I am currently using Pow keepr 1230. But now I realize that I have set all the data wrongly, so please how can I reset my PowMr MPPT Solar Charger to its previous state? Thank you for explaining
Is there any option or key combination to reset the whole settings? I think I have configured something wrong and now it's saying E-11 and preventing me from entering the menu. So if there's any option to setup the whole thing from the very beginning?
Hi I have a newer version 30A with MPPT in the middle display. Can you show the video of the newest version of Powmr Keeper 20-40A MPPT Solar Charger Controller please! Thanks.
@@PowmrSolar PowMr Keeper 30A MPPT Charge Controller does not loop display. It just show the battery Voltage. The Logo MPPT in the middle like 60A! Did I buy the real one or the fake one? Thanks.
Not recognising solar PV input, checked panel, cables and connectors and they are working fine. But no sun or solar symbol is showing. Running a powmr pow keeper 1240.
@@PowmrSolar Не хватает подробной инструкции настройки под 8S8P. хорошо бы видео по настройке такой конфигурации. Применяемый акб пересобранный Nissan Leaf.
The battery(GEL) type can use the system default setting UB00, or you can set the 12V or 24V system according to the battery connected to it. 12V selects UB01, 24V selects UB02.
E11: battery low voltage protection. If the battery voltage is higher than 12V, please disconnect all wires and reconnect them. Then please connect the battery first and then the solar panel.
@@PowmrSolar how to solve that situation i cant change the setting of the controler due to that e-11 thing it keeps poping out on the screen please do make video on how to solve that problem😥😥
Доброго вечора, підкажить будь ласка як скінуть до заводських налаштувань. Або оновити прошивку
Please send your questions to this email: support@powmr.com.
can you do some setup for 100ah gel battery?
OK.
Can handle 100wattsX4 panel parallel conection?
Should do mate, very high max PV input voltage compared to other units
can you send the video how to set-up the new version pow-keeper1220?
Hello, kindly check the link:ua-cam.com/video/n8G9dixa16U/v-deo.html
Lifepo4 battery canot be adjust to float charging to 13.6v I wonder if 13.8v float charging canot harm the Lifepo4 battery?
I have 1220 1.7V model do you have a latest user manual? I can't use my powkeepee properly because of lack manual. Thanks
May I know what specific problems did you encounter during use? Please send to this email: support@powmr.com with the product label.
I am currently using Pow keepr 1230. But now I realize that I have set all the data wrongly, so please how can I reset my PowMr MPPT Solar Charger to its previous state? Thank you for explaining
Please send your problems to this email: support@powmr.com
What is the bulk charging voltage, Absorption charging voltage and float charging for 12 flooded lead acid tubular plate solar battery?
Please send your questions to this email: support@powmr.com.
How to monitor current amperage of PV and aggregated amp?
Currently, real-time PV charging current data cannot be displayed, only total charging power data can be displayed.
hi. I buy this product. and have a error. e-11 in manual not say anything
Same here bro
Hi, E11: battery low voltage protection.
@@charlesgayon8738 Hi, E11: battery low voltage protection.
Is nmc 7s 24v battery supported?
Yes, you can select user mode. It is best to use lead-acid batteries and lithium batteries if possible.
Is there any option or key combination to reset the whole settings?
I think I have configured something wrong and now it's saying E-11 and preventing me from entering the menu.
So if there's any option to setup the whole thing from the very beginning?
E11: 12V system battery low voltage protection.
Hi I have a newer version 30A with MPPT in the middle display. Can you show the video of the newest version of Powmr Keeper 20-40A MPPT Solar Charger Controller please! Thanks.
Please stay tuned and we will arrange it later.
@@PowmrSolar PowMr Keeper 30A MPPT Charge Controller does not loop display. It just show the battery Voltage. The Logo MPPT in the middle like 60A! Did I buy the real one or the fake one? Thanks.
@@01lovemusic01 Hi, please send us your order number.
kindly check the link:
ua-cam.com/video/n8G9dixa16U/v-deo.html
What are the bulk and float voltages for 12v lithium battery ub11? Can't find it in the manual or anywhere else!
