Full Reinforcement details for 3 Storey House | 3 मंजिला घर में सरिया क्या देना है? Steel- 3 Storey
Вставка
- Опубліковано 6 жов 2024
- 3 मंजिला घर में सरिया क्या देना है?
---------
Top Most Video Playlist
1. House Construction Steps (घर बनाने का तरीका)
• House Construction Steps
2. Estimation and Costing of Construction Work (खर्च निकालना सीखिए)
• Estimation and Costing...
3. Construction Cost of House (घर बनाने में कितना खर्च होगा)
• Construction Cost of H...
4. House Plan / Ghar Ka Naksha (घर का नक्शा)
• House Plan / Ghar Ka N...
5. Walk through of House / Ghar ki sair (घर बनाने के बाद कैसा दिखेगा?)
• Walk through of House ...
6. Civil Engineering Basic Knowledge (साइट से जुड़ी कुछ महत्वपूर्ण जानकारी)
• Civil Engineering Basi...
7. Basic Knowledge of House Construction (घर बनाने से जुड़ी महत्वपूर्ण जानकारी)
• Basic Knowledge of Hou...
.
.
Contact Details:
WhatsApp:- +91- 9523101369 (Call 5PM-8PM, Monday to Saturday)
Email ID:- civilengineer.deepakkumar18@gmail.com
Telegram: t.me/erdeepaksir
Facebook page: / er3deepak4kumar5
Instagram: / er.deepak4kumar5
Twitter: / erdeepak4kumar5
----------
Join my Channel Membership
/ @civilengineerdeepakkumar
----------
#SteelDetails #GharMeSariya #GharBananeKaTarika
Thanks
thanks for support
Thanks
आपकी दी गयी जानकारी बहुत महत्वपूर्ण है।इसके लिए आपका धन्यबाद।
बहुत-बहुत धन्यवाद आपने बहुत अच्छा समझाया
Thanku very much your Explanation
Very helpful
Teaching requure knowledge & experience.
Thanks. jai hind.
Many Many thanks for good technical information. Welcome
Deepak ji excellent information diya... 🙏🙏🙏🙏🙏
Many thanks to for good instructions , various discussion and regarding different details of building construction. Welcome
बहुत ही शानदार जानकारी दी है सर आपने बहुत बहुत धन्यवाद सर आपका
आपका लगभग सभी वीडियो देखता हूँ l अच्छी जानकारी मिलती है l
Are you great sir ❤ se bahut hi behtrin tarike se aapne explain kiye
Very valuable information given sir.if we need some guidance we will defiantly call you.
Very useful one Deepak sir. I salute you.
Headsoff.. Very Informative 👍👍👍👍👍… God Bless you and gives you lots of success in life 🙏🙏
Sir, foundation mai 12 mm steel 6" c/c mesh dene se koi problem hoga?
Please reply, request you sir 🙏
No But it should be Box Fndn not Mesh
Thank you very much for the nice tutorial. Kindly clarify the floor to roof distance of each floor. Also kindly clarify whether the building hight of 10 meters includes basement height also. Thank you.
🙏👍Thank you so much for your clarification. It is a good job from your side sir. Very good tutorial from us sir, Thank you.
Thanks and welcome
Sir very good style of description.
Thanks and welcome
Thank you sir for uploading great vidoes. Sir, column lapping par kuch videos honi chahiye.
Deepak ji aappka tarika sikane ka bhoot saral h acha laga Ab ark vidio commercial building bananai per. banaaiy. 150 suqer meter h Plot sig 8meter by 18.75 meter h Hight 35 foot esh k liye steel kirney mm ka lagaiga foundation s laker roof tak
Excellent Deepak bhaiya .....🙏🙏🙏🎉🥳🤗❤️
Thanks a lot for your kind knowledge. What will be the cost of G-2.
About 30-35 lc,, depends upon yu area... without interior.
Thanks a lot sir for giving valuable information,very nice god bless you keep continue in public interest 🙏🙏
Thankyou sir!
