the past when the communication in the early career of a civil engineer was limited to semi and unskilled workers. Lack of emphasis on soft skills training during their engineering program is posing a challenge to the graduates. Most civil engineering graduates start their career in the construction industry and feel that their current qualification would merely suffice for them to survive the competition. But they soon realize that construction industry needs much wider knowledge and skills than they learnt in classrooms. civil guruji civil engineering basic knowledge site visit
  • Наука та технологія

КОМЕНТАРІ • 42

  • @technicaladda7864
    @technicaladda7864 2 роки тому

    Nice video Bhaijan

  • @shivshankarsharma6325
    @shivshankarsharma6325 3 роки тому +4

    Congratulations for 150k subscribers 🎉🎊🎉🎊

  • @Abhisheksingh-il6lx
    @Abhisheksingh-il6lx Рік тому +12

    according to the latest IS code 1199 slump test should be performed in 3 layers and 25 time taping.

  • @inzemamulhaque2349
    @inzemamulhaque2349 8 місяців тому

    Great

  • @parthasarathidas7420
    @parthasarathidas7420 3 роки тому +2

    sir slump test pe konsi grade of concrete use karte hai and water cement ratio kitna dena partahai .....jo aapne video pe dikhaya ...

  • @er.civilsociety9222
    @er.civilsociety9222 3 роки тому +3

    Good morning bhaiyo

  • @pandurangbhise1901
    @pandurangbhise1901 3 роки тому

    What defect indicate shear slump and collapse slump

  • @sunnykumarmaddeshiya3230
    @sunnykumarmaddeshiya3230 3 роки тому

    Thankyou sir

    • @Civil_Guruji
      @Civil_Guruji  3 роки тому

      Welcome Sunny..... Keep Learning..... Keep Sharing

  • @pravinvaishnav2758
    @pravinvaishnav2758 3 роки тому +5

    Sir , how we can measure slum after removing cone & what we have to do if we didn't got sufficient slum reading according to ISCODE? on site

    • @fazalurrahman3983
      @fazalurrahman3983 3 роки тому +1

      You have talk to RMC plant or where the material mixing process in going on and tell thn to maintain the slump as pr given slump values

    • @pravinvaishnav2758
      @pravinvaishnav2758 3 роки тому

      @@fazalurrahman3983 so if slum are not match then we have to reject the RMC or we can do some else......

    • @fazalurrahman3983
      @fazalurrahman3983 3 роки тому

      You can tell thn to add admixture to maintain slump or slump difference is under 50mm instruct Miller driver to rotate material for 10 to 15mins the slump will reduce (ths is kind of adjustment on site)

  • @sangmadybath1979
    @sangmadybath1979 3 роки тому

    Sir I want to know how much to add sand stone and water for one package of cement for slabs pleas tell me detail I am not engineer students but I want to build own house.

  • @MuhammadAwais-vn2wr
    @MuhammadAwais-vn2wr 3 роки тому +3

    Dear, kindly mention the IS code please and ASTM or ASSTHO if possible. Above all this video is very quality vidoe. Really appriciated for your work

  • @ashwanikumarsharma1958
    @ashwanikumarsharma1958 2 роки тому

    Sir, pore sitting position me karana hota hai ya standing position me

  • @civilfactknowledgemissiong357
    @civilfactknowledgemissiong357 3 роки тому

    Mix design m40per videos banaye sir

  • @be-honestindian3054
    @be-honestindian3054 3 роки тому +2

    Sir Mumbai me thekedaar slump nhi karne dete hai even 22+ floor building me true i worked

  • @dhirajprajapati1248
    @dhirajprajapati1248 3 роки тому

    Sir, u don't tell us where to use the 0 slump value and high shear slump value

    • @fazalurrahman3983
      @fazalurrahman3983 3 роки тому

      Zero slump we use mass products, such as sewage pipes, concrete slabs, paving blocks, masonry blocks, roofing tiles, and curbstones

  • @TheSumit5555
    @TheSumit5555 3 роки тому

    Sir slump test me temping 4x25 karni hai ya only 25 time hi krni hai

    • @Civilengineerin832
      @Civilengineerin832 5 місяців тому

      Cone 4 layer mai bhrna hota hai hay layer ko 25 br dump kya jata hai

  • @AmitDas0110
    @AmitDas0110 Рік тому +1

    Sir btech complete hone ke baad apke institution mei training Lena hai sir🙏🏻❤️

    • @Civil_Guruji
      @Civil_Guruji  Рік тому +1

      Thank you
      Amit Das
      Hame bohat khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
      KEEP LEARING, KEEP SHARING.

  • @imteyazalam9269
    @imteyazalam9269 2 місяці тому

    Slump jyada hone se concrete weak hota hai n sir

  • @erdurgeshkumar8932
    @erdurgeshkumar8932 3 місяці тому

    Sir iska value kitna hota hai

  • @maklangry5742
    @maklangry5742 Рік тому

    Hi Dr... please do a video in English....🤲

  • @shahidrayeen5451
    @shahidrayeen5451 2 роки тому +2

    not 4layer 3time 25time tampe road....lol

  • @f.p798
    @f.p798 Рік тому

    Ulta stand rakh k test kr diya h

  • @arshadkhan..
    @arshadkhan.. 11 місяців тому

    Astm 143 method ke acording nahi hai ye slump test oura method galat hai apka

  • @sabirshaikh7506
    @sabirshaikh7506 Рік тому

    Calculations 😢

  • @shanuahmad9647
    @shanuahmad9647 3 роки тому +1

    Sir base ulta kyu rkha h

  • @joetom99
    @joetom99 3 роки тому +1

    Really pathetic, zero information