Running a sewer line part 2 Piping

Поділитися
Вставка

КОМЕНТАРІ • 123

  • @Pitbulls_and_Plumbing
    @Pitbulls_and_Plumbing 2 роки тому +20

    I love how you go step by step, start to finish...very helpful when i get into a situation that im not sure of how to do. Thank you for your vids. Keep em coming.

  • @MLDIYSH
    @MLDIYSH Рік тому +7

    1/8 pitch is what we use down here. 1/4 is a lot of slope. Listened to another guy and he said 1/2 slope - wow! The end was sloppy-especially that cut. All the measuring and the end was HIGH.

  • @wyleaziz5050
    @wyleaziz5050 2 роки тому +36

    To take the efforts videotaping and telling the installation details is not easy. I really wish you get more subscribers for the amazing work you do.

  • @na2305
    @na2305 Рік тому +5

    This was so well done. Very informative as it helps me understand everything when it comes to those of us buying a lot to build on.

  • @scottification4it
    @scottification4it Рік тому +3

    thanks for the videos! cant believe i never thought of adding string to the old primer/glue combo for a handle.

  • @buddyrevell511
    @buddyrevell511 9 днів тому +1

    Fantastic info for a novice builder like me... thank you!

  • @tsetendorjee9040
    @tsetendorjee9040 Рік тому +3

    We love your Plumbing Solutions and thank you very much !!!

  • @jasimal6945
    @jasimal6945 2 роки тому +3

    Good job! Thanks for sharing your experience.

  • @danielhuynh01
    @danielhuynh01 2 роки тому +4

    Thank you for taking the time to make the video, very informative. Thank you.

  • @hoopdndanucd
    @hoopdndanucd 10 місяців тому +2

    Thanks for taking the time to show us step by step.

  • @objuan6
    @objuan6 10 місяців тому +1

    video been around for a couple seasons, still
    a great help. Thanks, well done.

  • @rusosure7
    @rusosure7 6 місяців тому +1

    And here I was thinking 1/4" drop was mandatory for 2" and smaller, and 1/8" was acceptable for 3" and larger.
    Guess I'll have to research this again.
    Thank you for your video.

  • @JustJanitor
    @JustJanitor Рік тому +7

    I really appreciate the effort that went into making these videos.

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому +1

      Thank you ... we use these videos for in house training , we figured why not share them .

  • @robertvazquez2571
    @robertvazquez2571 2 роки тому +4

    Thanks for the video. Aren’t many out there for this work.

  • @workingshlub8861
    @workingshlub8861 2 роки тому +3

    good info..never even thought of the copper wire to find the line later with a locator..

  • @alusinemthoronka4240
    @alusinemthoronka4240 Рік тому +3

    Thank you for teaching us
    You make us to understand easily

  • @VtuberGodai
    @VtuberGodai 2 роки тому +2

    excellent video!!!! very clear

  • @veronisesido3979
    @veronisesido3979 2 роки тому +2

    Great video.Thanks

  • @hykeemrobinson8898
    @hykeemrobinson8898 2 роки тому +2

    Thanks bro I learned a lot

  • @SubaruAficionado
    @SubaruAficionado 9 місяців тому +1

    Thx for the very informative video! Question: what is the easiest/best way to create the manhole and cover for the backflow device?

  • @buddyrevell511
    @buddyrevell511 9 днів тому +1

    For the people criticizing: where are YOUR videos showing how it's done? That's what I thought.

  • @seanogrady2629
    @seanogrady2629 2 місяці тому +1

    Nice video

  • @inquietoazul21
    @inquietoazul21 Рік тому +3

    Using the sanitary tee is a problem when trying to do a camera inspection and can also makes it hard to drive the sewer cable into . Good thing there is a back flow 😅

  • @andranika6203
    @andranika6203 4 місяці тому +1

    Thanks for your explanation 👍

  • @jpjp9111
    @jpjp9111 Рік тому +1

    Do you have any advice on replacing vents?

  • @MrRain-hk4zi
    @MrRain-hk4zi Рік тому +2

    Nicely done.

  • @AngelMalakim
    @AngelMalakim 6 місяців тому +1

    dude, thanks for making this video! you da man!