Good information ❤❤
Sir ak video banaye jaha par .... A to Z ... Information hoga .... Jesa Field check , various test , then column beam size, distance between two columns, next .... Which side door, which side window , ..... Pura ka Steel calculation, 2 storey building ka .... Total expenditure of the building ....... Matlab sob kuch ........ Hoga video me .😊 Manta hu video lengthy hoga ... Lekin sir ak pura video banaye ..... Nehi to part part krk v bana sakte ....... please sir 😊😊❤❤
Thank you sir I was looking for this...
Sir, very useful information, Thank you Boss,
What is the cost of the 3 floor building of 1200 sq ft in each floor in 2022
For normal construction It will be cost u approx 30-35Lakh with out interior and depends on ur area too. 🤑🤑
Provide 6no 16mm bars in Coloums if required another floor can be added instead of 4-16mm & 2-12mm
Excellent information Sir
Thank you so much, your explanation is always extraordinary ❤️
Thanks for explanation is an extraordinary
Good information sir 🙏
Thanks sir 🙏 very informative video.
Thanks a lot
A long Awaited Video Thank you Nice Information
Most welcome
Stair me thoda mismatched ho gaya,but the video is so informative in less time.thanks...
Excellent sir❤️
Thanks.
बहुत अच्छा बताएं सर,मै 4 stories building में अभी कुरसी,पिलर ,छत देना देना चाहता हूँ। किया खर्च आयगा सर।
Nice deepakji doing well. I regularly watch ur video. Keep it up. May i knw ur consultancy fee
Not sufficient bar has been provided... It will require more if we consider seismic force, number of bar depend on shape of building also like rectangular, square etc..
I like your valuable suggestion.
Jai hind ke sena.
Many many thanks.
सर अगर दो कॉलम की बीच की दूरी सिर्फ 7-7 फिट है तो कॉलम क्या 9× 12 का दे सकते हैं 6 सरिया के साथ❤
क्या plinth beam में सिर्फ 4 सरिया देना है ?
Plinth me kam sariya bataya deepak bhai ne... 9×15 ka beam kam se kam or 4 bar 16 k n 2 bar 12 ka
Nice job sir . Agar column to column distance 20 feet hai to column size and rainforcment kya de isme confused hu
Thanks sir
Welcome
Thanks
Sir 12 mm ke 8 rod par coloun chalega kaya.. G+2 Floor
Very good video.Thanks
Thank you too
Bahut badiya bhai
Sir you are the best
Good vidio
Sir thanks
Due to mis alignment of column while creating ground floor we have to provide joggle to all the steel of column for the first floor of about 1 inch will it hamper for three storage???
If Your 1st floor column is Already miss aligned then it will creat problem.
-Joggle is not the issue for construction its the safe way.
Namaste sir
Mera ghr 30×30 h . AV ek majil hi bnaye hn
3 floor banana chahte hn.
Prob ye h ki only corner ke 4 columns me hi 6 pcs saria dala h Baaji ke columns me 4 pcs saria h .
Ab kya kare ki 3 floor ghr bna sake .
Sir G+1 k liye bhi aisa video chahiye
Tnx
Very useful information,thank u
Welcome 😊
CIVIL ENG. Deeoak kumarjee thank u
I appriciate your transparant conception on the subjective knowledge I thank u once again
for your distribution of knowledge
& mature experience.
Pl. respond me if u don't like to
conieve my request as younger
brother as I am originally of maharajgang dist. Presently in
Assam and also in meghalaya
but I intend to settle in noth bengal.
Pl. share your experience if I send
my land skatch. Pl. share your rate
if I need your valuable suggestio.
Jai hind.
Sir agar koi architect plinth beam me 10 mm ka 4 sariya diya ho vo bhi 3 manjila ke liye to kya kare sir open slab h
All reinforcements will same for second and third floor or different
4 corner me 9×16 4 sariya 16 mm.midle me 12 mm ka diya hai lekin sirf 4 rov kone me diya hai bich me 12 mm ka sariya diya thik hai 3 floor ke liye sir jiii.
Very nice explanation sir 🙏
Keep watching
sir, mera footing 12mm 500D or beam 12mm 500D 10×10 ka hai kya 3 manjila banana uchit rahega?
