💪⚡ТТР и радиаторы. Installation of the temperature sensor into the SSR cooling radiator.

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • ТТР и радиаторы.
    Автоматика для дистилляции и ректификации.
    Установка датчика температуры в радиатор охлаждения ТТР.
    Собрать регулятор мощности для ТЭНов и электроплиток.
    ❗❌НЕ ПОДХОДИТ ДЛЯ ИНДУКЦИОННЫХ ПЛИТ!!!.❌❗
    The permissible value of the load current indicated on the case of the solid-state relay and present in its designation is valid when the heating temperature of the relay itself is not higher than 40 ° C (this is true for the SSR of any manufacturer). If the SSR temperature exceeds 40 ° C, then the permissible value of the load current will decrease. For example, when the SSR is heated to 70 ° C, the permissible load current through it will be only 50% of the nominal current specified in the passport. In practice, a load with a current consumption of more than 5A already leads to a heating of the SSR over 40 ° C. Therefore, in order to comply with the operating conditions of SSRs, it is extremely important to take measures to limit their heating above the permissible nominal temperature value.
    Допустимая величина тока нагрузки, указанная на корпусе твердотельного реле и присутствующая в его обозначении, справедлива при температуре нагрева самого реле не выше 40°С (это справедливо для ТТР любого производителя). Если же температура ТТР превысит 40°С, то допустимое значение тока нагрузки уменьшится. Например, при нагреве ТТР до 70°С, допустимый ток нагрузки через него составит всего 50% от указанного в паспорте номинального значения тока. На практике нагрузка с током потребления свыше 5А уже приводит к нагреву ТТР более 40°С. Поэтому для соблюдения условий эксплуатации ТТР крайне важно предпринимать меры по ограничению их нагрева свыше допустимого номинального значения температуры.

КОМЕНТАРІ •