Hack: Increasing the time and adding reset switch to 555 Relay Timer

Поділитися
Вставка
  • Опубліковано 28 лис 2024

КОМЕНТАРІ • 137

  • @frankcaccamo3568
    @frankcaccamo3568 3 роки тому +7

    I’m only going to say , how smart all you people are. I’m slowly learning and enjoying all this. Fantastic

    • @robojax
      @robojax  3 роки тому +1

      Welcome to electronics. I am glad you liked it. Please browse my channel and you will be amazed. Please don’t forget to subscribe. I appreciate it.

  • @mrcountry
    @mrcountry 2 роки тому +2

    Thank you for your tutorial. I need the reset button. Two thumbs up 👍👍

    • @robojax
      @robojax  2 роки тому +1

      You're welcome!

    • @tnamen1307
      @tnamen1307 3 місяці тому

      ​@@robojaxsir can you please help me...
      I just purchased and received the same module.
      When power is ON, after some seconds, the relay is OFF. This is normal.
      But after that, the relay is ON and OFF. This is repeated as long as power is ON.
      Please help me fix to ON the relay only for some seconds.

  • @rickneill6924
    @rickneill6924 3 роки тому +2

    Thanks. I needed an external reset. You saved me a lot of time. 👍👍 ✔️✔️

  • @hefnijaber7088
    @hefnijaber7088 10 місяців тому

    Dear Mr. Ahmed it is great explanation as per my understanding this time delay for circuit off ( ie circuit switch off after predetermined time ) I do not no if can modify such circuit to be delay for circuit on ( ie circuit switch on after predetermined time ) best wishing and regards

  • @nalindathushara3065
    @nalindathushara3065 Рік тому

    Can i use this timer for beam sensor,v for increase the alarm response time

  • @HaroldMitchell-v7b
    @HaroldMitchell-v7b 10 місяців тому

    😊 thank you for this video! Your the best!

  • @ahmedqatar5944
    @ahmedqatar5944 Рік тому

    Hello brother, thank you for your effort. I want to use this circuit to turn on and off the parking lights in cars. How can it be used? Is another relay added or the same circuit used?

  • @patrickb3469
    @patrickb3469 4 роки тому +3

    Hi, I followed the wiring for the switch minus the additional capacitor but not resetting. Mine module seems to work opposite yours. Only one led on until it reaches time then both on, while yours starts with both on and turns off. What's going on there?

    • @robojax
      @robojax  4 роки тому +1

      then either your module is different or you've connected the load wires different. I am not sure.

    • @shubhamjain7036
      @shubhamjain7036 3 роки тому

      I have same module.
      Our modules are different

  • @zeeshanshabbir4018
    @zeeshanshabbir4018 3 місяці тому +1

    In this video for increase delay time you have added 220uf capacitor on the back side and 100uf capacitor still connected, can you plz tell have you remove 100uf capacitor when conneted to 220uf capacitor or you used both one at a time means 220uf + 100uf = 40seconds+?????????

    • @robojax
      @robojax  3 місяці тому +2

      it seems you haven't watched the video. if you did, you would clearly see if the older capacitor is there or not.

    • @zeeshanshabbir4018
      @zeeshanshabbir4018 3 місяці тому

      @@robojax i have replace 100uf capacitor with 330uf capacitor but my circuit relay not working, can you please tell me? and when i insert back 100uf capacitor its starts working again. i want to increase time for 20 seconx

    • @zeeshanshabbir4018
      @zeeshanshabbir4018 3 місяці тому

      @@robojax i have ON delay timer circuit which looks same as yours, i want to increase time from 10 sec to 20+

    • @tnamen1307
      @tnamen1307 3 місяці тому

      ​@@robojax Can you please tell..
      I want the timer not to start automatically when power is connected. Only when the trigger switch/push button is pressed, the timer should be ON. How to achieve this feature?
      Please help.

  • @ranaqamarali109
    @ranaqamarali109 Рік тому

    Sir you are best teacher

    • @robojax
      @robojax  Рік тому

      I am glad to be helpful.

  • @rafikulrahaman9321
    @rafikulrahaman9321 4 роки тому +2

    Very nicely explain, thanks.

