How to design a steel column using an easy approach.

Поділитися
Вставка
  • Опубліковано 30 вер 2024

КОМЕНТАРІ • 47

  • @boy-br2tr
    @boy-br2tr 2 роки тому +7

    Can you sample a building design from roof down to foundation structual analysis?..

    • @cnjrq
      @cnjrq Рік тому

      I have a complete tutorial on how loads are distributed from roof to foundation via columns. You can watch example 2 in my recent tutorial on steel columns ua-cam.com/video/XQipsi8Je2Q/v-deo.html

  • @shahedsiddiki1165
    @shahedsiddiki1165 2 роки тому +4

    It's a good video but we want more about column design

  • @maggysantana3878
    @maggysantana3878 2 роки тому +3

    Just looking it few time and I don’t understand where you get the 350knm and the 300 Knm... from where you get the 4000mm ? Can you please do the example step by step... and show how you find those actor I mentioned to understand the math clear please.? Thanks.

    • @telestruct
      @telestruct 2 роки тому

      the design DL=350KN & LL=300KN are obtained from structural analysis. the selected column height of 4m is just an example.

  • @suhaibkhan7356
    @suhaibkhan7356 2 роки тому +3

    How 100 n/mmsq compressive stress assume

  • @dengineerslifevlog5534
    @dengineerslifevlog5534 3 роки тому +2

    Thanks for this topic...

  • @IvanIvanov-lo6lv
    @IvanIvanov-lo6lv 2 роки тому +2

    Please explain for 1.35 and 1.5 in design load. What do they mean, when to use them.

    • @sajadhussain6897
      @sajadhussain6897 2 роки тому

      they are used to increase the load to induce factor of safety

    • @AS-tq2mn
      @AS-tq2mn 2 роки тому

      They're safety factors used to increase the load. You use 1.35 for permanent loads (which is the weight of the structure and anything else that's part of the build up) and 1.5 for variable loads (which is the load you consider from people using the structure, or any other load that comes and goes/isn't constant like snow).

  • @jacksonphillips6276
    @jacksonphillips6276 2 роки тому +2

    Great Channel.

  • @Kom-pks
    @Kom-pks 2 роки тому +1

    Hi,
    Anyone know the formula for calculating 'non-dimensional slenderness' for SS400 ?
    i seem to couldnt find it anywhere, or any keyword to search would be great too
    Thank you!

    • @cnjrq
      @cnjrq Рік тому

      Slenderness (Lambda) = (Lcr/iz)x(1/(93.9e), where e = SQRT(235/fy). Fy is yeild stress, Lcr is buckling lenggth, iz is radius of gyration in minor axix. You can follow the proceodure in my recent video, if it helps you ua-cam.com/video/udCnAM3RenQ/v-deo.html

  • @igirithankgod5395
    @igirithankgod5395 4 місяці тому

    Thank you Sir for this easy approach.
    I have my actual stress as 157N/mm^2, is the column suitable?

  • @goodmind6446
    @goodmind6446 Рік тому +1

    Thanks Sir ! want to see video on stability analysis and design of steel structure.

    • @cnjrq
      @cnjrq Рік тому

      I have lecture number 23 to 26 planned for stability analysis of steel buildings. I'm on lecture 10 at the moment and you'll see three vidoes per week uploaded. Please feel free to follow this playlist ua-cam.com/play/PLOQ_D0oq27oCKwuVHk-mgE0SRIGpOpSVu.html

  • @saddammb5633
    @saddammb5633 3 роки тому +5

    How did you consider 100 N/MM2 as compressive stress?

    • @Kal-El_000
      @Kal-El_000 2 роки тому

      That was initial trial stress

    • @burhanalibaig2533
      @burhanalibaig2533 2 роки тому

      @@Kal-El_000 which book can i refer to for this calculations?

  • @gulfadventurevlogs8054
    @gulfadventurevlogs8054 9 місяців тому

    Thanks. Great Explanation. easy to understand. great job.

  • @ashleyrandall6582
    @ashleyrandall6582 Рік тому

    The 203 x 203 x 46 works. However can anyone tell me which codes this example is going according to ?

  • @emmadavies7434
    @emmadavies7434 3 роки тому +1

    Great topic guys well done!.one of the most easiest ways I've ever come across cheers!.

  • @user-ov4dw3yr5d
    @user-ov4dw3yr5d Рік тому

    If I may request a vlog for alum. Curtain wall and steel brackets structural calcs.? Thanks in advance.

  • @Beginner2Creator
    @Beginner2Creator 8 місяців тому

    Great topic : let me ask you, what about slenderness more than 3 ?

  • @ashutoshsuthar3753
    @ashutoshsuthar3753 Рік тому

    So core topics, please make video regarding design of crane grider on which the crab travels

  • @youubik
    @youubik 2 роки тому

    Just throw in that wacking great safety factor at the end and its doesn't matter what you calculate it to

  • @andreipopovcean9494
    @andreipopovcean9494 11 місяців тому

    Thanks! This is one of the most understable and practical engineering channel on UA-cam.

  • @harigovind2968
    @harigovind2968 Рік тому

    can u make a video on design of inclined cantilever columns

  • @user-ov4dw3yr5d
    @user-ov4dw3yr5d Рік тому

    Thank you for all you very informative videos. 👍

  • @vinothkumar-qq1gf
    @vinothkumar-qq1gf 2 роки тому

    As per 203 x 203 x 46Kg channel I got an actual stress value is 55.90 N/mm2. Is it correct?

  • @zakwanabo9265
    @zakwanabo9265 Рік тому

    Thank you very much

  • @victorgetsbetter
    @victorgetsbetter Рік тому

    here right on time 😂

  • @Pgan803
    @Pgan803 Місяць тому

    Excellent

  • @nadinbu257
    @nadinbu257 3 місяці тому

    thank you

  • @nirshunarayanyadav5297
    @nirshunarayanyadav5297 2 роки тому

    Very nice explanation

  • @sakally6392
    @sakally6392 7 місяців тому

    cool

  • @vesaltorabi9
    @vesaltorabi9 2 роки тому

    You are amazing!!

  • @dopareel
    @dopareel 11 місяців тому

    nice

  • @unitvector-dq1gb
    @unitvector-dq1gb Рік тому

    Trying 203×203×46 as you ask :
    This had properties,
    A = 58.8 cm
    i ( radius of gyration) = 5.11 cm
    The yield stress (fy) for this type of steel = 275 Mpa or N/mm² , it's the same.
    And the effective length is 4 m or *4000mm
    • Non-dimensional slenderness of the section is L/86i
    So 4000mm/86×5.11×10mm = 0.91
    • The reduction factor X from the curve is approximately 0.68
    • The buckling stress is : X × fy
    0.68×275= 187Mpa
    • Actual strees is :
    Design load/ Area of section
    922.5×10³ N / 58.8×10² mm
    = 156.9 Mpa < 187 Mpa ✓ok
    Susceptive to correct .

  • @bkingtz1
    @bkingtz1 Рік тому

    Who will help me calculate what type of columns and beams etc I need to make 7.5m L x 6m w and 4.5m H, cover/garage for my car lift?
    I live in country where there is snow, also no other weight on the roof except snow. I am just going to cover it with thermo panels.
    And what is necessary for column foundation (concrete and rebar etc type and spec)

    • @hudumasaud8295
      @hudumasaud8295 Рік тому

      As an engineer, do it first. Then submit for vetting

  • @bkingtz1
    @bkingtz1 Рік тому

    My 🧠 hurts 😵‍💫