  • @derrickcollett1561
    @derrickcollett1561 2 роки тому +3

    Why not use the long sweep 90 tee for clean out? Just curious…

  • @whitetiger8652
    @whitetiger8652 5 місяців тому

    Great video. Would you happen to know when it became code for homes to install a clean out?

  • @veryslyfox
    @veryslyfox Рік тому +2

    it's better to tape the tracer wire to the bottom of the pipe so it doesn't get struck by digging equipment

  • @janparzybok162
    @janparzybok162 11 місяців тому +1

    Excellent!

  • @retiredperson4054
    @retiredperson4054 6 місяців тому +1

    ? We will having a septic system with our new build --- Should we include a backwater valve between the inlet of the septic tank and where the drain waste line exits the basement? Will we also need a clean-out along with the back water valve? The one thing we want to add here -- is that the septic leach field will be above the septic tank location by about 40 feet in elevation -- and the system will be a "dosing" system with a sewage pump in a separate chamber which will have it's own backwater valve at the discharge side of the pump chamber. Your answer will be much appreciated. Great VIDEO by the way!

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  6 місяців тому +2

      You don't need a backwater valve but i would put a cleanout on it

    • @retiredperson4054
      @retiredperson4054 6 місяців тому +1

      @@PlumbingSolutionsLLC Thank you for the answer! Your videos are great! Keep sharing your experiences and knowledge. RP

    • @retiredperson4054
      @retiredperson4054 6 місяців тому +1

      @@PlumbingSolutionsLLC As I have researched long for information on whether a planned basement mechanical room floor drain installation requires a VENT.... I believe the Tennessee Code I need to follow said that Floor Drains do not to be vented? What is your thought?

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  6 місяців тому +2

      it needs to be vented and it needs a trap primer

    • @retiredperson4054
      @retiredperson4054 6 місяців тому +1

      OK Thanks again @@PlumbingSolutionsLLC

  • @budgetingstrategies6240
    @budgetingstrategies6240 Рік тому +2

    West Virginia sewer dig depth, does anyone know? Thanks in advance and love the video. Subscribed.

  • @pierre-richardbeaubrun5063
    @pierre-richardbeaubrun5063 Рік тому +1

    Great video

  • @affordabledesertliving3487
    @affordabledesertliving3487 Рік тому +2

    any disadvantage to just running the 4" schedule 40 right up into the house? As opposed to the 3" PVC?

  • @eddierivera8274
    @eddierivera8274 Рік тому +2

    is the backwater valve intended to be installed near the foundation in a yard box with 24/7 access (given the screw top)? I don't need one by code but it seems like a handy way to further future proof my new mainline. Is the main sacrifice that the door needs to be removed if you snake it in the reverse direction?

    • @junioraguayo8574
      @junioraguayo8574 Рік тому

      Yes just remove flapper inside the backflow valve n snake backwards but if your snaking towards a tank or manhole u dont need to just make sure u go right direction with machine/cable

  • @brandonjensen5292
    @brandonjensen5292 Рік тому +2

    Nice work

  • @craigcoloradodude
    @craigcoloradodude 2 роки тому +8

    At 23:50 the primering and gluing after the valve fitting look at your video you did not even glue the upslope side of the pipe you put in the fitting. You did primer it kind of but no glue! Watching your gluing and priming very weak, I would love to see your pressure test and see how many of the connections leak. And not sure where your located but where I work auto fail for using a san t on its back for the cleanout. A wye and 45 for a cleanout. But still a informative vid, thank you.

    • @veryslyfox
      @veryslyfox Рік тому +2

      since when are sewer lines pressurized?

    • @SergioPena20
      @SergioPena20 10 місяців тому

      @@veryslyfoxthey’re a part of the inspection. No pressure test, you don’t pass the inspection.

  • @mikepayne1851
    @mikepayne1851 4 місяці тому +1

    Thanks for the vid. Sch 40 material or what?

  • @bills6946
    @bills6946 8 місяців тому +1

    He didn’t clean the inside of any cuts he made. Burrs are future clogs. A little stingy with the primer and glue for my standards. We don’t use a torpedo level. We use a 4 foot level for pitch

  • @ChristianGutierrez
    @ChristianGutierrez 7 днів тому

    Superb video ❤

  • @blancavr1
    @blancavr1 Рік тому

    What was the wire for, also that part whete you installed the reducer.