    • @robojax
      @robojax  4 роки тому

      You are welcome!

  • @MechanicForGMCCars
    @MechanicForGMCCars Рік тому

    Sir I hoppe you can answer my question I like to use hv ceramic capacitors with my hei ignition system series of capacitors soldered together and I place it any where on my e core ignition coil mostly coil + side the other side I ground to chassys or wia some trip switch .
    Now the problem acured my car is 80s Opel it has the Delco 12si alternator I think its A circuet alternatir I use only pin 1 with light bulb the other pin 2 isnt used I do not have any diodes in my car only bulb when ever I use those multipel 3 kw capacitors in seies my alternator starting charge gets displaced so my alternator constantly back feading true the bulb unless I give it more revs and the alternator starts charging my baterry and the alternator light goes off but If I run on normal idel speed the bulb turns on again .
    So can you tell my please what thoes capacitors have to do with the alternators voltage regulator amd how can I counter this strange effect?
    How much I culd understand inside my alternator regulator I found miniature ic chip and 2 small capacitors how much I culd understand the ic chip is also baterry negative voltage potential controled some sort of?
    So how to chuse capacitor or value to counter this effects?
    I have lot capacitirs resistors and 500k potenciometer also have insulated alternator voltage regulator screws but dont know how its calculated out come that my alternator charges in what rpm ranges.
    So I hoppe you understand my question .
    So Im not shure what to use honestly resistor/capacitor box ,cloosed loop voltage regulator Im still cinde of woried to over charge my baterry

  • @omarhamada221
    @omarhamada221 5 місяців тому

    What capacitor would it take to increase time half an hour?

    • @robojax
      @robojax  5 місяців тому

      It is R times C but I did not try it. So experiment with different size. Once you find time for a certain size then you know the what size to capacitors to use. Is simply try sizes.

  • @HardcoreEDM
    @HardcoreEDM 6 місяців тому

    Correct me if i am wrong, you increase the charge capacity by parallel capacitor, so it will take longer time to charge the capacitor?

    • @robojax
      @robojax  6 місяців тому

      the larger the capacitor, the longer the time that holds. Yes.

    • @HardcoreEDM
      @HardcoreEDM 6 місяців тому

      @@robojax Something wrong, the relay went on and off very repeatedly, sometime it's duration became shorter, seem like not enough current.

  • @ABUHUZAIFA1979
    @ABUHUZAIFA1979 Рік тому

    Alsalam o Alikum
    I want to convert this module to 5v ,
    And use 3-32 v npn sensor to restart timer,
    Input power supply regular on ,
    Bro tell me how can I do ,
    JazakAllah

  • @sorenweisshartmann
    @sorenweisshartmann 3 роки тому

    Thanks for an excellent video, well explained. :)

  • @Rodatum
    @Rodatum 6 місяців тому

    I'd like to make a delayed start signal for a project but I can't wrap my brain around these timers offered on Amazon.
    I have an inverter (Schneider Electric XW+) that will use a battery bank to power my critical loads. It can also get power from a generator that it will start when told to do so.
    I want to connect a 12vDC relay to a power adapter connected to a grid outlet, that is, not a critical load outlet. When the power goes out the relay will switch and the normally open connection will close. That's the trigger that the grid power is out.
    That trigger needs to delay start the generator after grid is down for 15 minutes by momentarily closing a connection on the inverter. However if the grid comes back up before the 15 minutes then everything is canceled, that is, I don't want to signal the inverter to start the generator.
    Another delayed timer relay is to stop the generator after the grid is up for 15 minutes. If it comes up and then down again before the 15 minutes, then nothing happens. But if the grid stays up for 15 minutes, (12vDC relay connected to grid power adapter is on), then a different connection on the inverter is momentarily made signaling it to stop the generator and return to using grid power for the critical loads.
    Any thoughts, comments, ideas, etc. will be appreciated!
    Thank you

  • @gerryjamieson1861
    @gerryjamieson1861 4 роки тому

    Hello. I'm not sure if you can suggest a fix for my situation. I have a 2005 Dodge Grand Caravan. The rear intermittent wiper motor, when turned on pulses the wiper every 6 seconds. This is very annoying. Can what you are showing help me to control an increase in time between impulses. Ideally I'd like the rear wiper to pulse on between 30 seconds and a minute. Thank you

    • @robojax
      @robojax  4 роки тому

      Hello, you can't change that timer. but you can change the continuous operation by putting this relay on the path of motor wiper.

