Vapour Compression Refrigeration & Domestic Refrigerator in Tamil - Ruskin Bruce A

Поділитися
Вставка
  • Опубліковано 28 січ 2025

КОМЕНТАРІ • 24

  • @adhikesavan484
    @adhikesavan484 Рік тому +1

    Superb anna🎉

  • @mathanmathias5195
    @mathanmathias5195 2 роки тому +1

    Sir ,good explanation about vapour compression system...Thank you

  • @boysvolatile8016
    @boysvolatile8016 4 роки тому

    Bro awesome explanation please do lot more videos which is related to practical explanation

  • @Raj66666
    @Raj66666 7 місяців тому

    Best explanation sir🎉

  • @murthy6946
    @murthy6946 2 роки тому +1

    Very nice sir

  • @bharathganapathy8759
    @bharathganapathy8759 2 роки тому

    Ruskin sir..🔥🔥🔥
    Satyam clg😍😍

  • @ashokashok6819
    @ashokashok6819 3 роки тому

    Super explanation sir.......

  • @devendharans6502
    @devendharans6502 2 роки тому +1

    Nice explanation

  • @mathanmathias5195
    @mathanmathias5195 2 роки тому

    Subcooling can be measured in condensor side and superheat can be measured in Evaporator side...superheat value is shows that system performance...

  • @YoucaNShine
    @YoucaNShine 4 роки тому +2

    Waiting for this one sir🥰

  • @goldentriangletamil8310
    @goldentriangletamil8310 4 роки тому

    Dedication level 🤗🤗

  • @diwakars5791
    @diwakars5791 2 місяці тому

    Good

  • @kumarkumar-ru6eo
    @kumarkumar-ru6eo 10 місяців тому

    Super sir

  • @stanlylouis3687
    @stanlylouis3687 2 роки тому

    Refrigeration and air conditioning difference sollunga bro

  • @sethuraman.a1015
    @sethuraman.a1015 4 роки тому

    Nice speaking

  • @aloneheart9290
    @aloneheart9290 Рік тому

    Bro backla irukra screen olunga terila

  • @jayaprakashdhayalan4169
    @jayaprakashdhayalan4169 4 роки тому

    Dear sir I have one doubt sir
    Refrigerant come to outside of condenser to store Recevoir
    But the same refrigerant come to outside of Evaporater (Recevoir not here .....why ). Because 100 percentage confirm liquid to vapour not done

    • @engineeringfrombasics1825
      @engineeringfrombasics1825  4 роки тому +2

      Hi Jeyaprakash,
      when the refrigerant leaves the evaporator, as you said it doesn't get converted completely to vapour form. The compressor what we have is a vapour compressor, so it is good if the refrigerant is completely in vapour form.
      When a portion of the refrigerant is in the exit of evaporator, there are two ways to avoid entering in to the compressor.
      i) the expansion valve, which is in the form of coil is (stretched and is) made in contact with the vapour tube which exits from evaporator. by this act the liquid refrigerant towards compressor takes the heat from the liquid refrigerant which moves towards the evaporator. So the remaining refrigerant in liquid form gets converted to vapour in addition the refrigerant to evaporator is further cooled it is good as well.
      ii) There will be an accumulator in the suction line of the compressor to collect the liquid refrigerant. a filter - drier could also be fixed in the suction line of compressor.
      These are not included in the video to make it short.
      hope this clarifies the doubt.
      have great time, take care

    • @jayaprakashdhayalan4169
      @jayaprakashdhayalan4169 4 роки тому

      @@engineeringfrombasics1825 yes Sir clarified...Tq

  • @mkevin51
    @mkevin51 4 роки тому +2

    Bro unga number thaanga neenga Kanyakumari ah naanum Kanyakumari bro i need some help regarding hvac

    • @engineeringfrombasics1825
      @engineeringfrombasics1825  4 роки тому

      Hi Kevin, Yes I am also from Kanyakumari district, you can reach me at ruskinbruce@gmail.com, shall speak to you, have good time