  • @mcintosh63676
    @mcintosh63676 Рік тому +1

    Absolutely correct about laying the sanitary T on its back

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому +1

      The inspectors let them do it , I guess it's cause it's just a clean out and there is no waste traveling down it.

    • @bradhaenitsch1145
      @bradhaenitsch1145 Рік тому

      Basic plumbing folks just because the so called inspector is ok with it right. You’ll be augering that line out once a month only on vents and especially never below the hard gray stuff

  • @karlloper3838
    @karlloper3838 Рік тому +1

    How many 45 's can you have in the line to the septic tank? Do you have to use 4" if no code or inspection??

    • @bills6946
      @bills6946 8 місяців тому +1

      “No code” means install according to the IBC.

  • @manstersr
    @manstersr Рік тому

    Good job, the only question you didn't answer is, what's the tracer wire for? Well, one another, what are the permit requirements if you are just a homeowner replacing old pipe?

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому +1

      The wire is for locating it later. Permitting is going to change from state to state, county to county . Most areas don't require a permit to repair or replace existing. but, you might want to check.

  • @TheArthead
    @TheArthead 2 роки тому +1

    Thanks , man

  • @tonyfat2458
    @tonyfat2458 2 роки тому +2

    Good video

  • @jiujitsujim
    @jiujitsujim 2 роки тому

    Is this setup good for a north Michigan new build? Thx

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  2 роки тому +1

      I don't know we don't get must snow in SC, you will have to check your local codes

  • @ChrisDembinsky
    @ChrisDembinsky 2 роки тому +1

    Why can't you run the waterline next to the SDR 35 pipe? Also, If you had a 150' run to make would you still use schedule 40 PVC? I'll be putting it in ground that's likely to eventually have lots of tree roots. 13:29

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  2 роки тому +4

      We use sch 40 to prevent bellies . and water lines next to sewer line It's all code stuff, they don't want thin wall sewer to be next to the water. In case there is a breakage.

    • @briankohlenberg
      @briankohlenberg 2 роки тому +1

      @@PlumbingSolutionsLLC Why not ABS blank ?

  • @Atr42Greasemonkey
    @Atr42Greasemonkey Рік тому +1

    I may be wrong but thought you had to give the primer 15 seconds before applying the glue. Also wouldn't you normally dry fit and mark the connections for fit ,then glue? Your trying to level the fittings with the glue already bonding..Im not a plumber by trade but have watch a 1000 hours of video..lol

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому +1

      everybody does it a little different , never dry fit , the fitting will get stuck together and you won't get them apart.

  • @heyyo2696
    @heyyo2696 Рік тому

    What is the purpose of the light green pipe inserted over the white pipe. Can i use plumbing
    strofoam wrap over the white pipe when passing under concrete footing? What is the difference bet. white and black and light green pipe. Thanks.

  • @alboboy85
    @alboboy85 2 роки тому +2

    Is the pitch for the 4 inch pipe supposed to be 1/8 or 1/4?

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  2 роки тому +3

      either one, just stay in between the two

    • @medmuscle
      @medmuscle 2 роки тому +5

      According to code, 1/8" is ok for 4" pipe, but many plumbers will just do everything at 1/4" since smaller pipes require the steeper 1/4" pitch due to being more restrictive because of the smaller size. For example, your 2" pipe must have 1/4" pitch.

  • @Lishasenitirigloria2635
    @Lishasenitirigloria2635 2 роки тому +2

    In Fiji backwater valve isn't compulsory 🤦🏼‍♀️

  • @meljenkins1016
    @meljenkins1016 2 роки тому

    Whenever you mess up, your always in a hurry.

  • @ruedasmoises
    @ruedasmoises Рік тому

    I almost see you not spin that reducer I was getting nervous but you did it at the end always twist and hold for about 2 to 3 seconds it only twist one way

  • @marqueemark5917
    @marqueemark5917 Рік тому +2

    Where I am from no san tee on its back! Combo's wye 45!

  • @jeremiahtbarmes
    @jeremiahtbarmes Рік тому

    Fyi, shake your primer brush to keep the primer from running all over the pipe.

