Understanding and recognising UK electrical earthing arrangements - inspection and testing & Design

Поділитися
Вставка
  • Опубліковано 29 сер 2024
  • Hello and welcome to this video on earthing arrangements by Adrian Davey from Pure Electrical training.
    In this video, I help you identify the three main earthing arrangements in the UK, and the types of cable used to supply them.
    I then go on to discuss how you select the correct size earthing conductor and which regulations apply, as well as a handy table to save you from having to calculate the size using the adiabatic equation.
    This video counts as CPD and off-the-job training.
    As always, please like, share, and subscribe so that everyone can benefit from the information contained within.
    Take care
    Adrian

КОМЕНТАРІ • 24

  • @sergiofernandez3725
    @sergiofernandez3725 Рік тому +3

    Nice and informative. Keep it going Adrian.

  • @AviKhali
    @AviKhali 9 місяців тому +1

    This is just what I needed. Keep on making more please

  • @marcushall8432
    @marcushall8432 Рік тому +2

    Great work - Clean and concise.

  • @markjamesgoddard2247
    @markjamesgoddard2247 Рік тому +1

    Brilliant fair play.. sterling work.. 👌Thanks man 👍

  • @williammartinculleton5875
    @williammartinculleton5875 Рік тому +1

    Great for a little revision,thank you

  • @michaelcotton9231
    @michaelcotton9231 Рік тому +1

    Great Video. Thank you 👍🏻

  • @AA-op8mu
    @AA-op8mu Рік тому +2

    Hi Adrian. Can you make a video showing the different formulas for bending containment at different angles using different size containment i.e metal tray and also mark back measurements for bending conduit at 20 and 25mm tube. I

    • @Pure_electrical_training
      @Pure_electrical_training  Рік тому

      It’s on my list to do, but it’s way down the list

    • @AA-op8mu
      @AA-op8mu Рік тому

      @@Pure_electrical_training as long as its on ur list im happy and thanks for your great work

  • @gezimmarku1348
    @gezimmarku1348 5 місяців тому

    Great Video,
    If you can make a video filling NET electrical installation certificate (EIC) for AM2
    Thank You

  • @geraldelwood9660
    @geraldelwood9660 Рік тому +1

    Thanks for your video. I love to pick up new bits of info each day.
    But ... At 7.35 you seem to be implying that on a TT supply, an RCD is required IF the Ze is >200 ohms. Max Disconnection time for circuits

    • @Pure_electrical_training
      @Pure_electrical_training  Рік тому

      Thank you for the feedback 🙏
      Apologies, I didn’t mean to imply that, which is why I spoke through the RCD tables, Zs and relationship to ohm’s law

    • @geraldelwood9660
      @geraldelwood9660 Рік тому

      Sorry - correction to disconnection time in my comment above. Just realised I stuck an extra 0 in. Should of course be 0.2 secs not 0.02.

  • @linossinkala7840
    @linossinkala7840 Рік тому +1

    Goodwork

  • @Rossisearle
    @Rossisearle Рік тому +1

    hello adrian would i be able to get copy of this so i can print for personal use? i have to say this is one of best video on earth arrangments, amazing work

    • @Pure_electrical_training
      @Pure_electrical_training  Рік тому

      Thank you so much 🤗
      What did you want a copy of, could you screen shot the bits you want?

    • @Rossisearle
      @Rossisearle Рік тому

      @@Pure_electrical_training all of it...