Troubleshoot NGTP unit - Adjust Spring of Door Unit

Поділитися
Вставка
  • Опубліковано 7 лют 2025
  • Problem: The NGTP (Nayati Gas Tilting Pan) door is not holding up when released.
    Solution: Adjust the spring to ensure the door stays up.
    Tools Needed:
    Screwdriver
    Wrench
    L3 Allen key
    Steps:
    1. Remove the Cover:
    Locate the large screw on the door.
    Unscrew it by hand or using a wrench.
    2. Adjust the Spring:
    Use the M12 screw and the provided tool.
    Insert the M12 screw into the designated hole and turn it until it's tight.
    Tighten the screw holding the M12 screw in place.
    Use the L3 Allen key to loosen the smaller screw.
    Adjust the smaller screw as needed to fine-tune the spring tension.
    3. Test the Door:
    Release the door to check if it holds up.
    If not, repeat step 2 and make further adjustments.
    4. Secure the Cover:
    Once the door is functioning correctly, tighten the cover screw.
    Tips:
    If the screws are difficult to turn, use a lubricant.
    Ensure that all screws are tightened securely.
    Be careful not to overtighten the screws, as this could damage the mechanism.
    Troubleshooting:
    If the door still doesn't hold up after following these steps, there may be an issue with the spring itself, and it may need to be replaced