  • @taniorganik4702
    @taniorganik4702 3 роки тому

    Assalamualaikum i am from Indonesia

    • @robojax
      @robojax  2 роки тому

      walaikum salam Tani from Indonisia.

  • @vaskovaskez2053
    @vaskovaskez2053 2 роки тому +1

    Hi, excelente explain, thanks ... I have same module but as delay on mode ... Can you explain how to change to delay off mode

    • @robojax
      @robojax  2 роки тому

      For the load just connect it to the middle and other connector of the relay and the operation will be reversed. Instead of On it will OFF

    • @vaskovaskez2053
      @vaskovaskez2053 2 роки тому

      @@robojax Thanks for quick response!
      Obviously I was not explained right, sorry for my english...
      My module work opposite than yours. When I turn power on after couple of seconds (after desired time delay) the relay turn on and green light is on unlimited time. On your video it is opposite, after turn power on or push the swich you have desired time delay for relay and green light turned on after that it turned off.
      Can I do something to change operation mode as on your module?

  • @tnamen1307
    @tnamen1307 3 місяці тому

    Very helpful video.
    But you forgot to mention one thing....
    In the video, the TIMER RELAY is automatically ON when the power is connected. And, you need the push button to restart the timer. That's ok.
    But, what I want is the timer should not start automatically when power is connected. Only when the trigger switch/push button is pressed, the timer should be ON. How to achieve this feature?

  • @AhmedRaza-he9tg
    @AhmedRaza-he9tg Місяць тому

    0 timer delay off on router reset me fast switching module Relay please help me

  • @hefnijaber7088
    @hefnijaber7088 10 місяців тому

    Kindly I request you to provide sketch for this best regards

  • @cobraAH1
    @cobraAH1 3 роки тому

    hi, how about adding proximity sensor switch?

    • @robojax
      @robojax  3 роки тому

      Hi, use any switch that creat the same high or low state.

  • @Kris0725PL
    @Kris0725PL 3 роки тому

    This is very good!

    • @robojax
      @robojax  3 роки тому

      You are welcome. Please subscribe. I appreciate it and helps my channel grow. Thank you

  • @emiliojosedavidpardodiaz6562
    @emiliojosedavidpardodiaz6562 3 роки тому +1

    Excelente video,muchas gracias por agregar la traducción así puedo entenderlo en español, me suscribo de inmediato a tu canal tienes información muy valiosa, muchas gracias de nuevo!

    • @robojax
      @robojax  3 роки тому

      Me alegra saber que el video y la traducción te resultaron útiles. Gracias por suscribirte. Mantenerse a salvo.

  • @Electronzap
    @Electronzap 10 місяців тому

    Clever.

  • @jan5504
    @jan5504 Рік тому

    why my time delay won't work if the electricity gets cut out and immediately return, I want to use it as a surge protector but with this it removes it's purpose...

  • @Shawbonez
    @Shawbonez 4 роки тому

    Hi! Great video! I will add the reset button, but how many amps will relay handle for 12v? I want to use as a kill switch in my vehicle to turn off 10A starter fuse. Tnanks!

    • @robojax
      @robojax  4 роки тому

      Hi, thanks. it seems you have directly jump to this video while I mentioned that yo have to watch the introduction here ua-cam.com/video/RjWW4nbUyio/v-deo.html

    • @anthonysleight9244
      @anthonysleight9244 3 роки тому +1

      Use this relay to operate auto relay

    • @Shawbonez
      @Shawbonez 3 роки тому

      @@anthonysleight9244 Thank you!

  • @TheTtreasure
    @TheTtreasure 2 роки тому

    Hi, how are you connecting the push button switch to the circuit??

    • @robojax
      @robojax  2 роки тому

      Hi, it is shown in video and that’s why I made this video

    • @TheTtreasure
      @TheTtreasure 2 роки тому

      @@robojax OK, thanks, the reset switch is the same energizing switch, right?

