Thank you for this informative video. What happens to the saline water which should be ejected from the desalter? From your flowsheet, it seems that the saline water is sent with the wet warm crude to the heater and onwards to the distillation column.
I used aspen v8.8 and did everything step by step according to the video, yet for some reason message board keeps saying that sulfur-1,2,3 were not defined for mix oil and that there was an error calculating hypothetical component NBP[0]1021. Could you hint me what might be the problem?
Hi Mr, Can you please enlighten me about the purpose of mixing water initially? If we need to desalt don't we need to add 3 phase seperator? Also please tell me how to estimate number of trays required for crude distillation.
When calculating assay, in message board it says "All assay values equal to or greater than 90,00 result in calculated TBP temperatures exceeding maximum of 1100°C [2012°F]. Resulting critical and physical properties could be erroneuos. Please check your assay data. Assay is still calculated. Should this message just be ignored sir?
Thank you for kind lecture.
Thanks a lot for many your helpful guided videos
Ma sha Allah good effort
Thank you for this informative video. What happens to the saline water which should be ejected from the desalter? From your flowsheet, it seems that the saline water is sent with the wet warm crude to the heater and onwards to the distillation column.
Great work 👏
Nice well done 👍🏻
Please share excel sheet link
Please
Please msr just a question
What is the use of Mix in this process?
Every refinery is designed to process crude oil at certain properties , which sometimes achieved by blending of more than one different crude oil.
I used aspen v8.8 and did everything step by step according to the video, yet for some reason message board keeps saying that sulfur-1,2,3 were not defined for mix oil and that there was an error calculating hypothetical component NBP[0]1021. Could you hint me what might be the problem?
Hi Mr, Can you please enlighten me about the purpose of mixing water initially?
If we need to desalt don't we need to add 3 phase seperator?
Also please tell me how to estimate number of trays required for crude distillation.
Бас алға!
While installing oil its showing one or more oil cannot be installed due to missing names. Can you plz solve this issue
Where do you come from the data about the furnace?
Thanks bro
What's the difference between Petroleum Assay and Oil Manager?
hi mr.
can i have your datasheet? Imean your excel file you used in this video.
When calculating assay, in message board it says "All assay values equal to or greater than 90,00 result in calculated TBP temperatures exceeding maximum of 1100°C [2012°F]. Resulting critical and physical properties could be erroneuos. Please check your assay data. Assay is still calculated. Should this message just be ignored sir?
Can i get excel file?