Good information
Thanks
Thank you very much
Sir 3 manjil ghar ka footing me sariya 16mm ka dena hai kya
Fly ash bricks se( g+1) ghar Bana sakte hain, pluster Kitna sal acha raita hain
Very important nd useful information about steel reinforcement for three storey house.Thanks👍
Most welcome 😊
Great help thank you sir
Always welcome
Deepak bhai , mera ghar ka room 13x13 hai kya chhat dhalai me bich me bim dene ki jarurat hai ?
Thenk
Sir future me top floor banana hai to coloum ka reinforcement top floor me kitana length chodenge .
Or use cast karna hai ya fir wasehi chod dena Hai kyoki 2 se 3 sal bad jab column extend karenge to lapping denahoga?
2-3 yr keliye Aap Use Plastic Se cover kar sakte ho,, Aur length 1.2 Mtr rakho minimum.
Very good👍 engineer
My mechanical engineer
Good information💯💯💯
Thanks for watching
Very good advice, please send me approximate estimate G3 building 2400 square feet North East Assam sibsagar district
Sir Only Ek Ground Floor vedio banaia na
Excellent knowledge sir
Thanks and welcome
Thank you so much sir
Most welcome
Footing ke liye mesh jaali me 16 mm ke badle 12 mm ka steel bar use kiya jaa sakta hai ?
2&3 floor me column rainforcement same dena hoga kya
Yes
Good
Kya 2yr pehle k video me bataya tha k 3 manjila ghar k beam 12×16 aur reinforsment 16mm ka 4 saria yaha beam k a size 9×12aur reinforcement 12mm ka 2 16mm ka 2
आज कल डबा फुटिंग भी जो pcc मे भी कॉलम मे भीम देत है अच्छा है क्या सर
Sir, my plot is 4.5 ft below road level and i have keep my house floor 2.5ft above present road level. In this case what should be the depth of footing from present ground level.
Sir for 1 story building roof beam size 9*9 , kya es main slab thickness including hai ya nahi hai ?
Sir,3 monjila ghar me 1 colum ka kitna khorcha hota hai? Please video bana dije sir.
Thank,
Sir G+3 ka bhi aise detail me videos banaye please
Thanks sir
G+3ka jaankari de.
Which cement is best for foundation opc 53 or ppc.
Since ppc is less water permissible and resistant to chemical attack ,can we use ppc.
PPC,, for hole making is best.. Remember proper curing is there.
Thank you Very much.
Welcome 😊
Agar ecentric footing dena ho to steel details kya hoga ??
Aur roof beam me to curtail bar dena hai kya plinth beam me bhi curtail bar dena hai kya??
Contact civil engineer near by u.
Sir roof beam ko thoda aur explain kr dete🙏
Sir, I want detail drawing for roof reinforcement & replacement of 10 MMS and 8mm steel bar.
ua-cam.com/video/F6m7MQOE0IM/v-deo.html
Can we use 12 mm column rod in second floor in 3 story building
Yes but add extra reinforcement. 🤠
sir, 20*40 sqf mey 2 bhk, bana rahey hai kya ismey tie been mey 2 saria 12mm or 2 saria nichey 16mm behtar hoga 3 lenter daal rahey hai
Sir, can it be used for G+4 story structure.....??
Can we use 2 - 16 mm in top and 2- 12mm in bottom in roof beam for 3 storage...
Bottom bar should be of higher dia in Case of tension Member.
And if your floor loading is less then it is ok. And If u construct wall and column together and then provide beam there the wall can carry some load it depends upon ur construction type. It will reduce ur room size. 😁
Deepak ji main ek ghar banwa raha but engineer sahab ne foundation layout kuchh jyada hi high rise building ka de diya hai kya aap please check kar paynge?
ok
Ye commercial building k liye ya house k liye
Sir mera building ka size h breath 32 ft length 45 ft. h, total 12 column hai ,Futting mesh 2.5 ft hai aur column me 16mm ka 4, 12 mm ka 4and ring ka size 7" Inch h. 4 ft depth h, uske baad 5 to 6 feet earth filling kiya hua hai
Pleanth level tak kaam ho chuka hai target sir 3rd floor tak ka hai
Feb 25 me kaam suru karna hai . Sir please mujhe guide kare