Asslam Alaikum Faiz bhai transformer pe video bnaye jaise ki 110/ 220/380/ hai ab hamko isme se koi ek supply dena hai to utne wire me se kaise pta kre ki koan sa wire pe mera 110/220/380 ke liye koan sa wire use kre aur waise hi 12 volt/24 volt out ho rha hai to kaise pta kre ki kaon se wire se 24 volt nikal rha hai Aur kaon si wire se 12 volt nikal rha hai ispe full video banaye bhai
Assalamualaikum bht bht gusishtaaa Eid Mubarak Khush rheen hameeha Bhai system meen koi b gas apni halat kb change krti hy mtlb liquid form meen kb ati hy capillary k baad ya condenser k baad kb please bta deen
waalaikumassalam . aapko bhi. khair mubarak 🤲. 👉 suction line se compressor ne low temp. aur low pressure vapor suck kiya aur usko compressor ne compressed karke high temp. aur high pressure vapor main convert karke discharge se out kiya . ab high pressure 100% vapor condensor main in huwa condensor ne heat nekal karke 100% vapor ko 100% liquid ( high pressure liquid )main convert kar diya aur ab 100 % liquid expansion valve ( capillery , orifice , thermal txv , electronic txv..) main inter huwa aur expansion valve ne high pressure aur high temp. liquid ko low pressure aur low temp. liquid main convert karke ( 80 to 85 % liquid and 20 to 15 % flash gas / vapor ) evaporator / cooling coil main bhej diya aur ab room ki heat se ( blower air ) liquid vapor main convert ho gaya aur wahi vapor phir dobara compressor ne suck kiya aur aise ye cycle chalta rahta hai jisko refrigeration cycle bolte hain ..ummeed karta hoon aapke sawal ka jawaab mil gaya hoga 🤝 💚
R410 gas Two gas sa mil Kar Bana hata hai R32 r125 isliye ham liquid charge karta hai r410 ko ham tapap nahin kar sakte hain kyunki hamare system mein gas liquid charge kiye Hain liquid se vaparr banaa hai aur kaun sa gas Kitna release ho Gaya humko yah Nahin pata hai isliye ham 410 gas ko top up nahin kar sakte hain
Thank you brother very nice and knowledgeable.
Very useful video hai Bhai
shukriya 💚
Liquid line me inner k passs bubbles ki sound aur vibration q ati hai? Isko kesy shi kren
Bhai jo apke pss meter ha usy ksy single phase compressor chck kr skty short ha k nhi thora smjna bhai bht muskil hoti smj nhi ari
Thank you sir 💯clear
it's my pleasure 💚
Asslam Alaikum
Faiz bhai transformer pe video bnaye jaise ki 110/ 220/380/ hai ab hamko isme se koi ek supply dena hai to utne wire me se kaise pta kre ki koan sa wire pe mera 110/220/380 ke liye koan sa wire use kre aur waise hi 12 volt/24 volt out ho rha hai to kaise pta kre ki kaon se wire se 24 volt nikal rha hai Aur kaon si wire se 12 volt nikal rha hai ispe full video banaye bhai
waalaikumassalam brother.
I will try 🤝 ❤️
Assalamualaikum bht bht gusishtaaa Eid Mubarak Khush rheen hameeha Bhai system meen koi b gas apni halat kb change krti hy mtlb liquid form meen kb ati hy capillary k baad ya condenser k baad kb please bta deen
waalaikumassalam .
aapko bhi. khair mubarak 🤲.
👉 suction line se compressor ne low temp. aur low pressure vapor suck kiya aur usko compressor ne compressed karke high temp. aur high pressure vapor main convert karke discharge se out kiya . ab high pressure 100% vapor condensor main in huwa condensor ne heat nekal karke 100% vapor ko 100% liquid ( high pressure liquid )main convert kar diya aur ab 100 % liquid expansion valve ( capillery , orifice , thermal txv , electronic txv..) main inter huwa aur expansion valve ne high pressure aur high temp. liquid ko low pressure aur low temp. liquid main convert karke ( 80 to 85 % liquid and 20 to 15 % flash gas / vapor ) evaporator / cooling coil main bhej diya aur ab room ki heat se ( blower air ) liquid vapor main convert ho gaya aur wahi vapor phir dobara compressor ne suck kiya aur aise ye cycle chalta rahta hai jisko refrigeration cycle bolte hain ..ummeed karta hoon aapke sawal ka jawaab mil gaya hoga 🤝 💚
❤ thankful to you sir!
Bhai aap konsi company mei kaam krte hai?
Tran paikege me thermostate ke Sath resistance kaise lagate hain
kon sa resistance aur kis liye ..?
Mein ne kabhi koi ac mein liquid charge nahin ki
Alhamdulillah koi masla nahin hui
i agree brother lekin sahi aur galat ko main agar sahi ko choose kiya jaye to kya nuksan hoga
R410 gas Two gas sa mil Kar Bana hata hai R32 r125 isliye ham liquid charge karta hai r410 ko ham tapap nahin kar sakte hain kyunki hamare system mein gas liquid charge kiye Hain liquid se vaparr banaa hai aur kaun sa gas Kitna release ho Gaya humko yah Nahin pata hai isliye ham 410 gas ko top up nahin kar sakte hain
fifty - fifty Right and Wrong ..
very important topic yaad dilaya hai aap ne 🤝
main is topic par ek video bana kar explain karoonga ...
R410 ko cylinder ulta kr ke kyo charge krte hai
Yes
video isi topic par hai ...
Bhaiya ji kam sikhana hai kaise sampark Karen
Bro pls go slow and don't repeat again again same thing....
ok brother 💚..
but as teaching this is normal 🙏