    @juanarana4814 5 місяців тому +1

    I didn't see fireblocking provided on stairway (conceal spaces) nor some horizontal spaces.

    • @DTLification
      @DTLification Місяць тому

      yup, he missed it. one of the most important ones in my opinion

  • @rickm6335
    @rickm6335 7 місяців тому +1

    Nice video. Informative and to the point. Thanks.

    • @PPRBD
      @PPRBD  6 місяців тому

      Thank you. We hope it was helpful.

  • @pint_size_crawler
    @pint_size_crawler 2 роки тому +1

    Awesome did not know that about the unders stairs storage.

    • @PPRBD
      @PPRBD  2 роки тому

      Glad the video was helpful.

  • @5337255
    @5337255 5 років тому +2

    Well done Dakota, good info!

  • @TeslaBoy123
    @TeslaBoy123 3 роки тому

    Flooding framing open my mind idea I like it a lot 👍👍👍👍👍👍👍👍

  • @user-lk1tp7su5d
    @user-lk1tp7su5d Місяць тому +1

    So in order to be considered a bedroom, it MUST have a 16 in deep closet?

    • @PPRBD
      @PPRBD  Місяць тому

      Correct. On page 64 of the 2023 RBC is the definition of a sleeping room and it states that it will have a closet at least 16” deep. I have attached a link to the RBC below. Thanks.
      www.pprbd.org/File/ByAlias/2023PPRBC

  • @gregoryschultz3063
    @gregoryschultz3063 3 роки тому +8

    Hi Dakota, I have a wrapped basement I’m finishing. Do I need draft stopping for that? All videos I’ve seen show examples of concrete walls vs a wrapped basement with insulation. Thanks. By the way, best video I’ve found regarding inspection, so thank you. Very helpful.

    • @jrod16sports
      @jrod16sports 3 роки тому +2

      Did you find out about this?

  • @cleonchristian8374
    @cleonchristian8374 10 місяців тому +1

    Do the fire detectors and carbon dioxide detectors MUST be hard wired ?

    • @PPRBD
      @PPRBD  10 місяців тому

      Hi there, thanks for reaching out. The smoke and carbon monoxide alarms in the area of the scope of work must be hard wired for the structure. So if the permit is for a basement finish all of the smoke and CO alarms in the basement finish where the wall and ceiling finished are removed must be powered from the electricity of the house (hard wired). The smoke and CO alarms on the other floors that must be installed in the required areas such as bedrooms and outside of bedroom groups, can be battery powered, but must still be interconnected (wirelessly) so that if one goes off they all go off. Hope this helps.

  • @listenkaren8222
    @listenkaren8222 9 місяців тому

    what about the pressure treated thats suppose to be in contact with the floor?

  • @richardmckrell4899
    @richardmckrell4899 3 роки тому +1

    no horizontal fire stops

  • @georgefrattolin8710
    @georgefrattolin8710 2 роки тому +1

    If I have a floating floor do we need to still put floating walls?

  • @mr.reeftank1456
    @mr.reeftank1456 4 роки тому +1

    Is bigger nail ok thats not 60d say a 10in galvanized nail?

  • @_tikinick_
    @_tikinick_ Місяць тому

    The 60D spikes, can they be less than 32" on center i.e. if I put on every gap at 16" center? Is 32" the max spacing? Thanks

    • @PPRBD
      @PPRBD  23 дні тому +1

      Yes, the 32” OC is the maximum they can be spaced. If you want to add even more spikes you certainly can and it will meet the requirements.

  • @celestialdream49
    @celestialdream49 3 роки тому +4

    The Spray form needs to be the "Fire Retardant" rated fill foam.

  • @jeanpaulrodriguez3367
    @jeanpaulrodriguez3367 3 роки тому +1

    Dakota could you please tell me how far from the concrete wall can i build the wood wall and and can i use 2 1/2 in or 3in nails to secure the base plate

    • @PPRBD
      @PPRBD  3 роки тому

      You can build a wood wall 1” from the concrete foundation wall. You'll need 3” nails to secure the studs to the bottom plate.