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому +1

      Haha. the man who taught me use to sling the primer all over the ground. I thought it was a big waste.

  • @rudygallegos8559
    @rudygallegos8559 Рік тому

    What state an city you working out off?

  • @rudygallegos8559
    @rudygallegos8559 Рік тому

    Here in south Texas with heat an humidity, black shirt a no no

  • @joshcowart2446
    @joshcowart2446 2 роки тому +1

    Do y’all automatically put the backwater valve in or is this house just in a position that needs one?

  • @dannypalmer7701
    @dannypalmer7701 2 роки тому +1

    Set the drop before the glue drys

  • @CaptainHenry02
    @CaptainHenry02 2 роки тому

    Great works but I worry about your hairs to be fried up by the sun ☀️.

  • @SureShotImages
    @SureShotImages Рік тому +1

    There’s really no reason I can think of to use a sanitary tee as a cleanout instead of a wye.

  • @harveypriest3011
    @harveypriest3011 Рік тому

    What is the traser wire for

  • @beralita5466
    @beralita5466 Рік тому +1

    You better use enough primer glue.....make sure no leaks...

    • @junioraguayo8574
      @junioraguayo8574 Рік тому +1

      Unless it has lift pump the sewer line dont need primer buddy it aint pressurized it gravity fed

    • @junioraguayo8574
      @junioraguayo8574 Рік тому

      Just red hot glue

    • @rudygallegos8559
      @rudygallegos8559 Рік тому

      Yes sir primer an glue, great state of Texas

  • @edgaranaya7969
    @edgaranaya7969 2 роки тому +1

    How do you cut the pipe straight??? Tell me the trick please

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  2 роки тому +1

      lol.. I don't think there is a trick. Practice

    • @brandonk1502
      @brandonk1502 Рік тому

      @@PlumbingSolutionsLLC Chop saw. I am curious though as to gluing the joints together if you may, though. I can't seem to get my pipe to slide all the way into the the fittings so that it meets up flush with the inside edge of the pipe. I always seem to have a 1/4 inch gap and I'm worried that it will slow down my wastewater and eventually create a backup. Is that normal or am I doing something wrong? I've twisted them in and even used my full body weight and still it's the same result.

    • @brandonk1502
      @brandonk1502 Рік тому +2

      Buy a big enough chop saw to cut through the pipe. Near perfect cuts every time and minimal deburring. I bought a used miter saw for 80 bucks, it works fantastic and I've used it for all sorts of stuff.

  • @Derbyd1484
    @Derbyd1484 Рік тому +1

    black shir in the sun... no go...

  • @rudygallegos8559
    @rudygallegos8559 Рік тому +1

    Tracer wire on a sewer run, why not use camera an a sewer locator, lot easier, can see how states do plumbing different

  • @mrferris
    @mrferris 8 місяців тому

    Surprised you still have all of your fingers.😳

  • @zabizeyaee8002
    @zabizeyaee8002 2 роки тому +1

    If you only go up, why you call it reducer then?

    • @davidmize8489
      @davidmize8489 2 роки тому +1

      It’s just the product name. However it is also called a 3x4 adapter which is maybe more appropriate.

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  2 роки тому +1

      good question,,,

  • @mark_Hershey
    @mark_Hershey 2 роки тому +1

    Oh boy…

  • @dozingprankz7834
    @dozingprankz7834 Рік тому +1

    U can only go up in size never down😂☠️☠️

  • @abeltubeyou
    @abeltubeyou Рік тому +1

    How deep is sewer line in ground

    • @PlumbingSolutionsLLC
      @PlumbingSolutionsLLC  Рік тому +1

      depends on where you live. Here in SC the frost line is zero. so, it is supposed to be 18 inches deep. But, the Inspectors have never failed us for depth as long as it is under the dirt.

  • @rolandopizana7598
    @rolandopizana7598 Рік тому

    No You use A 4" Two Way Clean out Tee

  • @pilbomags488
    @pilbomags488 10 місяців тому

    That pvc pipe fits like a glove on that teal pipe NOT

  • @patrickhenry2342
    @patrickhenry2342 9 місяців тому

    When you level it to .25, how does it stay level? For example, if I push down some to get that the proper level, and it rebounds back up, what do I do? Remove that dirt?