    • @robojax
      @robojax  2 роки тому +1

      we have one switch and whatever you call it.

    • @TheTtreasure
      @TheTtreasure 2 роки тому

      Thanks man

  • @narendrabhatia6140
    @narendrabhatia6140 Рік тому +1

    V NICE EXPLAIN 👍👍👍🙏🙏

  • @hefnijaber7088
    @hefnijaber7088 10 місяців тому

    Dear Mr. Ahmed please provide circuit diagram for this module best regards

    • @robojax
      @robojax  10 місяців тому

      Hi, as simple search for "555 timer circuit diagram" showed this www.circuits-diy.com/time-delay-relay-using-555-timer-ic/

  • @ahmedeskafi8670
    @ahmedeskafi8670 3 роки тому

    if i turn off the main power and turn it on again the relay will start working directly whit out press the button right ? than how i make relay run by just pressing the button even if i restart the main power ?

    • @robojax
      @robojax  3 роки тому +1

      yes. Use Arduino. forget about this ua-cam.com/video/6DGQhQgr7Ak/v-deo.html or this ua-cam.com/video/BhEIFzFSMuE/v-deo.html

    • @ahmedeskafi8670
      @ahmedeskafi8670 3 роки тому

      @@robojax thanks for reply 😊🌹

  • @lllAstridddlll
    @lllAstridddlll 4 роки тому +1

    👍👍il serait intéressant de lui ajouter une extinction automatique du module une fois le décompte fini 👍

    • @robojax
      @robojax  4 роки тому

      possible. but it would need another switch to turn it ON again.

  • @wootdeco
    @wootdeco 2 роки тому +1

    It seems that there are two versions of this module. One that is ON and then it shuts OFF after timer and one that is OFF and turns ON after timer. On the first video you have second one and on this video you have first version. It's strange that there is second version since then relay is on all the time and you still have NC and NO open connections. Anway since this video i managed to rewire mine to put capacitor in place of potentiometer and potentimeter in place of capacitor.

    • @cdrive5757
      @cdrive5757 2 роки тому

      Robojax should pin your comments as the top comment. From what I've read in these comments you're the only viewer that understands how this chip works. Including Robojax. Sadly, it's buried down deep in replies. You're absolutely correct in your assessment of this board. The logic as it configured is ass backwards. I've worked with the 555 for over 49 years and have never seen one wired like this one. It's absurd to have a board that spends 60 seconds with the relay de-energized while the rest of the 24 hour day the relay is energized and the board is powered on! WTF? Surfing through the data sheets I think anyone would be hard pressed to find Rt tied to GND and Ct tied to Vcc! It's simply unorthodox and inefficient. My 555 project is intended for a self cleaning (60 sec) filter cleaning cycle for my shop vac. Note: For fast recovery (re -trigger) add a reversed biased Diode across 'Rt' timing resistor. It speeds up discharge of the timing cap 'Ct'.
      Wakodahatchee Chris

  • @obedobi5554
    @obedobi5554 3 роки тому

    Hi,
    Is it possible i can use a limit switch instead of reset switch. And as soon as the limit switch is pressed, the power is cut off, and after 2 seconds the power starts again irrespective of limit switch is kept pressed or depressed.
    Thanks

    • @robojax
      @robojax  3 роки тому

      Hi, this can't do anything else. see other modules ua-cam.com/users/RobojaxTVsearch?query=Timer or Learn Arduino in 30 Minutes (video): robojax.com/L/?id=135

  • @marisamorena8452
    @marisamorena8452 3 роки тому

    I people I need some help 😢
    I have that module and I think they never work (relay and green led) try same circuit 12v for lamp.
    how do I fix it and make it loop 10sec on 10sec off ?

    • @robojax
      @robojax  3 роки тому

      Can’t do loop see this ua-cam.com/video/81XzLwt3dqo/v-deo.html

  • @GoodMods
    @GoodMods 4 роки тому

    Hi Robojax, I need your knowledge... I want to have a module which I can connect to my computer and adjust it on there, and set the time between 0-1 second, so i want microseconds... Or adjust the microsettings with my phone, what module do I need? thanks

    • @robojax
      @robojax  4 роки тому

      hi, you need Arduino with relay. I have tones of videos on that.