  • @fernandomolina6809
    @fernandomolina6809 Рік тому

    I see that there are floating walls for when the concrete slab moves up. What about the doors? Usually the door frame just sits right on the concrete slab, or maybe 1/4" off the floor. What happens if the floor moves up?

    • @PPRBD
      @PPRBD  Рік тому

      Good morning. Your door jams will set on the concrete but there will need to be a gap above the jam and below the header in the rough opening. You will still attach the jam to the floating wall but if the floor moves it will only move the door out of adjustment but will not ever be able to push the wall up into the floor joists and cause any structural damage. Hope this helps.

  • @szargos
    @szargos 2 роки тому +2

    You don't need pressure treated wood on your slabs? Interesting.

    • @candacemoon9671
      @candacemoon9671 2 роки тому

      Right?, any wood touching concrete, iiiiiinteresting.

  • @lovemafia8317
    @lovemafia8317 4 роки тому +1

    Hi, I've one question.. I'm Framing my basement, can i leave 6 inch space from the wall, i wanna make wider window sill. is it fine to do it?

    • @PPRBD
      @PPRBD  4 роки тому

      Yes it’s fine to make your window sills wider but sills must still be less than 44” above the finished floor for egress windows and all draft stop requirements are still the same.

  • @RandomTechWZ
    @RandomTechWZ Рік тому +2

    WTF is up with the music as soon as he starts actually talking about what we all want to hear.

  • @senfo-s5p
    @senfo-s5p 2 роки тому

    Could you please give some guidance on fire blocking for basement soffits? Do you need to fireblock the area above whatever is inside the soffit (e.g., above the ductwork)? I'm genuinely concerned how to achieve that.

    • @PPRBD
      @PPRBD  2 роки тому

      Hi Sean. Sorry for the delayed response, but we have another video on draft stopping and fire blocking that should be helpful. ua-cam.com/video/OzDQHs6zt6k/v-deo.html

  • @trevorcroft85
    @trevorcroft85 5 років тому +3

    Dakota should get a raise. Great work.

  • @alsteeves2044
    @alsteeves2044 Рік тому

    Drywall the understair storage??
    No wonder construction costs keep rising, with more and more "codes" being added.

  • @KobeConfidence
    @KobeConfidence 3 роки тому

    Is that floating wall a requirement everywhere?never seen that before to be honest and at the time my house was built the small ammount of framing they did do didnt have floating walls

    • @PPRBD
      @PPRBD  3 роки тому

      Hi Kobe, the floating wall is not required everywhere, but it is required here in the Pikes Peak region and the 8 jurisdictions we serve. If you have any questions, we're happy to help.
      If you aren't in our area, I encourage you to check out your local building codes.

  • @havalhasan6463
    @havalhasan6463 Рік тому

    What product do you recommend for the draft stopping of the walls?

    • @PPRBD
      @PPRBD  Рік тому

      We actually have a separate video on draft stopping that will be helpful. ua-cam.com/video/OzDQHs6zt6k/v-deo.html

  • @anthony661990
    @anthony661990 3 роки тому

    Can you build the floating wall with steels studs?

    • @PPRBD
      @PPRBD  3 роки тому

      Hi Anthony. You can still float your wall with steel studs and this can be achieved in a couple different ways. You can use what is referred to as “Slip Track” on your top plate. You can also cut your studs an inch short at either top or bottom. Hope this helps.

    • @dj-nr8nm
      @dj-nr8nm 2 роки тому

      @@PPRBD Could you use wood for the bottom plates and then steel for the rest of the wall to float it?

  • @DM-mz7zh
    @DM-mz7zh 4 роки тому +1

    Good info, thanks! Next time would be great with no music, so we can hear you better.

    • @PPRBD
      @PPRBD  4 роки тому

      Thanks for the feedback Danielle. Glad you and enjoyed it. We'll be sure to keep the music volume low on future videos.