Bulk charge: 14.4V-14.6V Float charge: 13.8V
Tengo este contralador del vídeo y marca e 11 que herror es
@@edgararmandoguerreroterron7225 it means low voltage error, you must first charge your battery to >11V
Not recognising solar PV input, checked panel, cables and connectors and they are working fine. But no sun or solar symbol is showing. Running a powmr pow keeper 1240.
Can you show us by a video?
@@PowmrSolar yea, I have sent pictures and details on AliExpress powmr solar store
I have 18650 lithium ion battery in 12v. How to set it using your mpppt 20 amps?
Kindly send your problems to this email: support@powmr.com
Setting parameters lithium-ion 18660
ua-cam.com/video/Doy_e-U7GEE/v-deo.htmlsi=51K1pSw0_diqXSjd
How I can buy. 30Amp
From Bangladesh
Please join the local FB group: facebook.com/groups/424244213409576
Здравствуйте. Он работает с литием 8s ,?
Yes.
@@PowmrSolar Не хватает подробной инструкции настройки под 8S8P. хорошо бы видео по настройке такой конфигурации. Применяемый акб пересобранный Nissan Leaf.
May keeper 40ah show charging icon but not charging what could be the problem?thanks
Please send your problems to this email: support@powmr.com
i got e12 error and
what is the charge voltage for 25.6 lifepo4 battery?
Hi, please send your problem this email: support@powmr.com.
Hi! Can you share all code of list? For example I looking for any information about E16.
E16: PV input overvoltage protection
@@PowmrSolar hi. Can you share all of code list?
@@michalokocim E11: 12V system battery low voltage protection, E12: battery overvoltage protection, E13: overload protection, E14: load short circuit protection, E15: controller overheat protection, E16: PV input overvoltage protection, E21: 24V system battery low voltage Protect.
If i set it exactly on sld type the low voltage disconnect is unchangeable which is 10.8
My battery is sealed lead acid is it possible to use the settings Usermode 1 my mppt is powmr 20ampere only
kindly send us the model number. POW-Keeper1220? Yes, you can.
i buy a new one 20Amper powmr i want to now how to set up?😍
I buy your product and now have E-21 error. what happen?
Kindly send us your model number?
pow -keeper 1220
thanks
How to set up for gel type battery?
The battery(GEL) type can use the system default setting UB00, or you can set the 12V or 24V system according to the battery connected to it. 12V selects UB01, 24V selects UB02.
Why it stop charging when perfect sun and battery not full
Can you be more specific?
Lo he comprado y me da ERROR E-11. No puedo configurarlo porque se apaga y se enciende cada 30 segundos 😢
E11: battery low voltage protection. If the battery voltage is higher than 12V, please disconnect all wires and reconnect them. Then please connect the battery first and then the solar panel.
What happen E 11? How to solve this?
E11: battery low voltage protection.
pow keeper1220 version
How to set the parameters of lithium ion 18650 battery?
When using lithium batteries, please set the system voltage first, and then set
the corresponding battery type (see P8-3.8/3.9)
What kind of battery type?the available type of lithium battery is lithium iron phospate 12 /24 volts?18650 is lithium ion.
Setting parameters for lithium-ion 18650
ua-cam.com/video/Doy_e-U7GEE/v-deo.htmlsi=51K1pSw0_diqXSjd
hi..I hv a new pow-keeper1230 which has different from your demo display...could you load the demo for the new version of powkeeper 1230...
Please stay tuned and we will arrange it.
Need some help i got E-11 erorror
Hi, E11: battery low voltage protection.
@@PowmrSolar how to solve that situation i cant change the setting of the controler due to that e-11 thing it keeps poping out on the screen please do make video on how to solve that problem😥😥
@@charlesgayon8738 how many volts is your battery?
@@PowmrSolar 12.8v
@@charlesgayon8738 May I know what type is your battery?
What is code error: E-11?
Hi, E11: battery low voltage protection.
it's hard to set-up
new model
ok i want to know how change 10.8 low voltage protection
Change type of battery on USER. Then you can change.