    • @GoodMods
      @GoodMods 4 роки тому

      @@robojax also microseconds? You have any links to one of them?

    • @robojax
      @robojax  4 роки тому

      You were talking about relay which can never be turned on of at microseconds. Relay is very slow like I.2 seconds

    • @GoodMods
      @GoodMods 4 роки тому

      @@robojax i need something which is very fast, like 0.1 seconds or 0.2 seconds

    • @robojax
      @robojax  4 роки тому

      relay is not good option for that. relay is mechanical switch and I am not sure if it responds at 0.1s very well.. if you control DC load you can use mosfet and if you control AC load then use TRIAC to turn ON or oFF quickly.

  • @Bernhard_V
    @Bernhard_V 4 роки тому

    Hi Robojax, is it possible to make a hack for battery-powered lamps?
    The timer module is not connected to the voltage. Only when the push button is pressed, the module is supplied with voltage via the relay and after the time, everything is disconnected again. So the lamp and the module do not need any power. Is that possible?

    • @robojax
      @robojax  4 роки тому

      Hi, we have control system and the lamp. Relay and controller must have power available to them. They simply disconnect the lamp.

  • @thanhtrung.productions
    @thanhtrung.productions 8 місяців тому

    How to do it: when the first trigger signal causes the relay to close, if the waiting time has not expired, if we add another signal, the module will only reset the time without the relay opening. Until the last signal's waiting time expires, the relay will open.

    • @robojax
      @robojax  8 місяців тому +1

      Hi, may be you need a device like this Home Automation: How to use 7 Program 0.1s to 9999 minutes Relay Timer XY-LJ02
      ua-cam.com/video/s4oNCpH_I0E/v-deo.html and I have more videos on different modules, just search

  • @griffmoses8043
    @griffmoses8043 2 роки тому

    I asked for help about why the push button reset does work. It is connected just as you describe in this video but it will not reset. Please help!!

    • @robojax
      @robojax  2 роки тому

      It must work if you do it properly.

  • @terryroe2023
    @terryroe2023 3 роки тому

    How about adding a PIR sensor to activate the relay? Can be done?

    • @robojax
      @robojax  3 роки тому +1

      Hello, yes watch this video ua-cam.com/video/mZCJNOf69JI/v-deo.html and instead of Arduino, connect it to this module. I believe it should work.

    • @terryroe2023
      @terryroe2023 3 роки тому

      @@robojax I shall watch right now

    • @terryroe2023
      @terryroe2023 3 роки тому

      @@robojax maybe wrong video, it's about arduino connection

    • @robojax
      @robojax  3 роки тому

      that is correct video. you learn how the motion sensor works. the sensor simply outputs voltage and you connect it to this timer instead of Arduino. if trigger level is the opposite of what you expect, then make circuit like this snipboard.io/vERWPt.jpg to change HIGH level to LOW or in reverse.

  • @thinkingpanot5283
    @thinkingpanot5283 2 роки тому

    What will happen if i press and hold the reset button? Is the time will not run?

    • @robojax
      @robojax  2 роки тому

      It will be on . I believe I have shown and pressed it. When you release the time count down starts

  • @GerryJ08
    @GerryJ08 4 роки тому

    Can you please explain what you mean. Thanks

    • @robojax
      @robojax  4 роки тому

      First of all you are watch the wrong video. Please watch this video ua-cam.com/video/RjWW4nbUyio/v-deo.html and instead of bulb shown in the video, connect the positive wire going to the motor of your wiper. this will work when you set the wiper in continuous mode and this module will intervene and turn ON or OFF at interval required. I am sorry I can't explained better than this. See also this image snipboard.io/AHhRpV.jpg

  • @electronic7979
    @electronic7979 4 роки тому +1

    👏👏👏

  • @riyagupta-ob3gh
    @riyagupta-ob3gh 11 місяців тому

    1000uf 50v and 1m after remove trimpot increase 10min

  • @rashidnoor5477
    @rashidnoor5477 3 роки тому

    I dont understand on fixing reset switch please explain again

    • @robojax
      @robojax  3 роки тому

      It is done. Play it 2,3, or 4 times

  • @lordrahulcool
    @lordrahulcool Рік тому

    Can i make it 2 hours???

    • @robojax
      @robojax  Рік тому

      Anything you like. Just add larger capacitor

  • @shubhamjain7036
    @shubhamjain7036 3 роки тому

    Sir
    May I get circuit diagram?

    • @robojax
      @robojax  3 роки тому

      Not available.

  • @taniorganik4702
    @taniorganik4702 3 роки тому

    Thks for subscribe

  • @sorenweisshartmann
    @sorenweisshartmann 3 роки тому

    How do you increase the time to 60 seconds? Thanks

    • @robojax
      @robojax  3 роки тому

      That is exactly why I made the video to tell

    • @sorenweisshartmann
      @sorenweisshartmann 3 роки тому

      @@robojax With 220 it goes to about 40 second. What would.it take to go to 60 seconds?

    • @robojax
      @robojax  3 роки тому

      I did not calculate it. just experiment. the capacitor size is unknown.

    • @omarhamada221
      @omarhamada221 5 місяців тому

      Please did you knew how to do this

    • @omarhamada221
      @omarhamada221 5 місяців тому

      ​@@sorenweisshartmannPlease did you knew how to do this

  • @electronicsandsweets5424
    @electronicsandsweets5424 4 роки тому

    Good

    • @robojax
      @robojax  4 роки тому

      Thanks

    • @electronicsandsweets5424
      @electronicsandsweets5424 4 роки тому

      Sir i copy your video and share on our chnal but you gevme permission to i convert in our league

  • @jonalynrapsing410
    @jonalynrapsing410 2 роки тому

    I try it.but push button is not working.

    • @robojax
      @robojax  2 роки тому

      You just have done something wrong. Check again

  • @shubhamjain7036
    @shubhamjain7036 3 роки тому

    Where is trigger pin connected?

    • @robojax
      @robojax  3 роки тому +1

      You have skipped the video. Please watch fully

    • @shubhamjain7036
      @shubhamjain7036 3 роки тому

      @@robojax extremely sorry sir
      Video was very helpful

  • @shubhamjain7036
    @shubhamjain7036 3 роки тому

    Sir
    Where is pin 7 connected?

    • @robojax
      @robojax  3 роки тому

      I don’t have the board , just look at it from both side and use multimeter to figure it out. Also look at 555 timer datasheet you easy read it.

    • @rickneill6924
      @rickneill6924 3 роки тому

      In this use of the NE555, pin 7 is not used. It is the discharge pin for a timing capacitor. In an astable multivibrator circuit it would be used to discharge the timing capacitor to continually repeat the charging cycle. In this case the NE555 is used to create a monostable multivibrator (Also called a "one-shot") so pin 7 is simply not connected to anything.

  • @kamleshpatel2684
    @kamleshpatel2684 2 роки тому

    I have added a capacitor so IC is heating what is problem& solution

    • @robojax
      @robojax  2 роки тому

      capacitor is should not do anything. you must have connecting the + and - in reverse. Capacitor should explode if you connect it in reverse.

    • @kamleshpatel2684
      @kamleshpatel2684 2 роки тому

      I heve using 470 uf/35 v capacitr with polarity pl. Solution

  • @akutenshi7023
    @akutenshi7023 4 роки тому

    Ohh cool

  • @suplado7583
    @suplado7583 Місяць тому

    I found module relay timer up 12 hours

    • @robojax
      @robojax  Місяць тому +1

      here is 9999 minuets (166.65 hours) ua-cam.com/video/s4oNCpH_I0E/v-deo.html

    • @suplado7583
      @suplado7583 29 днів тому

      ​@@robojax that's 7 days

  • @sayedalibahrain5592
    @sayedalibahrain5592 2 роки тому

    Rest not working

    • @robojax
      @robojax  2 роки тому

      Working . You are not doing right . I have shown on video . Watch again

  • @manojvc6356
    @manojvc6356 4 роки тому

    😍